Units: kg / LB...................16 Time and Date Setting..............16 SPECIAL MODES..................17 Multiple Weigh.................17 Weight Gains...................18 AUTO-DRAFTING.................19 Using the Iconix Auto-Draft Controller..........19 ELECTRONIC ID (EID)................21 EID Set-Up Options.................21 Drafting By EID................22 EID / VID Cross Reference Table...........23 Planning an EID based System............24...
It is not recommended that the battery charger be left plugged into the indicator for long periods of time. To display the battery voltage, press the ENTER key while the FX41 is in the normal operating mode. The voltage should be in the range 12.6 to 13.2V for a fully charged battery.
The record consists of: Weight, Group, Date, ID (if used), Condition Code (if used) If an Iconix FX Printer is attached, the record will be printed. In the event of a problem with the weighing, press DELETE to delete the new record from memory.
While the Count Delay is in progress, "HOLDING..." is displayed. To extend the hold time for as long as the operator wishes, press the key (remember verride). When ready to release the animal, press the ENTER key (or any other key). Page 6 FX41 User Manual 08May08...
WEIGH is pressed. A record consists of : Weight, Group, Date, ID (if used), Condition Code (if used) The FX41 has an in-built clock-calendar and the date is automatically recorded every time WEIGH is pressed. In normal operation, before starting a new weighing session, the operator would select a previously unused group from the range 1 –...
Use a separate group file for each new weighing session on a different day. Use a separate group file for different categories of animal. Keep careful notes on the use of the group file numbers. Page 8 FX41 User Manual 08May08...
NOTE: Draft stats not available for DRAFT BY WEIGHT GAIN or DRAFT BY GAIN/DAY For the average weight gain (in average number of days) and average daily weight gain of the mob: Press *WGT GAIN AVG 23.0kg 62 DAYS GAIN/DAY = 0.371kg FX41 User Manual 08May08 Page 9...
The Iconix FX Printer is a rugged, portable printer that uses standard adding machine paper rolls. It is powered from the internal battery of the FX41 indicator. Note that use of the printer reduces the number of hours of operation before recharging is required.
The record details are displayed in the same way as for scrolling by ID (see above). The “NONE HIGHER” and “NONE LOWER” messages indicate that the highest and lowest record weights have been reached in the currently selected group. To exit from the memory search, press ENTER. FX41 User Manual 08May08 Page 11...
The FX41 is factory set to a baud rate of 19200 for the speedy transfer of records to the computer. If there is a particular need to change this setting, go into SET-UP and select from the range 1200, 2400, 4800, 9600, 19200 and 38400.
WEIGH is pressed: BELOW MIN. WEIGHT CANNOT STORE RECORD Step on to MAXIMUM WEIGHT by pressing DRAFT LIMITS or ENTER. Example: MAXIMUM WT = 600.0 OK=(ENTER), or NEW # FX41 User Manual 08May08 Page 13...
Automatic Drafting Option When the Auto-Draft option is enabled in SET-UP, an additional setting for Drafting Direction appears when the DRAFT LIMITS key is pressed. See Section 10: AUTO- DRAFTING for full details. Page 14 FX41 User Manual 08May08...
All set-up parameters are stored in permanent memory. NOTE : Ensure that the correct set of loadbars or platform is connected to the FX41 indicator before attempting to change any set-up parameters. There are three possible scale types that are automatically recognised when plugged in, as shown by the Scale 1,2,3 annunciators on the right of the display.
Selecting DRAFT / EID ON-LINE still allows a computer to be connected. The Iconix FX Printer, Iconix Auto-Draft Controller or an EID Reader are all connected via the 25 pin “OPTIONAL I/O” socket. This is a dedicated port for these devices. It is possible to run an Auto-Draft Controller and EID Reader simultaneously - Iconix can provide a special adaptor cable for this purpose.
When drafting statistics are calculated, the average animal weight in each multiple weighing record is compared with the draft limits and the Count from that record added to the High, Centre or Low numbers. FX41 User Manual 08May08 Page 17...
Auto Weight Gain Mode In AUTO weight gain mode, the FX41 searches through all records in memory for the most recent previous weighing of the animal just weighed. For a match the record must have the same non-zero ID number and the most recent date (but not the current date).
TRIGGER = EXTERNAL. In the case of the Racewell crate, a signal is sent from the crate to the FX41 when the clamping of the sheep occurs. Similarly for a cattle crate fitted with a microswitch that closes when the "IN gate" has been closed, automatic starting of the weigh cycle can be achieved.
Page 21
On exit, all gates will be left in the closed state. Note that if the override feature is used to send animals in a different direction from that indicated by FX41, then the draft statistics will not be the same as the number of animals physically drafted through each gate.
11. ELECTRONIC ID (EID) EID SET-UP OPTIONS The FX41 provides the flexibility to handle a range of EID applications. A summary of the EID set-up menus follows: 1. In SET-UP, first select PREFIXING = OFF. Prefixing is not compatible with EID.
Controller. An animal may optionally be weighed first, before it is drafted according to the direction in the pre-loaded file. 1. Use the WinFX linker program to download the EID drafting file to the FX41. Full details on this are provided in the on-line help in WinFX.
EID / VID CROSS REFERENCE TABLE The FX41 may be set up with a cross reference table supplied by a computer, using the Iconix WinFX Linker Package, or scanned/entered manually. The cross-reference table has a maximum of 3000 entries. Each entry in the table has 2 components:...
WinFX can be used for downloading a cross-reference table from the PC to the FX41. Note that if this is done, the FX41 will add the cross-reference entries to those already in memory. First decide whether to clear the existing cross-reference table in the FX41.
..19V DC Reverse polarity protection diode fitted. Low Battery Indication: Below 11.8 Volts the LOW BAT pointer s will be on. The FX41 switches off at approximately 10.5 Volts. Supply Current: Approximately 160 mA including loadbar set. Temperature Range: -5ºC to +50ºC...
Page 27
STEEL LOADBAR SET 2000KG BOTTOM LOADBAR DIMENSION LOAD LOAD AREA AREA 600 mm 1000 mm HEAVY DUTY LOADBAR SET 3000KG Ø Length 1000 Width Height Ø BOTTOM Page 26 FX41 User Manual 08May08...
Need help?
Do you have a question about the FX41 and is the answer not in the manual?
Questions and answers
how much is this?
The price of the Iconix FX41 is $1499.00 NZD plus GST.
This answer is automatically generated