4. Installation Instructions

Installation Steps:
1. Place and mount the BBINT50A, see chapter 5
2. Connect the BBINT50A, see chapter 6
3. Configure the BBINT50A, see chapter 7
CAUTION
Read the entire manual before installing the BBINT50A. Keep the manual in a safe location
for future reference.
Operating temperature range: -20 up to +60 ºC, >40 ºC derating power
[-4 up to +140 ºF, >40 ºF derating power].
Never use the BBINT50A at a location where there is danger of gas or dust explosions.
Never Mount the BBINT50A in such a way that airflow through the heatsink is
obstructed. This device requires a minimum of 10cm of clearance on every side.
Do not install the BBINT50A in the same compartment as gassing batteries. Do not mount
in the same area as batteries that might release corrosive sulphur fumes or explosive gasses.
Be sure that the output of the supplying source is switched off during installation. Also be sure
that no load is connected to the batteries during installation, to prevent hazardous situations.
Use cables with an appropriate size, see the following table.
Models
BBINT50A
Min. 3 Nm – max. 5 Nm
Recommended cable sizes DC input/output
Minimum cable size Input
16 mm2 [AWG 6]
10
Minimum cable size Output
16 mm2 [AWG 6]