  • Page 1 User Manual ® NanoVi Wellness Devices Household Device Eng3 Corporation English M004W-rev18...
  • Page 3 M004W-rev18 Copyright © 2022, Eng3 Corporation. All rights reserved. No part of this publication may be reproduced, copied, stored in a retrieval system, or transmitted, in any form or by any means without the prior written permission of Eng3 Corporation.
  • Page 5: Table Of Contents

    10 Cleaning Instructions ....................................21 11 Maintenance ........................................ 21 12 Storage ........................................21 13 Explanation of Symbols ....................................22 ® 14 Disposal of NanoVi Wellness Device and Parts ............................23 15 Troubleshooting ......................................24 Normal Operation ....................................24 Errors ......................................... 24 16 Electromagnetic compatibility ..................................
  • Page 7: Device Description

    The NanoVi Wellness device is designed to assist the natural process of creating ordered water layers (EZ Water) on proteins. NanoVi Wellness devices expose the humidified air stream to specific wavelengths. These wavelengths also include wavelengths that are similar (= bioidentical) to the emitted wavelengths of the reactive oxygen species (ROSs) that occur in the water of cells.
  • Page 8: Intended Use

    Precautions ® Read the User Manual carefully before using the NanoVi Wellness device for the first time. • Refer to the User Manual whenever questions or uncertainties arise with respect to correct handling of the NanoVi ® Wellness device. • Before use, make sure that the water level in the container is between the maximum and minimum levels marked on the container.
  • Page 9: Device And Accessory Precautions

    • If the power cord is damaged or the casing of the power supply is cracked or damaged in any way, DO NOT USE IT. • Always use the power supply (power adapter) provided by Eng3. Operation is restricted to 12V DC at the device input. If the origi- nal power adapter is defective or lost, only replace it with a power supply provided by Eng3.
  • Page 10: Set Up

    Follow these steps to set up your device: Use indoors, away from wet/splash/drips, between 59°F (15°C) to 104°F (40°C). ® Place the NanoVi Wellness device on a clean, solid surface. Rinse glass container using distilled, purified or osmotic water. Fill the container with distilled, purified or osmotic water. Make sure the water is between the maximum and minimum filling levels on the container.
  • Page 11: Operating Instructions

    Do not force the humidifier into the device; it will fit firmly. ® Connect the power cord to the power supply. Plug the power supply into the NanoVi Wellness device. Note Figure 1.2 to locate the power connector on the back of the device. Plug the power cord into an electrical outlet.
  • Page 12: Power On

    Wellness Eco device. As a result, a chosen session time for example of 15 minutes with the Exo device is similar to 30 minutes with the Pro device, or 60 minutes with the Eco device. ® It is recommended that users start using the device in short increments of time, in order to become familiar with the operation of the NanoVi ® ®...
  • Page 13: Session Running

    Operating without Smartcards: Standard-Mode only ® All the NanoVi Wellness devices can be operated without SmartCards. This operation is called Standard-Mode. In Standard-Mode everyone has access to sessions of any duration. Once the device is turned on, the initial “Splash”-Screen (Fig. 7.1) appears. A self-test runs for 10 seconds with progress shown by the bar at the bottom of the screen.
  • Page 14 Display shows session time Start Button Device ID # Fig. 7.2: “Start”-Screen in Standard Mode The Start Button starts the session, and the “Session in Progress”-Screen (Fig. 7.3) is shown. Rotating dots to the left indicate that a session is in progress. The session time display counts down the minutes and seconds remaining in the session. Pause Button interrupts a session (Fig.
  • Page 15: Operating With Smartcards

    Operating with SmartCards The Owner Card can be used by the device owner to access the four “Administration”-Screens. Insert Owner Card when the monitor shows the self-test is finished in the Initial “Splash”-Screen and the monitor has changed to one of the three “Start”...
  • Page 16: Standard-Mode: Select With The Owner Card And Operate Without User Card

    Standard-Mode: Select with the Owner Card and operate without User Card Selecting: Standard-Mode Standard Mode: all selectors are blank To select Standard Mode, all three buttons must be deselected, so that no orange dot appears, as shown to the right. Press the buttons to toggle between orange dot and no dot.
  • Page 17: User-Card-"Timer"-Mode: Select With Owner Card And Operate With User Card

    User-Card-"Timer"-Mode: Select with Owner card and operate with User Card Selecting: User-Card-"Timer"-Mode To select the User-Card-"Timer"-Mode, the lower button must show an orange dot. Press the button to toggle between orange dot and no dot. Button for User-Card- Timer"-Mode When the mode selector button is orange (Fig. 8.6), press the button “Page up”...
  • Page 18: User-Card-"Preset"-Mode: Select With The Owner Card And Operate With User Card

    User-Card-“Preset”-Mode: Select with the Owner Card and operate with User Card The device can be set up with a predetermined session time. In this case the session time cannot be freely chosen, only shortened, or paused. Input keys and display of the Selecting: User-Card-“Preset”-Mode preset session time To select the User-Card-“Preset”-Mode, the top and the lower selector...
  • Page 19: Programming User Cards

    Programming User Cards The Owner Card is used to program minutes onto the User Cards or delete minutes from the User Card. The Owner Card, the User Card, and the device must have the same ID#. Page down button goes to “Programing”-Screen The maximum number of minutes a User Card can be programmed to is 9,999 minutes.
  • Page 20: Use With Accessories

    Simply switch the extra glass container with the container that has water and tighten the lid for transport. The NanoVi Wellness device can remain in the transportation case during operation. 3: The case has two wheels and a pullout / retractable handle.
  • Page 21: Cleaning Instructions

    Device ® Clean the outside of the NanoVi Wellness device with a moist soft cloth, never use more than a mild detergent. Multiple cleanings with this method will not affect the device.
  • Page 22: Explanation Of Symbols

    13 Explanation of Symbols Symbol Title Direct Current Symbol Class II Electrical Equipment Type BF Applied Part Operating Instructions available on shown website www.eng3corp.com/eIFU “ON” / ”OFF” Article Number Serial Number Manufacturer Date of Manufacture Keep Dry Protected against solid foreign objects of 12,5 mm Ø and greater Center Pin Positive Owner of waste electronic equipment must recycle...
  • Page 23: Disposal Of Nanovi Wellness Device And Parts

    ® 14 Disposal of NanoVi Wellness Device and Parts Follow local governing ordinances and recycling plans regarding the recycling or disposal of the equipment. Refer to the Technical Specifica- tions in Section 16 for the materials of the main components for reference for sorting parts for disposal.
  • Page 24: Troubleshooting

    Firmware Fig. 15.1 “Error”-Screen Error codes are below and should be given to Eng3 Customer Support when you call. Use the number of the error message screen to reach ® technical support for the NanoVi Wellness device.
  • Page 25: Electromagnetic Compatibility

    Guidance and manufacturer‘s declaration - electromagnetic emissions ® ® The NanoVi Wellness is intended for use in the electromagnetic environment specified below. The customer or the user of the NanoVi Wellness should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment –...
  • Page 26 Guidance and manufacturer‘s declaration - electromagnetic immunity ® ® The NanoVi Wellness is intended for use in the electromagnetic environment specified below. The customer or the user of the NanoVi Wellness should assure that it is used in such an environment. Immunity test...
  • Page 27: Recommended Separation Distances

    TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an ® electromagnetic site survey should be considered. If the measured field strength in the location in which the NanoVi Wellness is used exceeds the applicable ®...
  • Page 28: Product Specifications And Registrations

    17 Product Specifications and Registrations Technical Specifications...
  • Page 29: Product Registrations

    Product Registrations ® NanoVi Wellness Registration: EU ® All NanoVi Wellness devices carry the mark represented in the declaration below.
  • Page 30: Warranty

    Eng3’s obligations under this warranty are limited to repairs, or at Eng3’s option, replacement of any defective parts or of equipment without charge, if defects occur during normal usage.
  • Page 31: Appendix A: Accompanying Documents

    22 Appendix A: Accompanying Documents Power Supply (2-Prong), Part # TR60M12-01E12 User’s Manual The input and output should not exceed the rating on the label. The 2-prong power supply should be operated only in dry conditions. Manufacturer: DongGuan Cincon Electronics Limited Factor Address: No.