Summary of Contents for Eng3 NanoVi

  • Page 1 User Manual ® NanoVi Devices Medical Device Eng3 Corporation English M004M-rev16...
  • Page 3 M004M-rev16 Copyright © 2021, Eng3 Corporation. All rights reserved. No part of this publication may be reproduced, copied, stored in a retrieval system, or transmitted, in any form or by any means without the prior written permission of Eng3 Corporation.
  • Page 5: Table Of Contents

    16.2.1 NanoVi® Registration: FDA ............................... 26 16.2.2 NanoVi® Registration: EU ..............................27 16.2.3 NanoVi® Cannula Registration: EU ........................... 28 16.2.4 NanoVi® Cannula Registration: FDA ..........................29 17 Warranty ........................................30 18 Service Policy ......................................30 19 Ordering Parts and Accessories .................................. 30 20 Contact Information .....................................
  • Page 7: Device Description

    ® the emitted wavelengths of the reactive oxygen species (ROSs) that occur in the water of cells. The wavelengths / signals from the NanoVi are emitted to water in a humidified air stream, which strengthens the coherent domains of the water molecules, and which are then transmitted to the user via the humid air stream.
  • Page 8: Intended Use

    Read the User Manual carefully before using the NanoVi ® device for the first time. • Refer to the User Manual whenever questions or uncertainties arise with respect to correct handling of the NanoVi ® device. • Before use, make sure that the water level in the container is between the maximum and minimum levels marked on the container.
  • Page 9: Device And Accessory Precautions

    • If the power cord is damaged or the casing of the power supply is cracked or damaged in any way, DO NOT USE IT. • Always use the power supply (power adapter) provided by Eng3. Operation is restricted to 12V DC at the device input. If the origi- nal power adapter is defective or lost, only replace it with a power supply provided by Eng3.
  • Page 10: Set Up

    Follow these steps to set up your device: Use indoors, away from wet/splash/drips, between 59°F (15°C) to 104°F (40°C). ® Place the NanoVi device on a clean, solid surface. Rinse glass container using distilled, purified or osmotic water. Fill the container with distilled, purified or osmotic water. Make sure the water is between the maximum and minimum filling levels on the container.
  • Page 11: Operating Instructions

    Confirm that there is a proper connection between the humidifier and the device. Do not force the humidifier into the device; it will fit firmly. Connect the power cord to the power supply. Plug the power supply into the NanoVi ®...
  • Page 12: Nasal Cannula - Optional, Non-Mandatory

    Flex-Arm. For proper use of the nasal cannula, refer to Appendix A: Accompanying Documents, User Manual for Nasal Cannulas. The NanoVi ®...
  • Page 13: Application Schedule

    15 minutes with the Exo device is similar to 30 minutes with the Pro device, or 60 minutes with the Eco device. ® It is recommended that users start using the device in short increments of time, in order to become familiar with the operation of the NanoVi ®...
  • Page 14: Operating Without Smartcards: Standard-Mode Only

    Operating without Smartcards: Standard-Mode only All the NanoVi ® devices can be operated without SmartCards. This operation is called Standard-Mode. In Standard-Mode everyone has access to sessions of any duration. Once the device is turned on, the initial “Splash”-Screen (Fig. 7.1) appears. A self-test runs for 10 seconds with progress shown by the bar at the bottom of the screen.
  • Page 15: Operating With Smartcards

    Operating with SmartCards The Owner Card can be used by the device owner to access the four “Administration”-Screens. Insert Owner Card when the monitor shows the self-test is finished in the Initial “Splash”-Screen and the monitor has changed to one of the three “Start”...
  • Page 16: Standard-Mode: Select With The Owner Card And Operate Without User Card

    8.3.1 Standard-Mode: Select with the Owner Card and operate without User Card Selecting: Standard-Mode Standard Mode: all selectors are blank To select Standard Mode, all three buttons must be deselected, so that no orange dot appears, as shown to the right. Press the buttons to toggle between orange dot and no dot.
  • Page 17: User-Card-"Preset"-Mode: Select With Owner Card And Operate With User Card

    8.3.3 User-Card-"Preset"-Mode: Select with Owner card and operate with User Card Selecting: User-Card-"Preset"-Mode To select the User-Card-"Preset"-Mode, the lower button must show an orange dot. Press the button to toggle between orange dot and no dot. When the mode selector button is orange (Fig. 8.6), press the button Button for User-Card- “Page up”...
  • Page 18: User-Card-"Preset"-Mode: Select With The Owner Card And Operate With User Card

    8.3.4 User-Card-“Preset”-Mode: Select with the Owner Card and operate with User Card The device can be set up with a predetermined session time. In this case the session time cannot be freely chosen, only shortened, or paused. Input keys and display of the Selecting: User-Card-“Preset”-Mode preset session time To select the User-Card-“Preset”-Mode, the top and the lower selector...
  • Page 19: Programming User Cards

    Programming User Cards The Owner Card is used to program minutes onto the User Cards or delete minutes from the User Card. The Owner Card, the User Card, and the device must have the same ID#. Page down button goes to “Programing”-Screen The maximum number of minutes a User Card can be programmed to is 9,999 minutes.
  • Page 20: Use With Accessories

    Use with Accessories Transportation Case...
  • Page 21: Cleaning Instructions

    Do not perform cleaning, servicing, or maintenance when the device is in use. Only perform cleaning, servicing, or maintenance when the device is powered off and not in use. Device Clean the outside of the NanoVi ® device with a moist soft cloth, never use more than a mild detergent. Multiple cleanings with this method will not affect the device.
  • Page 22: Explanation Of Symbols

    Explanation of Symbols Symbol Title Direct Current Symbol Class II Electrical Equipment Type BF Applied Part Operating Instructions available on shown website www.eng3corp.com/eIFU “ON” / ”OFF” Article Number Serial Number Manufacturer Date of Manufacture Keep Dry Protected against solid foreign objects of 12,5 mm Ø and greater Center Pin Positive Owner of waste electronic equipment must recycle...
  • Page 23: Disposal Of Nanovi ® Device And Parts

    ® Disposal of NanoVi Device and Parts Follow local governing ordinances and recycling plans regarding the recycling or disposal of the equipment. Refer to the Technical Specifica- tions in Section 16 for the materials of the main components for reference for sorting parts for disposal.
  • Page 24: Troubleshooting

    The contact number for your location will be displayed here Fig. 15.1 “Error”-Screen Error codes are below and should be given to Eng3 Customer Support when you call. Use the number of the error message screen to reach technical support for the NanoVi ®...
  • Page 25: Product Specifications And Registrations

    Product Specifications and Registrations 16.1 Technical Specifications...
  • Page 26: 16.2 Product Registrations

    Exo devices are registered with the United States Food and Drug Administration (FDA). FDA Device Listing number: D097353 FDA Facility Registration number: 3004152208 FDA Device Listing: © Copyright 2016 Eng3 Corporation. All rights reserved. M128-rev06 877.571.9206 | www.eng3corp.com | info@eng3corp.com...
  • Page 27: Nanovi® Registration: Eu

    ® 16.2.2 NanoVi Registration: EU ® All NanoVi devices carry the mark represented in the declaration below.
  • Page 28: Nanovi® Cannula Registration: Eu

    ® 16.2.3 NanoVi Cannula Registration: EU 0086 0086 0086 DECLARATION OF CONFORMITY 0086 DECLARATION OF CONFORMITY Salter Labs Salter Labs TF1005 Oxygen Cannulas 30 Spur Drive TF1005 Oxygen Cannulas 30 Spur Drive El Paso, Texas 79906 El Paso, Texas 79906...
  • Page 29: Nanovi® Cannula Registration: Fda

    ® 16.2.4 NanoVi Cannula Registration: FDA...
  • Page 30: Warranty

    Eng3’s obligations under this warranty are limited to repairs, or at Eng3’s option, replacement of any defective parts or of equipment without charge, if defects occur during normal usage.
  • Page 31: Appendix A: Accompanying Documents

    Appendix A: Accompanying Documents User Manual for Optional, Not-Mandatory Nasal Cannula Modell # 1600-1 21.1...
  • Page 32: 21.2 Power Supply (2-Prong), Part # Tr60M12-01E12

    21.2 Power Supply (2-Prong), Part # TR60M12-01E12 User’s Manual The input and output should not exceed the rating on the label. The 2-prong power supply should be operated only in dry conditions. Manufacturer: DongGuan Cincon Electronics Limited Factor Address: No. 1 Jingxiang Rd. Dongcheng Foreign Trade Industrial Park, Zhushan Dong Cheng District, Dong Guan, Guangdong, China The 2-prong power supply requires a 2-prong power cord.

This manual is also suitable for:

Nanovi ecoNanovi proNanovi exo