Grant Vortex
Outdoor Module / External
Condensing Oil Boiler Range
User Instructions
IRL | DOC 0019 | Rev 02.00 | October 2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VORTMOD1526P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Grant VORTMOD1526P

  • Page 1 Grant Vortex Outdoor Module / External Condensing Oil Boiler Range User Instructions IRL | DOC 0019 | Rev 02.00 | October 2022...
  • Page 2 This manual is accurate at the date of printing but will be superseded and should be disregarded if specifi cations and/or appearances are changed in the interests of continued product improvement. However, no responsibility of any kind for any injury, death, loss, damage or delay however caused resulting from the use of this manual can be accepted by Grant Engineering (Ireland) ULC, the author or others involved in its publication.
  • Page 3: Table Of Contents

    CONTENTS INTRODUCTION About your boiler Boiler controls access What the installer should leave you with Commissioning Activating the guarantee Boiler servicing Boiler data plate USING YOUR BOILER Lighting your boiler If your boiler fails to light Turning off your boiler About your fuel Boiler controls Heating system controls...
  • Page 4: Introduction

    In order for your boiler’s full* guarantee to be activated, your boiler on’ neon, see Figure 1-1, which lights when the boiler is switched must be registered with Grant within 30 days of its installation. To register your boiler, please ensure the completed boiler...
  • Page 5: Boiler Data Plate

    To restart, refer to Section 2.1 (Lighting your Boiler). ABOUT YOUR FUEL Grant Vortex module boilers only operate on Class C2 Kerosene to BS 2869:1998. You should always quote this type of fuel when ordering from your supplier.
  • Page 6: Heating System Controls

    fi tted in, take care not to cover the If a Grant Vortex External Sealed System Kit is fi tted, this safety TRV head (with curtains, furniture etc).
  • Page 7: How To Fill Or Top Up Your Sealed System

    The pressure gauge on the system does not show the air charge pressure in the expansion vessel. ! NOTE ! In order to properly care for your Grant boiler, an annual service by a compentant person should always be undertaken.
  • Page 8: Failure Of Electricity Supply

    We recommend that both antifreeze and corrosion inhibitor work is carried out. be used in the primary water system. Costs incurred by unauthorised work will not be covered by Grant. To contact the Grant customer support team, please call: 00353 FAILURE OF ELECTRICITY SUPPLY 5791 20089.
  • Page 9: Service Log

    SERVICE LOG Date Date Engineer Engineer Company name Company name Telephone number Telephone number OFTEC Technician number OFTEC Technician number Comments Comments Signature Signature Date Date Engineer Engineer Company name Company name Telephone number Telephone number OFTEC Technician number OFTEC Technician number Comments Comments Signature...
  • Page 10 Date Date Engineer Engineer Company name Company name Telephone number Telephone number OFTEC Technician number OFTEC Technician number Comments Comments Signature Signature Date Date Engineer Engineer Company name Company name Telephone number Telephone number OFTEC Technician number OFTEC Technician number Comments Comments Signature...
  • Page 11: Notes

    NOTES Notes Page 11...
  • Page 12 GRANT ENGINEERING (IRELAND) ULC Crinkle, Birr, Co. Off aly, R42 D788, Ireland Tel: +353 (0)57 91 20089 Email: info@grantengineering.ie www.grant.eu...