Tema Telecomunicazioni AD630S Programming Manual

Tema Telecomunicazioni AD630S Programming Manual

Voip sip 30w poe horn speaker
Hide thumbs Also See for AD630S:

Advertisement

Quick Links

AD630S / AD630SA
IP66 grade of protection – 120dB – 2 Way
FOR THE HARDWARE INSTALLATION OF THE DEVICES, REFER TO THE COMPLETE MANUAL
Products for VoIP SIP LAN networking Communications, Paging Amplifiers Systems and Audio
Applications. Zone Announcements, Night Ringer, Multicast general call, Background music,
Standard SIP call or Emergency call, SD memory with pre-recorded messages, Relays for LAN
drives.
Revision
Date
0
19/04/2022
TEMA TELECOMUNICAZIONI
"IP COMMUNICATION AND SECURITY COMPANY"
WWW.TEMATLC.IT
VoIP SIP 30W PoE Horn Speaker
PROGRAMMING MANUAL
HW Version 1.0 – SW Version 1.1
Audio Over IP Network Series
Revision reason
First edition
Prepared
MM, DP
Cecked/Approved
DP, FL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AD630S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tema Telecomunicazioni AD630S

  • Page 1 TEMA TELECOMUNICAZIONI “IP COMMUNICATION AND SECURITY COMPANY” WWW.TEMATLC.IT AD630S / AD630SA VoIP SIP 30W PoE Horn Speaker IP66 grade of protection – 120dB – 2 Way PROGRAMMING MANUAL HW Version 1.0 – SW Version 1.1 FOR THE HARDWARE INSTALLATION OF THE DEVICES, REFER TO THE COMPLETE MANUAL...
  • Page 2: Table Of Contents

    AD630S/630SA VoIP SIP 30W / PoE Horn TEMA TELECOMUNICAZIONI INDICE PAGINA PROGRAMMING ............................3 1.1. P ................3 REPARATION FOR PROGRAMMING THE SYSTEM PARAMETERS 1.2. A ..........................4 CCESS TO PROGRAMMING 1.3. N .............................5 ETWORK PARAMETERS 1.4. SIP P .............................6 ARAMETERS 1.5. G ............................8...
  • Page 3: Programming

    Programming takes place through the WEB interface. To access, simply connect an Ethernet cable from a PC or switch to the LAN port of the AD630S. The system is supplied with active DHCP (dynamic setting of the network address) for which the IP address is automatically assigned by the local DHCP server.
  • Page 4: Access To Programming

    AD630S/630SA VoIP SIP 30W / PoE Horn TEMA TELECOMUNICAZIONI 1.2. Access to programming To program the device, it is sufficient to use a normal browser, such as Explorer, Firefox, Chrome or other. The user / password to connect with are master/master. Once logged in, it will be possible to change the administration password for maximum security of your device, see par.
  • Page 5: Network Parameters

    IP Address: indicate the IP address you want to assign to AD630S. • Subnet mask: indicate the network mask you want to assign to the AD630S. • Default gateway: indicate the gateway that can allow AD630S to access the internet.
  • Page 6: Sip Parameters

    Once the network parameters have been correctly set, the VoIP-SIP connection with the PBX must be configured: • SIP server address: indicate the IP address of the SIP switchboard to which the AD630S must connect. • Port: is the number of the SIP port of the PBX with which to forward incoming calls. Generally it is the 5060 but some stations use another port..
  • Page 7 AD630S/630SA VoIP SIP 30W / PoE Horn TEMA TELECOMUNICAZIONI Ringer Account User: this account is used for the Night Ringer group. In practice, it is possible to program • the switchboard to make a group of extensions ring in night mode. You can also put the device in this group, which will play the ring message without answering.
  • Page 8: General Settings

    Call attempt duration: establishes how long the internal call attempt should last, in seconds (if the called number rings but does not answer). • Response time: when the AD630S is called, it answers after the set time. If it is 0, it answers immediately, if 999 it never answers. •...
  • Page 9: Set Day/Night Mode

    AD630S/630SA VoIP SIP 30W / PoE Horn TEMA TELECOMUNICAZIONI 1.6. Set Day/Night mode It is possible to set the DAY / NIGHT mode manually or automatically by setting weekly time bands. On this page, the codes for changing the modes via remote telephone and the night time bands for the automatic mode are configured: •...
  • Page 10: Inputs

    AD630S/630SA VoIP SIP 30W / PoE Horn TEMA TELECOMUNICAZIONI 1.7. Inputs The device has 3 inputs, which can be configured as call buttons, alarm inputs or ringer: Each input can be configured separately: • Active function: indicates whether to check the input or ignore it.
  • Page 11 AD630S/630SA VoIP SIP 30W / PoE Horn TEMA TELECOMUNICAZIONI • Separation: valid in alarm mode. Separation, in seconds, between one call attempt and the next. • Delay: valid in alarm mode. Activation delay in seconds. It is used to cover any short-term events for which an alarm is not desired.
  • Page 12: Outputs

    AD630S/630SA VoIP SIP 30W / PoE Horn TEMA TELECOMUNICAZIONI 1.8. Outputs The standard device is equipped with 2 relay outputs (number 3 is valid only for special versions that require a change to the hardware): • Mode: sets the function to be associated with the output. You can choose between 1 –...
  • Page 13: Maintance

    AD630S/630SA VoIP SIP 30W / PoE Horn TEMA TELECOMUNICAZIONI 1.9. Maintance In this page it is possible to change / listen to the pre-recorded messages of “Alarm”, “Announcement” and “Ringtone”. The memory contains default messages for each of the positions, the messages can be customized by the user at will as long as the WAV PCM 8 kHz, 16 bit, mono format is used and that each message does not exceed 60sec in length.
  • Page 14: Multicast

    TEMA TELECOMUNICAZIONI 1.10. Multicast By activating this function, the AD630S will listen to the specified address / port, reproducing any received audio stream from the speaker. The function has a lower priority than the normal telephone operation of the system, i.e.
  • Page 15 AD630 in Master-Slave configuration for general telephone call on Multicast channels In the scenario shown, each AD630S can receive the telephone call and broadcast the announcement in its area, without prejudice to all the other programmable functions. The AD630S system configured as "MASTER" receives the telephone call and, in addition to broadcasting the announcement in its area, simultaneously generates a Multicast audio stream on a programmable channel and broadcasts the same announcement on all "SLAVE"...
  • Page 16: Automatic Announcements

    AD630S/630SA VoIP SIP 30W / PoE Horn TEMA TELECOMUNICAZIONI 1.11. Automatic announcements It is possible to program announcements at set times, which can take place on the local speaker or in streaming to other devices. Daily activation: it is possible to automate the issuance of a daily announcement (which will take place at the set time) for each day.
  • Page 17: Months , They Are Used By The Device To Index Within The Document )

    AD630S/630SA VoIP SIP 30W / PoE Horn TEMA TELECOMUNICAZIONI Periodic activation from file: you can upload a text file in "csv" format (therefore easily editable with Excel ") that contains, for each day of the year, up to 32 times in which to issue the announcement. To compile the file, simply download the default one...
  • Page 18: Autotest

    AD630S/630SA VoIP SIP 30W / PoE Horn TEMA TELECOMUNICAZIONI 1.12. Autotest To ensure the efficiency of the speaker, it is possible to set the self-test function, to be carried out once a day. In practice, the system automatically emits three acoustic tones on the speaker which are then reread and analyzed through the internal microphone.
  • Page 19: Diagnostic Log

    AD630S/630SA VoIP SIP 30W / PoE Horn TEMA TELECOMUNICAZIONI 1.13. Diagnostic Log To identify small configuration problems, it is possible to have a textual diagnostic relating to the activity of the VoIP channel of the device: It is also possible to perform a low-level network trace with the “dump” button. A file in pcap format readable with the Wireshark program will be created, freely downloadable from the web.
  • Page 20: Hardware Reference

    AD630S/630SA VoIP SIP 30W / PoE Horn TEMA TELECOMUNICAZIONI 2. HARDWARE REFERENCE 2.1. Connecting the internal module of AD630S Inside of AD630 there is an electronic module for the management of communication functions on the VoIP network, and for amplification of the audio signal. The connection of the signal cables from the field must be carried out by qualified technical personnel, operate verifying that no cable is under voltage, also strictly comply with the instructions of the voltage and current values for the power supplies and other parts of the system.
  • Page 21 AD630S/630SA VoIP SIP 30W / PoE Horn TEMA TELECOMUNICAZIONI 4-pin removable terminal block (screw connector inserted to the electronic module) +Vout Terminal block from which it is possible to withdraw unregulated power supply, POSITIVE Terminal block from which it is possible to withdraw unregulated power supply, NEGATIVE...
  • Page 22: Correct Connection Of An Additional Passive Speaker

    3,277 Ohm/Km SP - AD630S with additional passive speakers of the same design Thanks to the 2nd internal audio amplifier it is possible to connect to the active IP unit another 1 or 2 low-cost passive speakers of the same design to increase power, directionality, extend the area served, even in different rooms separated by walls, in order to reduce the cost of the plant.
  • Page 23: 100V Audio Line For Additional Speakers Away From Ad630S Ip Horn

    TEMA TELECOMUNICAZIONI 2.3. 100V audio line for additional speakers away from AD630S IP Horn For special applications it is possible to generate from AD630 an audio line at a constant voltage of 100V of max 20W power using a Tema AD320/30 transformer to connect on the SP1 power output. In this way it is possible to install several other additional speakers (with internal transformer suitable for 100V line and selectable power) even at distances up to 200 meters from AD630.
  • Page 24 AD630S/630SA VoIP SIP 30W / PoE Horn TEMA TELECOMUNICAZIONI Notes MAS-AD630S-REV00-Programming manual Page 24 of 24...

This manual is also suitable for:

Ad630sa

Table of Contents