S&P PCDXP Series Manual

S&P PCDXP Series Manual

Ventilation fan

Advertisement

Quick Links

MODEL: PCD80XHP
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the
manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning the unit, switch power off at service panel and lock the service discon-
necting means to prevent power from being switched on accidentally. When the service disconnect-
ing means cannot be locked, securely fasten a prominent warning device, such as a tag, to the
service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all
applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupt-
er) - protected branch circuit (ceiling installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further information and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting brush attach-
ment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the
exact service motor. The impeller should also be replaced.
OPERATION
See "Connect Wiring Diagram" for details.
The control box, located inside the fan housing, has two settings:
(1) The time delay knob sets the amount of time that the fan will continue to run at high speed
after switch is turned OFF, or the RH% limit is reached. It is adjustable from 5 to 60
minutes. Once the set time has elapsed, the fan will run at the Low speed. The time delay
setting is de-activated when set between OFF-5 mins (factory set to OFF). NOTE: for
humidity sensing applications, the fan will continue to run for 5 minutes after humidity is
below the RH% limit, even if the time delay knob is set between OFF-5 mins.
(2) The humidity sensor knob sets the RH% limit at which the fan will automatically operate at
high speed. The humidity sensor is de-activated when set between OFF-30% .
Operation Sequence
1. Turn power ON. The fan will run at low speed (40 CFM)and the humidity sensor will start sensing .
2. Turn switch ON. The fan will run at high speed(80 CFM) and will override the humidity sensor.
3. Turn switch OFF. The fan will continue to run at high speed until the time delay has elapsed (if enabled), and then will automatically change back
to low speed.
HUMIDITY SENSOR OPERATION
The fan runs continuously at a low speed and automatically boosts up to high speed when the relative humidity (RH%) in the room exceeds the RH%
limit set with the humidity sensor knob. If the fan continuously responds to changing environmental conditions (too sensitive), the RH% limit may need
to be adjusted.
Installer: Leave this manual with the homeowner.
READ AND SAVE THESE INSTRUCTIONS
VENTILATION FAN
45%
20min
60%
30%
5min
OFF
OFF
80%
H
Time delay knob
Humidity sensor knob
40min
60min
T
Cod: 0060300000-A

Advertisement

loading

Summary of Contents for S&P PCDXP Series

  • Page 1 VENTILATION FAN MODEL: PCD80XHP WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2.
  • Page 2 OPERATION SENSITIVITY ADJUSTMENT The “H” limit has been factory set for most shower applications. However, if the fan is in a tub area or is being used for moisture control, the “H” may need to be increased toward 80%. If the fan is responding too often to changing environmental conditions, the “H” setting may need to be increased toward 80%.
  • Page 3 ASSEMBLY INSTRUCTIONS 4. Install DUCT AND BLOWER ASSEMBLY Hole a. Install duct from the inside of the housing; Fix the duct by the tab. b. Fix the BLOWER ASSEMBLY to the housing by 3 screws. Hole Hole 5. INSTALL ROUND DUCTWORK a.
  • Page 4 INSTALL GRILLE Install ceiling material to complete the ceiling construction and cut around the fan housing. To attach the grille assembly to the fan housing, pinch the grille springs on the sides of the grille assembly and position the grille into the housing with the grille springs in the appropriate slots. Push the grille assembly towards the ceiling to secure.