Sl280Dfv Gas Furnace; Shipping And Packing List; Safety Information - Lennox SL280V Installation Instructions Manual

Table of Contents

Advertisement

SL280DFV Gas Furnace

The SL280DFV gas furnace is equipped with a two−stage,
variable speed integrated control. the control is compat-
ible with:
Communicating thermostats − icomfort Touch
Non−communicating thermostats − ComfortSense or oth-
er conventional thermostats.
Control systems − Harmony III™ Zone Control System
(non−communicating). Each SL280DFV unit is shipped
ready for installation in the downflow position.

Shipping and Packing List

Package 1 of 1 contains
1 − Assembled SL280DFV unit
1 − Bag assembly containing the following:
2 − Screws
1 − Snap bushing
1 − Snap plug
1 − Wire tie
1 − Vent warning label
1 − Owner's manual and warranty card
The following items may be ordered separately:
1 − Thermostat
1 − Propane/LP changeover kit
1 − Combustible flooring base
Check equipment for shipping damage. If you find any
damage, immediately contact the last carrier.

Safety Information

DANGER
Danger of explosion.
There are circumstances in which odorant used with
LP/propane gas can lose its scent. In case of a leak,
LP/propane gas will settle close to the floor and may
be difficult to smell. An LP/propane leak detector
should be installed in all LP applications.
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, person-
al injury or loss of life. Installation and service must
be performed by a licensed professional installer (or
equivalent), service agency or the gas supplier.
As with any mechanical equipment, personal injury
can result from contact with sharp sheet metal
edges. Be careful when you handle this equipment.
®
.
Certifications
SL280DFV units are CSA International certified.
In the USA, installation of gas furnaces must conform with
local building codes. In the absence of local codes, units
must be installed according to the current National Fuel
Gas Code (ANSI-Z223.1). The National Fuel Gas Code is
available from the following address:
American National Standards Institute, Inc.
11 West 42nd Street
New York, NY 10036
Clearances
Adequate clearance must be made around the air open-
ings into the vestibule area. In order to ensure proper unit
operation, combustion and ventilation air supply must be
provided according to the current National Fuel Gas Code.
Vent installations must be consistent with the venting
tables (in this instruction) and applicable provisions of local
building codes.
This furnace is CSA International certified for installation
clearances to combustible material as listed on the unit
nameplate and in the tables in figure 13. Accessibility and
service clearances must take precedence over fire protection
clearances.
Installed Locations
For installation in a residential garage, the furnace must
be installed so that the burner(s) and the ignition source
are located no less than 18 inches (457 mm) above the
floor. The furnace must be located or protected to avoid
physical damage by vehicles. When a furnace is installed
in a public garage, hangar, or other building that has a haz-
ardous atmosphere, the furnace must be installed accord-
ing to recommended good practice requirements and cur-
rent National Fuel Gas Code.
NOTE − Furnace must be adjusted to obtain a temperature
rise (high and low fire) within the range(s) specified on the unit
nameplate. Failure to do so may cause erratic limit operation
and may also result in premature heat exchanger failure.
This SL280DFV furnace must be installed so that its electri-
cal components are protected from water.
Installed in Combination with a Cooling Coil
When this furnace is used with cooling units, it shall be
installed in parallel with, or on the upstream side of, cooling
units to avoid condensation in the heating compartment.
With a parallel flow arrangement, a damper (or other
means to control the flow of air) must adequately prevent
Page 4