QUICK MANUAL FOR USE AND INSTALLATION
The Quick Manual will guide you through a quick installation of the
product, but in no case could it replace the full operating manual. A
complete operating manual is available on our website www.xvent.cz
or can be downloaded using a QR code.
Use the smart device (mobile phone,
tablet, etc.) equipped with this
technology to read the QR code.
The regulator may only be
mounted and connected by a
trained person with the
appropriate authorization to
connect electrical equipment
with suitable tools and
means.
1.
Description of regulator
The regulator is used to continuously control the speed of the EC-motors with the control input 0-10VDC without connection to the mains
power supply. The motor speed is controlled continuously by the control element (a knob) on the front panel of the regulator. For information
on the operation of the connected equipment, the operating signal diode is located in the upper part of the front panel. The regulator is
supplied with direct voltage of 10 VDC from the EC-motor. The maximum recommended distance of the regulator from the regulated EC-
motor is 100 m, with conductor cross-section of 1 mm
cross section and calculation of real voltage loss.
Description of controls and connecting terminals
Signalling diode –signals operation of the entire
regulator. If the diode is lit, the regulator is on. If not, the
regulator is off.
Continuous fan speed regulator –allows continuous fan speed
setting in any position from minimum to maximum speed as
required by the user. The "OFF" position allows the entire
regulator to be switched off. The "OFF" position does not
provide disconnection of the controlled device from the supply
voltage –it must be performed separately on the supply voltage
of the controlled device.
Verze 001 (21.1.2020)
B - MARK I
. Possible increase or reduction of the distance according to the selected conductor
2
EC-fan connection terminals -
terminals for connecting the control voltage from the EC fan 0-
10VDC (+);
GND (-) with 10kΩ resistor. Regulator control range 2-10V
Contact load: max 0.3mA
Terminal clamp for regulator power supply -
clamp +10V intended for regulator power supply
Max. current capacity of regulator: 10mA
Recommended cross-section of conductors: from 0.5 mm
2.
Technical parameters
- Input voltage
- Output voltage - fan contro
- Protection
Stránka 1 z 2
Poděbradská 289
53009 Pardubice-Trnová
office@xvent.cz
2
to 1.5mm
10VDC
- Current
l 0-10VDC
- Dimensions
85 x 85 x 30 mm
IP20
- Weight
D-502-0167
Xvent s.r.o.
2
.
10mA
0.12kg

Advertisement

loading

Summary of Contents for Xvent eLEMENTAIR B-MARK I

  • Page 1 The Quick Manual will guide you through a quick installation of the product, but in no case could it replace the full operating manual. A complete operating manual is available on our website www.xvent.cz or can be downloaded using a QR code.
  • Page 2 Xvent s.r.o. Poděbradská 289 53009 Pardubice-Trnová office@xvent.cz LOCATION AND ASSEMBLY OF THE ELEMENTAIR CONTROLLER FRONT COVER DISASSEMBLY INSTALLATION ON UNDER-PLASTER OR ON SURFACE- MOUNTED ELECTRICAL JUNCTION BOX OF THE CONTROLLER ASSEMBLING THE CONTROL PANEL AFTER CONNECTING POWER SUPPLY AND CONTROL CABLES (ALIGN THE CABLE TO AVOID DAMAGE) Verze 001 (21.1.2020)