ancnoble FMP-Solar Manual

Flow meter, pressure meter, master valve, pump controller

Advertisement

Quick Links

Flow Meter, Pressure Meter,
Master Valve, Pump Controller
FMP-Solar
Manual
Version: 1.01
© 2016 ANC Technology
ANC Technology
www.anctech.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FMP-Solar and is the answer not in the manual?

Questions and answers

Summary of Contents for ancnoble FMP-Solar

  • Page 1 Flow Meter, Pressure Meter, Master Valve, Pump Controller FMP-Solar Manual Version: 1.01 © 2016 ANC Technology ANC Technology www.anctech.com...
  • Page 2: Table Of Contents

    1.General....................................2 2.Specification................................... 2 3.Function....................................3 4.How to install..................................3 4.1 Notes of installation:...............................4 4.2 Installation:..................................4 4.2.1 Pump connection illustration..........................4 4.2.2 How to install pressure sensor/switch......................... 6 4.2.3 Valve connection..............................7 4.3 How to do connection inside the connection box......................8 4.4 Printed instruction on the box:.............................
  • Page 3: 1.General

    1.General FMP-Solar controller controls pump and master valve, measures flow rate, and water pressure. Compatible with GG-002 WiFi / 3G wireless control system. Solar powered with water proof shell design, good for outdoor application. 2.Specification Solar Panel: 17.4V DC /220mA/3.8W (Support Extra panel) Back battery: 10*1.2V/ 2.3AH AA NiMH...
  • Page 4: 3.Function

    Valve specification: 1,Voltage:6-12VDC Pulse 2, Latching valve Pump control output:Open-(12VDC) Close-(0VDC) Controller box size:Long:28cm Wide:17.5cm High:28.2cm Controller box protective grade: IP56 3.Function 1,ASA weather proof shell design, water proof, for outdoor application 2,Solar powered, wireless, no need of power or communication lines in the field. 3,Solar panel is fixed on the shell.
  • Page 5: Notes Of Installation

    4.1 Notes of installation: 1,Make sure solar panel is face maximum sun. If there is not enough sun, add extra solar panel. 2 , For application of controlling pump and master valve, must install protective pressure sensor or pressure switch. If pump water from well, suggest to sue water position sensor to prevent pumping without water.
  • Page 6 How to install pump...
  • Page 7: How To Install Pressure Sensor/Switch

    4.2.2 How to install pressure sensor/switch Note: Because that the threaded end of pressure sensor and switch is very small, suggest using three way adaptor for small pipe, and drill hole to install for big pipe. When water pressure out of setup range, the controller will protectively shut off the pump or master valve.
  • Page 8: Valve Connection

    4.2.3 Valve connection For master valve, choose one of them as protective devices, pressure switch, pressure sensor, or flow meter. To mechanical pressure switch, must do tiny adjusting when water go through pipe, adjusting the screw until no alarms at normal situation. (Open water proof cap to do adjusting.
  • Page 9: How To Do Connection Inside The Connection Box

    There are only total 5 wireless flow meter controllers for one GG-002 WIFI/3G system. 4.3 How to do connection inside the connection box Turn off controller first. Check printed instruction at both beside of the controller, find the one you want to do connection. And pick out the related connector from the box. Unscrew and get ready.
  • Page 10 box. Step 4: According to printed instruction on the side of the box, connect the wires according to color, and screw tight. Step 5:Double check connection, put seal right, before put the connector back to box. Cover and tight up.
  • Page 11: Printed Instruction On The Box

    4.4 Printed instruction on the box: Extra solar panel+Flow meter Valve+Pressure Meter+Pressure switch Pump+Low Level switch+High level switch 5.How to operate 1. Solar panel 6.Battery 11. Manual valve key 2. LCD 7. Water proof connector 12. Enter/Save key 3. Key pad 8.
  • Page 12: How To Register To Gg-002Wifi/3G System Main Controller

    LCD will show as following, then into running. If the battery voltage is low, the controller will turn self off. If there is no sun to charge battery for some time, the battery voltage will reach low point, then controller will protectively shut down self , and automatically wake up after the battery is been recharged again.
  • Page 13 digital key 4 show“√”, which means the route is been established. You can check the route by browsing into help menu. This controller will automatically search route until success. Or push [Setting] key into main menu, then push [Exit] key to exit will produce one search, if there is no wireless communication route yet.
  • Page 14: How To Turn Off Controller

    main controller. Note 2: All field controllers need to found wireless route through relay to communicate with main controller, the relay route could be 1, 2, or 3 layers. Field controllers will report route to the main controller, the main controller then save this information and follow this route to communicate with field controllers.
  • Page 15: Field Manual Open/Close

    During sleeping, LCD show as following: 5.6 Field manual open/close 5.6.1 Field manual open/close During working status, push “valve” key , LCD show valve status as “Manual on” , the controller will open the master valve, and send current status to main controller. Push “valve”...
  • Page 16: Explanation Of Lcd Information

    After manually open the pump, LCD show as above. 05' ( time range is 00'-99')means manual open valve for 5 minutes. This function is for observing delay time needed for stabilizing flow rate and water pressure, then setup right delay time for alarm. And setup right flow and pressure range.
  • Page 17: Lcd Display For Protective Shut Down Of Pump

    This function is for fertilizing control by total flow volume. Customer setup first and second alarm volume from main controller or PC. For example, like 3 cubic meter and 4 cubic meter. Then, when the volume reached 3 cubic meter, first alarm on, it is time to start get ready to turn off the valve, when reached 4 cubic meter, second alarm on, it is time to turn off the fertilizing valve.
  • Page 18: Communication Window

    5.7.3 Communication window: During communication time between FMP-Solar and main controller, show as above. Then all the keys been locked up until communication finished. 5.7.4 Detail information windows During normal work status, push【1】 【2】 【3】 【4】digital keys switch for more work information.
  • Page 19 4. Pump status: Same as master valve. Push key【4】,showID/route and wireless signal strength System ID:FMP-Solar controller through registration to get ID from the main controller. All field controllers in one system have same ID. 2. Current battery status. Will show charging icon when is charging.
  • Page 20: 6.How To Setup

    4. Strength of wireless signal. Note:The controller will automatically turn off after 1 minute without any operation. Push any key to bring back. 6.How to setup This controller control one flow meter, one pressure sensor, one pump and one master valve. Each has setup menu.
  • Page 21: Register/Remove Flow Meter

    6.1.1 Register/Remove flow meter Browse into Reg(istration)/remove flow meter menu, There is current registration information as following. If not registered, will show “not registered”. Push【Menu】key to choose register or remove, push【Enter】key to execute. Registration: Any registration needs to do with main controller simultaneously. Both need to be at registering stage.
  • Page 22 During removing, FMP controller will try to communicate with main controller, but main controller is not at remove status. After FMP-Solar failed to reach main controller, push 【Exit】 will exit from registration, otherwise LCD will ask if you want to do “Local delete?”.
  • Page 23: How To Setup Flow Meter Coefficient Number

    Remove simultaneously: Remove registration information from main controller and FMP controller simultaneously. Let FMP controller get ready for remove same as above. When FMP controller start to search main controller, let main controller also into remove menu and get ready. Then the registration information will be removed from both simultaneously.
  • Page 24: How To Clear Total Flow Volume

    following; Push 【Menu】 key to choose between MIN and MAX,highlighted one is the one been chosen. Input digits, push 【Exit】key to delete one digit, less than 5 digits, push【Enter】 key to confirm. After done with edit MIN-MAX value, push【Enter】key to save and back to previous menu.
  • Page 25: Pressure Meter Setup

    6.2 Pressure meter setup Browse into “Set up pressure meter” menu: Reg/remover pressure meter—set up pressure range 2 choices as following: 6.2.1 Reg/remove pressure meter Reference 6.1.1 flow meter register and remove. 6.2.2 Setup pressure range (0 - 1Mpa) Reference 6.1.3 flow meter flow rate range setup. 6.3 Pump setup Browse into “Set up pump”...
  • Page 26: Register And Remove Pump

    6.3.1 Register and remove pump Reference 6.1.1 flow meter registration and remove. 6.3.2 Set up pump protection sensor Browse into “Set up pump” menu, there are Disable flow meter, Pressure meter, Liquid level switch 4 choices as following: In the Sensor option to choose, if choose 0, which means no protection for the pump. If choose like above, 1 and 2, which means choose flow meter and pressure sensor as protective sensors.
  • Page 27: Setup Pump Protective Time Delay

    water level, will protectively turn off the pump. Note:Sensor which is not been installed, make sure not been chosen in the protection setup. Otherwise the pump can’t operate normal. 6.3.3 Setup pump protective time delay Browse into“Safety detection delay”menu, LCD show current setup as following: Set up range is 1-99 minutes.
  • Page 28: How To Setup Detection Devices

    6.4.2 How to setup detection devices Browse into“Sensor options”menu,there are Non-Flow meter-Pressure meter-Water level 4 choices, choose 1, or up to 3 items as shown at following: If key in 0 beside “Sensor options=”, which means will not using any protective sensor. Choose either one of other 1,2,3, or any combination of these sensors, for example, choose 1, which means choose only flow meter as protective sensor for the pump.
  • Page 29: Setup Valve Open/Close Time Delay

    6.4.3 Setup valve open/close time delay Reference 6.3.3 pump delay time setup, which is similar. 6.5 Help 6.5.1 Questions and Answer Not setup yet. 6.5.2 Communication link Above illustration means direct communication with main controller, no any relay between them. If there are relays, will show relay devices with ID. If there is no communication route, will show as following:...
  • Page 30: How To Upgrade Wireless Field Controllers

    7. How to upgrade wireless field controllers 1. Preparation: First of all, power off the field controller which is waiting for upgrading, and prepare a newest version of wireless field controller standby (users can buy a latest wireless controller from ANC Technology, or send one old version wireless field controller to the manufacturer to upgrade to newest version, can be used to send newest version of program to old version of wireless field controller).
  • Page 31 upgrade process takes about a few minutes, please be patient. The upgrade process ensure greater than 2 meters, the distance between the two machines is less than the maximum distance to communication to ensure that the two controllers can communication normally, prevent the upgrade failed.
  • Page 32 Shanghai ANC Technology Limited Warranty card Dear Customer: Thank you very much for choosing ANC products. 1. This product has FCC verification. 2. Warranty period is one year. Beginning on day of receipt. 3. Please keep your receipt and this warrantee card. 4.

Table of Contents