3. Configure the SIM100 switch channel mode (indicated as "Channel #x Mode") to the "End of Line Resistor" setting. Please
refer to the SIM100 User's Manual for details.
4. Mount the Orbis Marine Smoke/Heat Detector and the Klaxon Sounder to their respective bases.
5. Supply power to the NMEA 2000
(normal) state using a Maretron display, N2KAnalyzer, or other product capable of displaying switch indicator state.
6. Perform a smoke test and heat test on the Orbis Marine Smoke/Heat Detector and verify that the switch channel indicates
an "on" (alarm) state and that the sounder generates the alarm sound during each of the tests.
7. Disconnect either of the two alarm wires from the SIM100 and verify that the switch channel indicates an "error" state.
8. Reconnect the alarm wires to the SIM100 and verify that the switch channel indicates an "off" (normal) state.
The SH-003-Kit is packaged with the original manufacturers' installation instructions. Please retain these documents and
review them for testing and maintenance procedures.
For installation support, please contact:
Copyright © 2020 Carling Technologies, Inc. All Rights Reserved
network and to the SH-003-Kit and verify that the switch channel indicates an "off"
®