8.12

Nozzle ring compression PD

For the nozzle ring (56001) to be fixed during operation, it must be clamped between the
heat shield (42400) and the turbine casing (51000).
Fig. 44: Nozzle ring compression PD
Product
A130
A135
A140
A145
Table 39: Permitted nozzle ring compression PD
42001
Bearing casing
42400
Heat shield
1. Measure dimensions A, B, and S on cleaned surfaces.
2. Calculate compression (PD).
If the calculated value (PD) lies outside the specified range, contact an ABB Turbochar-
u
ging Service Station.
© Copyright 2017 ABB. All rights reserved.
Compression PD [mm]
-0.15 ... 0.15
-0.16 ... 0.16
-0.16 ... 0.16
-0.16 ... 0.16
51000
Turbine casing
56001
Nozzle ring