2-1-4. IMAGER BLOCK SECTION

ns: not supplied
159
(Note 8)
151
(Note 5)
#197
ns
162
160
161
158
166
(Note 6)
Ref. No.
Part No.
Description
151
A-2057-087-A
SERVICE, DEVICE UNIT (1200) (Note 5)
152
4-487-617-01
IM RADIATION SHEET (2000)
* 153
Selection Parts IM WASHER (A), ADJUST (Note 2, 3)
* 154
Selection Parts IM WASHER (B), ADJUST (Note 2, 3)
* 155
Selection Parts IM WASHER (C), ADJUST (Note 2, 3)
156
A-1905-698-A
MB CHARGE UNIT (762) (Note 4)
157
1-492-255-11
SHUTTER UNIT (H129)
158
A-1932-986-A
MB N HOLDER ASSY (SERVICE 762)
159
4-542-513-01
SHEET (TOP) (783), RING HEAT (Note 8)
* 160
4-186-538-01
SPRING, LENS LOCK
ILCE-5100/5100L/5100Y_L2
1
ns
#9
152
(Note 1)
153
(Note 2, 3)
#230
154
155
(Note 2, 3)
(Note 2, 3)
Imager Unit Section
2
156
(See page 2-8)
(Note 4)
163
157
(Note 7)
164
165
#9
Ref. No.
Part No.
Description
161
X-2586-035-1
MB L LOCK PIN ASSY (762)
162
4-456-086-01
BUTTON, LENS LOCK (BLACK)
162
4-456-086-11
BUTTON, LENS LOCK (WHITE, BROWN)
* 163
4-185-963-01
MB N PLATE SP (Note 7)
164
4-284-623-01
MB N PLATE (B) 755
165
4-283-999-03
MB N PLATE A (754)
166
4-188-536-01
CAP, BODY (Note 6)
#9
3-078-890-21
SCREW, TAPPING
#197
4-185-990-01
MB SCREW, CHARGE UNIT FIXED
#230
4-287-434-01
TAPPING (1.7 (ECOLOGY))
DISASSEMBLY
1. Remove in numerical order (
) in the left figure.
1
 to
2
#9 X 3
1
Back View
#9
Screw
#9: M1.7 X 5.0 (Tapping)
#197: M1.6 X 4.5 (Tapping)
(Silver)
(Silver)
3-078-890-21
4-185-990-01
1.6
1.7
4.5
5.0
Note
Note 1: Refer to "Assembly-3: Screw tightening sequence
when assembling the Radiation Plate (IM)" when you
assemble.
Note 2: The IM adjust washers (A, B, C) differ in thickness.
Make sure to return the removed IM adjust washers to
original places.
When replacing IM adjust washers, refer to "2-2. SE-
LECTION PARTS" on page 2-10.
If the original state cannot be restored due to loss of the
IM adjust washer, for example, replace the Device Unit
(Service).
Note 3: Refer to "Assembly-4: IM Adjust Washer (A, B, C) put-
ting position" when you assemble.
Note 4: Refer to "Assembly-5: Screw tightening sequence when
assembling the MB Charge Unit" when you assemble.
Note 5: Precautions for Replacement of the Device Unit
(SERVICE)
As Mecha Device may be damaged by static electricity
from its structure, handle it carefully like for the MOS
IC.
In addition, ensure that the receiver is not covered with
dusts nor exposed to strong light.
Note 6: The Device Unit (SERVICE) includes a protective
BODY CAP.
This part is supplied only with the Device Unit (SER-
VICE).
Note 7: Refer to "Assembly-6: Apply grease on the MB N Plate
SP" when you assemble.
Note 8: Do not reuse the these sheets because its adhesive
force decreases when it is removed once.
2-7
#230 X 3
2
Back View
#230
#230: M1.7 X 4.0 (Tapping)
(Black)
4-287-434-01
1.7
4.0
Note 1:  組立時は"Assembly-3: Screw tightening sequence when
assembling the Radiation Plate (IM)"を参照してください。
Note 2:  IM調整ワッシャ (A, B, C) は, それぞれ厚さが異なります。
 
取り外したIM調整ワッシャは,必ず元の位置に戻してく
ださい。
また, IM調整ワッシャを交換する際は, 2-10ページの"2-2.
 
SELECTION PARTS"を参照してください。
 
IM adjust washerを紛失するなどして元の状態に戻せなく
 
なった場合は, Device Unit (Service) を交換してください。
Note 3:  組立時は"Assembly-4: IM Adjust Washer (A, B, C) put-
ting position"を参照してください。
Note 4:  組立時は"Assembly-5: Screw tightening sequence when
assembling the MB Charge Unit"を参照してください。
Note 5:  Device Unit (SERVICE) 交換時の注意
Mecha Device は構造上,静電気により破壊される恐れが
 
あるため,MOS ICと同様に注意して取り扱ってく ださい。
 
また,受光部にはゴミの付着,および強い光がはいるこ
とのないように注意してください。
Note 6:  Device Unit (SERVICE) には保護用のボディキャップが
含まれます。
この部品はDevice Unit (SERVICE) のみに付属されます。
 
Note 7:  組立時は"Assembly-6: Apply grease on the MB N Plate
SP"を参照してください。
Note 8:  これらのシートは一度剥がすと粘着力が弱くなるため,
再利用はしないでください。

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ilce-5100lIlce-5100y

Table of Contents