APCO CSV-1600 SURGE CHECK VALVE D12022 Instruction January 2013 DeZURIK, Inc. Sartell, Minnesota USA | Phone: 320-259-2000 | www.dezurik.com | info@dezurik.com...
Page 2
Safety label(s) on the product indicate hazards that can cause injury or death. If a safety label becomes difficult to see or read, or if a label has been removed, please contact DeZURIK for replacement label(s). Personnel involved in the installation or maintenance of valves should be constantly alert to potential emission of pipeline material and take appropriate safety precautions.
Page 4
APCO CSV-1600 Surge Check Valves Description APCO CSV-1600 Surge Check Valve is designed for installation to the inlet of the existing Air/Vacuum Valve on the line. It consists of a body, seat, flow-disc and compression spring. The surge check unit will operate on the inter-phase between the kinetic energy and relative velocity flows of air and water.
Page 5
DeZURIK APCO CSV-1600 Surge Check Valves Maintenance The APCO Surge Check Valve is automatic in operation and requires very little maintenance. It should always be installed in a vertical position. A semi-annual visual inspection for leakage is recommended. A malfunction of the Surge Check Valve can be identified by a substantial amount of spillage through the exhaust port during pump start-up.
Page 6
DeZURIK APCO CSV-1600 Surge Check Valves Operation The Surge Check Unit operates on the interphase between the kinetic energy in the relative velocity flows of air and water. The Surge Check is a normally open valve, spring loaded, so that air passes through unrestricted.
Page 7
If you use metric fasteners with ASME Class 150/300 bolt holes and flange bolt patterns, you do so at your sole risk and any liability associated with such use shall not be the responsibility of DeZURIK, Inc. In addition to the foregoing, DeZURIK’s Manufacturer’s Conditions apply.