Quick Links

Natural to Regulated LP/Propane (BG11K48)
This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in
manuals, be alert to the potential for personal injury or death.
WARNING
In the U.S., this conversion kit is to be installed
by a licensed professional service technician (or
equivalent) or other qualified agency in accordance
with the manufacturer's instructions and all codes and
requirements of the authority having jurisdiction. If the
information in these instructions is not followed exactly, a
fire, an explosion, or production of carbon monoxide may
result, causing property damage, personal injury or loss
of life. The qualified agency is responsible for the proper
installation of the kit. The installation is not proper and
complete until the operation of the converted furnace
is checked as specified in the furnace manufacturer's
instructions supplied with the kit.

Shipping and Packing List

Package 1 of 1 contains the following:
2 - LP/Propane regulator springs (77W89)
12 -Main burner orifices (0.034)
1 - Gas converter sticker
1 - Nameplate conversion sticker
1 - Low gas inlet pressure switch
1 - Gas valve inlet brass fitting
1 - Wire harness
Manufactured By
Allied Air Enterprises LLC
A Lennox International, Inc. Company
215 Metropolitan Drive
West Columbia, SC 29170
507371-02
INSTALLATION INSTRUCTIONS
Gas Changeover Kit
For BG802, BG952, BG962 Units
This manual must be left with the homeowner for future reference.
Save these instructions for future reference

Application

Use natural to LP gas conversion kit 11K48 to
convert BG802, BG952, and BG962 gas furnaces
from natural gas to regulated LP/Propane.

Installation

As with any mechanical equipment, personal injury can
result from contact with sharp sheet metal edges. Be
careful when you handle this equipment.
1.
Set the thermostat to the lowest setting. Shut off the
gas supply to the furnace, then turn off the electrical
power at the unit disconnect switch.
MANIFOLD
PRESSURE
POST
INLET
PRESSURE POST
GAS VALVE SHOWN IN OFF POSITION
Figure 1. White Rogers Gas Valve
Issue 1706
CAUTION
HIGH FIRE
LOW FIRE
ADJUSTMENT
ADJUSTMENT
SCREW
SCREW
(under cap)
(under cap)
Page 1 of 5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BG802 and is the answer not in the manual?

Questions and answers

Summary of Contents for Blueridge BG802

  • Page 1 Application WARNING Use natural to LP gas conversion kit 11K48 to convert BG802, BG952, and BG962 gas furnaces In the U.S., this conversion kit is to be installed from natural gas to regulated LP/Propane. by a licensed professional service technician (or...
  • Page 2 DO NOT use pipe dope or any pipe sealant on gas orifice threads. Figure 4. Gas Valve Conversion BG802 units with Nox inserts being converted from Remove both high fire and low fire springs from natural to LP/Propane. the gas valve. See Figure 4.
  • Page 3 IMPORTANT Carefully check all piping connection for gas leaks. DO NOT use matches, candles, open flames or other means of ignition to check for gas leaks. Use a soap solution or other preferred means. NOx Insert Re-install CAUTION Screws Some soaps used for leak detection are corrosive to Figure 5.
  • Page 4 Set the thermostat to its lowest setting. shows location of high fire adjustment screw. Turn off all electrical power to the furnace. BG802 Models Do not try to light the burners by hand. A manifold pressure post located on the gas valve provides Remove the unit access panel.
  • Page 5 Low Fire 4.8 - 6.0 5.7 - 7.0 -090 The carbon monoxide reading should not exceed 100 ppm. Table 5. BG802 -110 -135 E - Turning Off Gas to the Unit 2500 btu/cu ft Set the thermostat to its lowest setting.

This manual is also suitable for: