    Suzhou Autoda automation equipment co. LTD Contents Specifications and Parameters……………………………………………… 2 Appearance and Dimensions ……………………………………………… 4 Precautions ………………………………………………………………… 6 Functions …………………………………………………………………… 7 Main Features ……………………………………………………………… 7 Parts & Buttons and Their Functions ……………………………………… 8 Interfaces and Their Functions………………………………………………11 Software ……………………………………………………………………18 Maintenance and After-Sales Service ………………………………………23...
  • Page 3: Specificationsandparameters

    Suzhou Autoda automation equipment co. LTD SpecificationsandParameters - 2 -...
  • Page 4: Appearance And Dimensions

    Suzhou Autoda automation equipment co. LTD Appearance and Dimensions 尺寸图单位为 mm Output Port Wiring - 3 -...
  • Page 5: Precautions

    Suzhou Autoda automation equipment co. LTD Precautions Disoperation may cause damage to the force Notes gauge and even result in serious accidents. This manual describes precautions against accidents and operation methods of this product. Make sure to read this manual carefully and safe keep it after the reading.
  • Page 6: Functions

    See the following figure for correct operation method. Functions AD2016SC3 series digital force gauges are new-generation universal portable instruments for testing pull and push forces. They are characterized by compactness, lightness, portability, versatility, high precision, applicable to pull &...
  • Page 7 Suzhou Autoda automation equipment co. LTD alarm information. The two SC open-collector level outputs drive the DC 12V relay or the solenoid to act, each output being 50mA. To use output ports, connect the power adapter first. 4、 Display can be rotated 180°.
  • Page 8: Parts & Buttons And Their Functions

    Suzhou Autoda automation equipment co. LTD Parts & Buttons and Their Functions (for Embedded Products) - 7 -...
  • Page 9: Interfaces And Their Functions

    Suzhou Autoda automation equipment co. LTD Interfaces and Their Functions Test Interface: 一、 Number of Peak saved; The values Meaning of the Peak window shows: PEAK:Manual Peak Clear; PEAK ATUO:Automatic peak Clear; PEAK AVER:Average peak of the Saved peak data group;...
  • Page 10 Suzhou Autoda automation equipment co. LTD Pull(tension) sign; Alarm indicator: “—”the display value is less than the lower force limit; “○”Be tested or Fracture, end the test; “+”the display value is greater than the upper force limit; Buttons and Their Functions 二、...
  • Page 11 Suzhou Autoda automation equipment co. LTD Peak Peak value Move the blinking number leftward value saved by one unit saved Peak Peak Move the blinking number clearing clearing rightward by one unit Test Description 三、 1、power on and off:开关机操作: In shutdown mode, press to power on, in test mode, press Power off;...
  • Page 12 Suzhou Autoda automation equipment co. LTD 5、Test value output:输出测试值操作: In test mode, press current test data will output from the communication port one time (After the Computer Software online, the program will automatically disable the date output); 6、Peak clearing:峰值清除操作: In test mode, press will Clear peak value holding, and start a new Peak value hold (in alarm mode of “[F-6:j-out]=cut”,When the external input...
  • Page 13 Suzhou Autoda automation equipment co. LTD peak value (MIN) and average peak (AVER), press the ,can switch display three types of data back and forth. Peak value inquiry: entering the query interface, the down window Show one data of the peak value saved, and the corresponding No. ~...
  • Page 14 Suzhou Autoda automation equipment co. LTD the upper limit alarm value. 05 : Hi 6445.3gf ←the saved peak value of No.5, “Hi” indicate exceeds the upper limit alarm value. 06 : Hi 6476.6gf ←the saved peak value of No.6, “Hi” indicate exceeds the upper limit alarm value.
  • Page 15 Suzhou Autoda automation equipment co. LTD Menu Menu Selectable Parameter Meaning Reset Default mnemonics parameters code code Display inner code Setting zero tracking close/1d/2d/3d range Set the AD sampling speed 6~200Hz 50Hz rate Weight Calibration Do not reset Setting the 9.7000~...
  • Page 16 Suzhou Autoda automation equipment co. LTD hold time clear Set the baud rate of F-11 4800~57600 the communication 38400bps port Set the port output mode Key(Key output) Stabl(Auto output key/stabl/chang key: press Key to F-12 print steady) /conti output Chang(Change the...
  • Page 17 Suzhou Autoda automation equipment co. LTD “|Upper limit alarm value|” ,the buzzer acts while the display shows flashing alarm information “Hi、Lo”, and Lower limit output、 Upper limit output transistor is turned on(when transistors working, must plug in an external 12V power adapter);...
  • Page 18 Suzhou Autoda automation equipment co. LTD 3、Weight Calibration:[F-3:cal]( Note: The results of this action item will directly determine the accuracy of the measurement, the user please exercise caution!) Optional parameters:cal=2,cal=3 (Select calibration points, only one can be choose from two calibration methods, and the last calibration...
  • Page 19 Suzhou Autoda automation equipment co. LTD still should remain as close as possible with the default value, otherwise it will lead to a deviation measurements); Step 6:press“OK” calibrate the weight displayed by the second calibration point(If once more display the "No" error message, it means that the actual load weights may be wrong, cannot be calibrated, check the load and then press the "OK"...
  • Page 20: Software

    Suzhou Autoda automation equipment co. LTD Software While connected to a serial port of a PC over the dedicated USB line, the force gauge can make use of the dedicated software to realize unlimited storage, transmission, and reproduction of test curve data.
  • Page 21 Suzhou Autoda automation equipment co. LTD - 20 -...
  • Page 22 Suzhou Autoda automation equipment co. LTD ……1. Toolbar: shows various buttons of the software in different modes. Users can click them to perform corresponding operation. … … 2. Baud rate: it should be set consistent with the baud rate of the force gauge so that the force gauge can communicate with the PC.
  • Page 23 Suzhou Autoda automation equipment co. LTD gauge to a PC. To avoid damage to the communication port, make sure the force gauge is powered off. Select the number of a communication port for the force gauge and the PC. Select the baud rate that is consistent with that of the force gauge.
  • Page 24 Suzhou Autoda automation equipment co. LTD The system starts curve capture and countdown after capture is triggered. When the timer expires, capture is automatically completed. Curve files will be saved and statistical reports will be updated. During capture, if users click "Re-capture", the captured data will be cleared;...
  • Page 25: Maintenance And After-Sales Service

    Suzhou Autoda automation equipment co. LTD This operation will delete the selected file. Meanwhile, corresponding statistical reports will be updated. 10、Printing a curve Open a project. Click "Test Curve" in the "Switch Bar". Double-click a desired curve file in the "Curve File Bar".
  • Page 26: Battery Use And Maintenance

    Suzhou Autoda automation equipment co. LTD 7、 The warranty clauses of this product only apply to products that are sold within China. If your product has exceeded the product replacement period even the warranty period, contact the local shop or the manufacturer for maintenance service.