handtmann 12507 Operating Manual

Vacuum valve (closed type)

Advertisement

Operating manual
Vacuum valve (closed type)
12507
1
General ............................................................................................................................................................. 1
2
Safety Information ............................................................................................................................................ 2
3
Delivery, Completeness, Storage ...................................................................................................................... 2
4
Installation, Operation, Maintenance ............................................................................................................... 3
5
Additional Equipment ....................................................................................................................................... 8
1 General
1.1
Manufacturer
1.2
Proper application
1.3
Misuse
Misuse is
1.4
Duties of operator
1 / 9
Albert Handtmann Armaturenfabrik GmbH & Co. KG
Arthur-Handtmann-Str. 11; D-88400 Biberach
Tel.: +49(0) 73 51/3 42-0; Fax: +49(0) 73 51/3 42-44 80
E-Mail:
sales.fittings@handtmann.de
Vacuum valves are used in the food, beverage, pharmaceutical and chemical industries.
They are suitable for the protection of tanks and other closed systems against negative
pressure.
During installation, operation and maintenance please pay attention to the generally
accepted safety regulations as well as to the operating instructions.
Misuse is:
Application in different operating conditions as intended for the specific type.
Installation, operation and maintenance by unqualified staff.
Any unauthorized modification of the valve or a valve component.
On-observance of the operating instructions.
Any misuse will automatically lead to a loss of right to claim under guarantee as well as
any liability.
The operator has to make sure that:
The valve/component is operated properly and only in functional condition.
The legal requirements are kept during operation and maintenance.
Only sufficiently qualified and authorized staff maintain the valve/component.
The staff responsible for operation and maintenance know and obey the
operating instructions and in particular the safety advice.
The safety and warning signs remain on the valve/component and are
always legible.
Albert Handtmann Armaturenfabrik GmbH & Co. KG
BA_012507.05_EN
2017-06-14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 12507 and is the answer not in the manual?

Questions and answers

Summary of Contents for handtmann 12507

  • Page 1 Delivery, Completeness, Storage ........................2 Installation, Operation, Maintenance ....................... 3 Additional Equipment ............................8 1 General Manufacturer Albert Handtmann Armaturenfabrik GmbH & Co. KG Arthur-Handtmann-Str. 11; D-88400 Biberach Tel.: +49(0) 73 51/3 42-0; Fax: +49(0) 73 51/3 42-44 80 E-Mail: sales.fittings@handtmann.de Proper application Vacuum valves are used in the food, beverage, pharmaceutical and chemical industries.
  • Page 2: Safety Information

    Always check the material for transport damages. Possible damages have to be informed immediately. • Store the material in a dry place and if possible in its original packaging. BA_012507.05_EN 2017-06-14 Albert Handtmann Armaturenfabrik GmbH & Co. KG 2 / 9...
  • Page 3: Operation

    Protect vacuum valves from any force influence from outside. Any damage may affect the function. • Admissible temperature: 40°C Option: for higher temperatures use stainless steel valve cones. BA_012507.05_EN 3 / 9 Albert Handtmann Armaturenfabrik GmbH & Co. KG 2017-06-14...
  • Page 4 Fig. 1: DN 50 – DN 65 Fig. 2: DN 80 – DN 100 1 Valve cone 2 O-ring 3 O-ring 4 Gasket For all nominal diameters valid: The CIP-device is only optional available. BA_012507.05_EN 2017-06-14 Albert Handtmann Armaturenfabrik GmbH & Co. KG 4 / 9...
  • Page 5: Maintenance

    Any maintenance work may be carried out only in a depressurized system. In case of spare parts orders please inform us the order No. Gasket material EPDM Seals Fig. 3: Type 12507 DN 50 - 65 BA_012507.05_EN 5 / 9 Albert Handtmann Armaturenfabrik GmbH & Co. KG...
  • Page 6 Vacuum valve (closed type) 12507 Fig. 4: Type 12507 DN 80 - 100 Valve cone O-ring O-ring Gasket Spare parts 12507 012507.00050LE 012507.00065LE 012507.00080LE 012507.00100LE LE - EPDM BA_012507.05_EN 2017-06-14 Albert Handtmann Armaturenfabrik GmbH & Co. KG 6 / 9...
  • Page 7 / xxxxx code xxxxx xx / xxxxx Allocation Manufacturer Vacuum valve Valve type Nominal width / DN [mm] Set negative pressure p [mbar] Year of manufacture with manufacturing № BA_012507.05_EN 7 / 9 Albert Handtmann Armaturenfabrik GmbH & Co. KG 2017-06-14...
  • Page 8: Additional Equipment

    Casing material Stainless steel Temperature range - 25° C ... + 85° C Enclosure rating IP 68 Indicator Multi-hole – LED Fig. 5: Dimensions and connection scheme PNP BA_012507.05_EN 2017-06-14 Albert Handtmann Armaturenfabrik GmbH & Co. KG 8 / 9...
  • Page 9 № Volt Watt Volt Watt 50-100 11 125E23 11.5 105373 Heating inset Ø 6,5 x 40 Temperature control unit Fig. 6: E23, DN 50 – DN 100 BA_012507.05_EN 9 / 9 Albert Handtmann Armaturenfabrik GmbH & Co. KG 2017-06-14...