REMOTE START with KEYLESS ENTRY SYSTEM
FOR PROFESSIONAL INSTALLATION ONLY!
If you are not proficient in the installation of this product or would like a full version
of the installation manual, please visit our web site @www.magnadyne.com
Fortin or iDatalink
Bypass Module
Receiver/Control
Center(RCC)
Pink: (+) Ignition 1 Input/Output
Red: +12V Input
30A
Violet: Starter Output
Pink /White: Ignition 2 Output
Orange: Accessory Output
Red: +12V Input
30A
Red: +12V Battery Power
15A
Brown: (-) Horn Output
Black: System Main Ground
White: Parking Light Relay Output
White: Parking Light Relay Power Input
10A
Blue: - Negative Door Unlock Output
Green: - Negative Door Lock Output
16
15 14 13
12
16 Pin Accessory Harness Wiring:
8
7
6
5
4 3 2
Pin
Color
Function
1
Green/White
(-) Factory Alarm Re-Arm Output
2
Gray
(-) Hood Pin Safety Input
3
Black/White
(-) Parking Brake Input
4
Open
None
5
Brown
(+) Vehicle Brake Safety Input
6
White/Blue
External Activation Input
7
Yellow
(+) Ignition Output (to alarm)
8
Lt. Violet/White
Tach Input (AC)
16 PIN
(see chart)
11
10
9
1
Pin
Color
Function
9
Orange
(-) GND When Armed/Lock
10
Red/White
(-) Channel 3 Output (Trunk)
11
Lt. Purple/Yellow
(-) Starter Output
12
Lt. Green/Black
(-) Factory Alarm Disarm Output
13
Blue/White
(-) 2nd Status/Defrost Output
14
Dk. Blue
(-) Status Output
15
Orange/White
(-) Accessory Output
16
Pink
(-) Ignition Output

Mounting the Receiver/Control Center (RCC):

1. Choose a location on the upper or sides of the vehicle windshield.
A higher location is best.
2. Remove the backing liner from the mounting tape on the backside of the
RCC and stick it to the windshield glass.
3. Route the RCC cable to the location of the control module.

Programming System Features:

All SILENCER remote start systems have a menu of features that can
be programmed to suit the installation requirements of any vehicle.
These features can be set by using the RCC button Feature Programming
procedure or by Windows PC programming and the SILENCER web app.

Feature Programming by RCC Button

1. Open the drivers door.
2. Turn the ignition key ON then OFF.
3. Within 5 seconds, press and hold the RCC button to select the menu.
- A single chirp and LED flash indicates Menu #1.
- Hold the button longer for two chirps and two LED flashes.
You are in menu #2.
4. When the desired menu is reached, release the RCC button.
5. Within 5 seconds, press and release the RCC button the number of
times corresponding to the feature you want to change then press and
hold the button once more to lock the feature. Chirps and LED flashes
will confirm the feature chosen. Release the button. Use the buttons on
the SILENCER remote to adjust the feature.
6. For features with only two options, the
= 1 Chirp setting,
while the
= 2 Chirp setting.
7. For features with more than two settings, the
button selects the
settings in ascending order. Horn chirps indicate which option is selected.
8. Turn on the igntion key to exit Feature Programming.

Menu #1 (Default in Bold)

Chirps
Item
Feature
1
2
3
4
5
6
7
ADS
1
Data Protocol
Fortin
Ignition
2
Off
On
Locking
Ignition
3
Off
On
Unlock
Panic with
4
Off
On
Ignition On
Door Lock
5
0.8 sec. 3.5 sec. 0.4 sec.
Pulse
Double Pulse
Off
On
6
Lock
(Single)
(Double
Double Pulse
Off
On
7
Unlock
(Single)
(Double)
Factory Alarm
8
Single
Double
Disarm Pulse
Remote
Factory Alarm
With
Before
9
Start
Disarm
Unlock
Unlock
Only
Panic
10
Horn Output
20 ms
30 ms
40 ms 50 ms
Only
Comfort
11
Off
CC1
CC2
Closure
Quick Reference Install Guide

Menu #2 (Default in Bold)

Chirps
Item Feature
1
2
3
4
Transmission
1
Automatic Manual
Type
Engine Checking
Wireless
Wired
2
Voltage
Off
Mode
Tach
Tach
3
Cranking Time 0.6 sec
0.8 sec 1.0 sec 1.2 sec 1.4 sec 1.6 sec 1.8 sec 2.0 sec 4.0 sec
Remote Start
4
12 min
24 min
60 min
Run Time
Anti-Grind
5
On
Off
Output
Diesel Start
Timed
Timed
Timed
6
Off
Delay
15 sec
30 sec
45 sec
ACC Output
7
During Diesel
Off
On
Wait to Start
2nd Ignition
8
Ignition 1
ACC
Behavior
Rear
Blue / White
GND
Rear
Defog
9
Wire
When
Defog
Latched
Behavior
Running
Pulse
10 min
External Trigger
10
1 Pulse
2 Pulse 3 Pulse
Pulse Count
Parking Light
11
Constant Flashing
Behavior
Timer Mode Run
12
12 min
3 min
6 min
9 min
Time
Access another feature within the same menu
1. Press and release the RCC Button the number of times to advance from
the last feature programmed to the next feature to be programmed.
2. Press the RCC button and hold it.
3. Use the SILENCER remote and follow steps 5 or 6 above to adjust
the feature.
Access another menu
8
9
1. Press and hold the RCC Button
2. After 3 seconds, the system will advance to the next menu and conform
with chirps and LED flashes.
Exiting the feature program mode
1. Set the ignition key to ON. A long confirmation chirp will be hear if a
horn or siren is connected.
2. Automatic after 30 seconds with no input from the RCC button
(long chirp).
3. The RCC button has been press too many times (long chirp).

Feature Programming by PC/App

1. A windows computer with internet support is required. The APP supports
Windows 7 (sp1) thru Windows 10 (Apple/Mac computers are not supported)
2. The programming adaptor model #ALA-21P is required
3. Follow the instructions provided with the ALA-21P accessory.
5
6
7
8
9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 432SR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Silencer 432SR

  • Page 1 Horn chirps indicate which option is selected. 2. Press the RCC button and hold it. 8. Turn on the igntion key to exit Feature Programming. 3. Use the SILENCER remote and follow steps 5 or 6 above to adjust Menu #1 (Default in Bold) the feature.
  • Page 2 - Press and release the RCC button two times to delete all of the - If programming a 4-button remote initiate the remote start sequence. programmed remote controls. 2. If the engine does not start on the first attempt, let the SILENCER Press and hold the button, then press and release the button - Press and release the RCC button three times to delete all features module cycle and attempt to start the engine again.

Table of Contents