Technical Data (PRSU/4, PRSU/5)
Electrical data
Supply Voltage U
V
Voltage Range
Frequency
Power Consumption (typ.)
4-Wire Safety Switches
Maximum Short Circuit Resistance
Maximum Signal Wires Resistance
Conductor Data
Conductor Connection
Max. Conductor Length (input circuit)
Conductor Cross-Section
Capacitance/cable length
Reference Temperature
Contact Data
Contact Allocation
Contact Type
Contact Material
Switching Voltage
Max. Switch/Relay Current
Min. Switching Current
Max. Switching Capability (per relay)
DIN EN 60947-5-1
Max. Switching Capacity
Mechanical Lifetime
Electrical Lifetime
Creeping Distance and
Clearance
Contact Security
Short Circuit Withstand
(IEC60947-5-1)
≥1kA SCPD
Weld Free Protection at I
PSCC
(Short Circuit Protection Device)
(Fuse links), size D01
acc IEC IEC60269-1; IEC60269-3-1; VDE036-T301
Restarting Readiness Time (minimum switch off
time the inputs)
Delay on De-energisation
Mechanical Data
Housing Material
Dimensions (W
H
D)
x
x
Fastening
Humidity
Torque Setting for Connection Terminals
Weight with Terminals
Storage
Environmental data
Operating Temperature
Terminal Type
Housing Type
Shock Resistance of N.O./N.C. Contacts
Certifications
Tested I.A.W.
Achieved Level/Category
DC
CCF
MTTF
D
PFH
SFF
©
All
Copyright (2021)
rights reserved. Changes, which serve technical improvements are reserved.
PRSU/4
24V
Or 24V
DC
AC
U
± 10%
V
48Hz (min) to 62Hz (max)
+24V
: 3W, 24V
: 5VA
DC
AC
<= 200 
<= 10 
2
2 x 1.5 mm
solid wire
2
2 x 1.5 mm
stranded wire-end ferrule
UL: Use 60/75°C copper wire only!
2 x 100m (Single channel)
4 x 100m (Dual channel)
2
1.5 mm
150 nF/km (maximum)
+ 25°C
3 N.O. safety, 1 N.C. aux
Relay positive guided
AgSnO
or comparable material
2
240V
, 24V
AC
DC
5A (individual), 13.8A (combined)
10mA
AC 15 230 V / 5 A
DC 13
24 V / 5 A
1200 VA (resistive load)
7
10
switching cycles
5
10
switching cycles (DC 24V/2A)
-EN 50178 at pollution grade 2, over voltage
category 3 /250V
-Basis isolation: over voltage
category 3 / 250 V
NO contact: 6.3A brief
NC contact: 4A gL/gG
NO-contacts:
6A
NC-contacts:
6A
0.5 s
< 30 ms, 24V AC: < 50ms
Polyamide PA 6.6
22.5mm x 114.5mm x 99mm
Click-fastening for DIN-Rail
95% 0-50°C
0.5 Nm (min), 0.6 Nm (max)
UL: Overtorquing may cause
enclosure breakage
Max. 180g
In dry areas
-25°C ... +55°C ( UL:...+40°C)
IP 20
IP 40
8/2g
EN ISO 13849-1
Performance Level e, Cat. 3
90% (Medium - redundant switch off channel
with monitoring)
Achieved
100 years – high
-9
5.81 * 10
1/h
99%
PRSU/5
115V
AC
U
± 10%
V
48Hz (min) to 62Hz (max)
5VA
<= 200 
<= 10 
2
2 x 1.5 mm
solid wire
2
2 x 1.5 mm
stranded wire-end ferrule
UL: Use 60/75°C copper wire only!
2 x 100m (Single channel)
4 x 100m (Dual channel)
2
1.5 mm
150 nF/km (maximum)
+ 25°C
3 N.O. safety, 1 N.C. aux
Relay positive guided
AgSnO
or comparable material
2
240V
, 24V
AC
DC
5A (individual), 13.8A (combined)
10mA
AC 15 230 V / 5 A
DC 13
24 V / 5 A
1200 VA (resistive load)
7
10
switching cycles
5
10
switching cycles (DC 24V/2A)
-EN 50178 at pollution grade 2, over voltage
category 3 /250V
-Basis isolation: over voltage
category 3 / 250 V
NO contact: 6.3A brief
NC contact: 4A gL/gG
NO-contacts:
6A
NC-contacts:
6A
0.5 s
< 30 ms
Polyamide PA 6.6
22.5mm x 114.5mm x 99mm
Click-fastening for DIN-Rail
95% 0-50°C
0.5 Nm (min), 0.6 Nm (max)
UL: Overtorquing may cause
enclosure breakage
Max. 180g
In dry areas
-25°C ... +55°C ( UL:...+40°C)
IP 20
IP 40
8/2g
EN ISO 13849-1
Performance Level e, Cat. 3
90% (Medium - redundant switch off channel with
monitoring)
Achieved
100 years – high
-9
5.81 * 10
1/h
99%
14