Before installing, operating or maintaining the device, read and
understand this manual.
DANGER
Dangerous tension.
Danger to life or serious injury.
Disconnect the system and device from the power before
starting work.
ATTENTION
A secure device function is only guaranteed with certified
components!
Hints
The products described here are designed to perform safety-related
functions as part of an overall plant or machine. A complete safety-
related system usually contains sensors, evaluation units, signaling
devices and concepts for safe shutdowns. It is the responsibility of the
manufacturer of a system or machine to ensure the correct overall
function. Tapeswitch is unable to guarantee all the features of a
complete system or machine that was not designed by Tapeswitch. The
overall concept of the controller in which the device is integrated must be
validated by the user. Tapeswitch also assumes no liability for
recommendations that are given or implied by the following description.
Due to the following description, no new warranty, warranty or liability
claims beyond the general tapeswitch delivery conditions can be derived.
Safety Regulations
The device may only be installed and commissioned by
-
knowledgeable persons who are familiar with this operating manual
and with the applicable regulations on occupational safety and
accident prevention.
Observe the VDE and local regulations, especially with regard to
-
protective measures.
- Opening the case or unauthorized modifications will invalidate any
warranty.
- Mount the device in a control cabinet with degree of protection IP 54 or
better; Dust and moisture can otherwise lead to impairments of the
functions.
- Provide sufficient protective wiring at all output contacts for capacitive
and inductive loads.
- The safety function must be triggered during commissioning.
Intended Use
If used as directed and in accordance with this manual, no residual risks
are known. Failure to do so may result in personal injury and property
damage.
The PRSU / M2SI is used for the safety-related release and interruption of
a safety circuit. It can be used to protect people and machinery in
applications with emergency stop pushbuttons, safety gates, self-test (type
4) photocells in accordance with IEC / EN 61 496-1, two-hand switches for
metalworking presses, and other working machines with dangerous
closing movements (Type III C according to EN 574) and for safety-related
safety mats, safety edges and band switches.
E-mail: sales@tapeswitch.com • Web: www.tapeswitch.com
All information in this manual corresponds to the technical state at the time of issue. We reserve
the right to make technical improvements and changes at any time.
ENGLISH
ORIGINAL
Device Properties
Your advantages
• two independent safety functions adjustable
out:
- Safety mat / strip, band switch
- photocell
- Emergency stop switch
- Safety gate
- two-hand control
- Antivalent switch
• only one device type, two safety functions at the same time
• manual or automatic start
Characteristics
• complies
- Performance Level (PL) e and Category 4 according to EN ISO
13849-1: 2008
- SIL claim limit (SIL CL) 3 according to IEC / EN 62061
- Safety Integrity Level (SIL) 3 according to IEC / EN 61508 and IEC /
EN 61511
• according to EN 50156-1 for combustion plants
• Line fault detection on the ON button
• Activation via on-button or automatic on-function
• with or without cross-circuit detection
• 2-channel design
• positively driven output contacts
• Output: 2 NO contacts per safety function
• 1 semiconductor output per safety function
• LED indicators operating voltage, safety function 1, 2 and error
• Device connections: pluggable terminal blocks with screw terminals
Safety Instructions
ATTENTION - AUTOMATIC START!
According to IEC / EN 60 204-1 point 9.2.5.4.2, no automatic start must
be made after stopping in an emergency. Therefore, in the modes with
automatic start, a higher-level control must prevent an automatic start
after an emergency stop.
Terminals
Terminal Designation
A1 +
A2
13, 14, 23, 24,
43, 44, 53, 54
38, 68
GND
S11, S21, S31, S41
S12, S22, S32, S42,
ST1, ST2, RES
1
Signalbeschreibung
DC24V
0V
Normally open for release
circuit
Semiconductor monitoring output
Reference potential for
semiconductor signal outputs
control outputs
control outputs
Phone: 631-630-0442 • Toll Free: 800-234-8273
10/2015 EN

Advertisement

loading

Summary of Contents for Tapeswitch PRSU/M2SI

  • Page 1 • according to EN 50156-1 for combustion plants function. Tapeswitch is unable to guarantee all the features of a • Line fault detection on the ON button complete system or machine that was not designed by Tapeswitch. The •...
  • Page 2 A1 + DC 24 V The PRSU/M2SI is used to enable and interrupt a safety circuit in a safe way. It can be used to protect people and machines in applications with e-stop buttons, safety gates, light curtains with selftesting (Type 4) acc. to...
  • Page 3 Practical Notes Operating Potentiometer Operation mode Poti "Start" Adjustment of operating mode With the potentiometer on the front plate the operartion mode can be Manual- or auto start for Fkt.1 and Fkt. 2. adjustet. The adjustment must be required before energizied. Adjustment during energization is not allowed.
  • Page 4 Function diagram : max. time delay for simultaneity demand diff dependent on selected safety function Safety mat, Sensing Edge, Tapeswitch, E-Stop, Safety Gatet = max. 3s diff Light curtain t = max. 1s diff Two-hand control t = max. 0,5s...
  • Page 5 Technical Data Troubleshooting Switching capacity Failure Potential cause to AC 15 NO contacts: 3 A / AC 230 V IEC/EN 60 947-5-1 LED "ON" does not light up - Power supply A1+/A2 to DC 13 not connected NO contacts: 2 A / DC 24 V IEC/EN 60 947-5-1 LED "ERR"...
  • Page 6 Application examples with safety function PRSU/M2SI Operating mode: 3 (Fkt1=AUTO ; Fkt2=MANUAL) Safety function 1: see page 7, Auto-Start Safety function 2: see page 7, Manual-Start PRSU/M2SI Operating mode: 5 (MANUAL with common button) Safety function 1: see page 7, Manual-start with common button...
  • Page 7 Application examples with safety function 1 Schiebeschutztür geschlossen Not- M10757 M10756 M10750 Fct.: E-stop (1), Fct.: Safety gate (2), Fct.: Two-hand control (3), with cross fault detection with cross fault detection with cross fault detection SIL 3, PL e, Cat. 4 SIL 3, PL e, Cat.
  • Page 8: Circuit Diagram

    1 x 0,2 ... 2,5 mm 1 x AWG 24 to 12 2 x 0,2 ... 1,5 mm 2 x AWG 24 to 16 M10250 Dimensions (dimensions in mm) Mounting / disassembly of the terminal blocks 122,6 115,3 PRSU/M2SI 110 ± 1 22,5 10/2015 EN...
  • Page 9 HFT = 1 IEC/EN 61508 SIL CL 2, SIL 2 once per year with HFT = 1 EN 61511, EN 50156-1 SIL 3 once per year Tapeswitch Corporation Phone: 631-630-0442 Toll Free: 800-234-8273 e-mail: sales@tapeswitch.com • web: http://www.tapeswitch.com 10/2015 EN...