Contents The system System set-up Operation System maintenance Cleaning Technical specification Troubleshooting guide Waste disposal Warranty Safety Please read the following instructions carefully and observe the warning instructions before using the system. Airflo (Xiaxen) Medical Co., Ltd. 1F, 3F, 4F, No.6, East Haijing Road, Haicang, Xiamen, Fujian, China Emergo Europe B.V.
The system OSKA SeriesC Air is a cushion system which is designed to be placed on any chair. It is designed for use in nursing care at home, or in a nursing facility environment. Application – for use on a chair within home or care environment with power source nearby to ensure that comfort and relief levels are maintained.
System set-up 01. Place the pump on horizontal surface or 04. Switch on the pump power (see 2). hang by means of the hooks. The power switch indicator should now illuminate, and the pump will start to inflate 02. Place the seat cushion on the chair air tubes the cushion. should be at the rear of the chair unless there are no openings at the rear of the chair.
Operation System maintenance 01. When the pressure reaches full inflation Maintenance at regular intervals (mandatory every (within approximately 5 minutes) the normal 2 years) is necessary to preserve the function of pressure indicator will illuminate and the low the OSKA SeriesC Air alternating cushion system. pressure indicator will turn off. Used filters must be exchanged within this period. 02. Turn the pressure dial (see 5) to set a • Replace membrane unit comfortable pressure level from 40kg-130kg according to the approximate weight of the • Replace air filter patient.
Cycle time: 12 min. Static Mode Alarm Reset Mode With normal / low pressure light Size: 28cm(L) x 20cm(W) x 10cm(H) Weight: 2.2 kg Cushion OSKA – SeriesC Air Cushion Size: 49cm(L) x 46cm(W) x 10cm(H) Top cover: Dark blue bi-elastic cover with PU/ Polyester coating and zip fastening Air cells: Nylon/PVC Base: Nylon/PVC with foam insert 6 Air Cells SeriesC Air Cushion User Guide...
Possible solution If your product is still not working The pump appears The mains supply is Connect the appliance Contact OSKA Service not to be on running plugged in. The switch to the nearest mains is in the on position. socket and ensure that...
Waste disposal Warranty The materials used to manufacture the OSKA Your OSKA product comes with a 1 year parts SeriesC Air cushion do not cause any danger to and labour warranty. the environment. They may be disposed of with The warranty is based on statutory regulations.
Safety In the interest of your safety please be informed that the OSKA SeriesC Air is certified in accordance to the following regulations: Testing for DIN EN 60601-1 CPR - emergency valve ISO 13485 For your safety and the safety of those around you, please adhere to all safety and warning as detailed in this manual. WARNING! You MUST be aware of the susceptibility of this air mattress to the incidence of fire. In the case of a fire the unavoidable release of air acts as a fan effect to assist the flames.
Need help?
Do you have a question about the C Air Series and is the answer not in the manual?
Questions and answers