FIELD SERVICE MODE

Initiating Diagnostics Mode:
Note: Diagnostics mode can only be entered from a unit "'OFF" state (Not currently heating).
Mode Entry:
The Field Service mode can be entered by pressing and holding "Power On/Off" key, along with "MED" and
"PROOF" keys simultaneously for 5 seconds.
PROOF
Figure 5-2. Press Power On/Off, MED & PROOF Simultaneously to Enter Diagnostics Mode.
Operations:
Once in this mode, software version will read in timer area. Revision will be displayed initially.
NOTE: If unit is in Showroom Mode, temperature display will read "Sr" upon entering Field Service Mode. Cycling
of fan, element and drawer is non-functional. Display will show Can, CEL then Sr will be displayed at 1 second per
word then repeat until Field Service Mode is canceled or times out. To use this feature, Showroom Mode must be
canceled. See Showroom Mode for details (Section 3).
To scroll through errors control has seen, use "TIMER" up or down arrow keys. Once you begin scrolling through
errors, (i.e. "Err 10", where "Err" is displayed in the temperature readout and "10" is displayed in the timer section).
You can also scroll through additional control information parameters such as total hours used.
(See Figure 5-3 &
5-4)
NOTE: Using the opposite "TIMER" up or down arrow key will reverse your previous order.
NOTE: To clear error codes logged, press and hold "TIMER" up and down arrow keys for 5 seconds, while in
Field Service Mode. See Troubleshooting Guide page 5-3, for list of error codes and meanings.
NOTE: Once you have made it through all errors and information parameters, revision of the control will again illu-
minate, starting the sequence over.
PROOF
PROOF
Mode Exit:
Pressing the "Power On/Off key will cancel field service mode.
NOTE: If no other keypresses are noted after 2 minutes, control will also exit field service mode and power down.
#814750 - Revision A - January, 2011
(See Figure
F
POWER
ON/OFF
ON TIMER
F
POWER
ON/OFF
ON TIMER
Figure 5-3. Example of Error 10 displayed.
F
POWER
ON/OFF
ON
TIMER
Figure 5-4. Example of Element ON display.
Warming Drawer WWD30-2
5-2)
HIGH
TEMP
TEMP
TEMP
TEMP
PRESETS
MED
HIGH
TEMP
TEMP
TEMP
TEMP
PRESETS
MED
HIGH
TEMP
TEMP
TEMP
TEMP
PRESETS
MED
5-4
LOW
TIMER
PROOF
(See Figure
5-2)
LOW
TIMER
PROOF
LOW
TIMER
PROOF

Advertisement

loading