Battery Analysis - Viking 58944 Owner's Manual & Safety Instructions

6/12 volt battery load and system tester
Table of Contents

Advertisement

Battery Analysis

Battery Condition
Load Test / 10 Seconds
(Display Reading)
OK
(Green Area)
Weak
(Yellow Area)
Bad
(Red Area)
Charging System
(Alt. & Reg Test)
Battery Temperature Compensation
Page 6
Meter Display
Battery capacity is good. May or may not be fully
charged. Check the charge state by testing the Specific
Gravity (SG) with a Hydrometer (not included).
If SG is less than full charge, check for possible
charging system trouble. Recharge to full level.
If the Display Meter needle is steady, the battery capacity is not
good. Battery may be defective or partly discharged. Check SG.
If over 1.225, the battery is defective.
If below 1.225, recharge battery and retest.
If there is a difference in SG between cells over 2 points
(0.025), a particular cell may be damaged.
If charging does not bring SG to full charge level, then
battery is either sulfated or has lost its active material.
If the Display Meter needle is falling, the battery is defective
or has a bad cell. For a quick check, release the load
Toggle Switch and note Display Meter reaction.
If voltage recovers to its full potential after only a few
seconds, the battery is probably defective.
If the voltage recovers slowly, the battery may only
be run down. Check SG, recharge and retest.
If the Display Meter needle reads OK, charging system is functional.
If it falls on the low red or high red areas, charging
system may be malfunctioning.
Battery Temperature
+20°F
0°F
-20°F
For technical questions, please call 1-888-866-5797.
Battery Condition
Crank Amps Loss
50A
100A
150A
Item 58944

Advertisement

Table of Contents
loading

Table of Contents