Mitsubishi Heavy Industries HMU140KXZE1 User Manual

Mitsubishi Heavy Industries HMU140KXZE1 User Manual

Hydro module unit (hmu)

Advertisement

Quick Links

USER'S MANUAL
HYDRO MODULE UNIT (HMU)
HMU140KXZE1
HMU280KXZE1
Please refer to the manual provided with WIRED REMOTE
CONTROL (RC-EX3H)
Weitere Informationen fi nden Sie in der mit der
KABEL-FERNBEDIENUNG (RC-EX3H) mitgelieferten
Bedienungsanleitung.
Veuillez-vous reporter au manuel fourni avec la
TÉLÉCOMANDE FILAIRE (RC-EX3H)
This product complies with following directives/regulations
EU
GB
MD
2006/42/EC
SMR S.I.
2008/1597
LVD
2014/35/EU
EER S.I.
2016/1101
EMC
2014/30/EU
EMC S.I.
2016/1091
RoHS
2011/65/EU
RoHS S.I.
2012/3032
Ecodesign 2009/125/EC
Ecodesign S.I. 2020/1528
CE and UKCA marking is applicable to the area of 50 Hz
power supply
Ce climatiseur est conforme aux directives suivantes.
Machines 2006/42/CE
Basse tension 2014/35/UE
CEM 2014/30/UE
Équipements sous pression 2014/68/UE
RoHS 2011/65/UE
Écoconception 2009/125/CE
La marque CE s'applique aux régions alimentées en courant
de 50 Hz.
Consulte el manual suministrado con el MANDO A
DISTANCIA ALÁMBRICO (RC-EX3H)
Consultare il manuale in dotazione con TELECOMANDO
CABLATO (RC-EX3H)
Raadpleeg de handleiding meegeleverd met de BEDRADE
AFSTANDSBEDIENING (RC-EX3H)
Diese Klimaanlage erfüllt die folgende Richtlinie.
Maschinen 2006/42/EC
Niederspannung 2014/35/EU
EMV 2014/30/EU
Druckgeräte 2014/68/EU
RoHS 2011/65/EU
Ökodesign 2009/125/EC
Die CE-Marke gilt für Bereiche mit einer Netzstromversorgung
von 50 Hz.
Questo condizionatore d'aria è conforme alla seguente direttiva.
Macchinario 2006/42/CE
Bassa tensione 2014/35/UE
EMC 2014/30/UE
Apparecchiature a pressione 2014/68/UE
RoHS 2011/65/UE
Ecodesign 2009/125/CE
Il marchio CE è applicabile alla fascia di alimentazione 50 Hz.
ORIGINAL INSTRUCTIONS
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ U
Lütfen KABLOLU UZAKTAN KUMANDA (RC-EX3H) ile
birlikte verilen kılavuza bakınız.
Consulte o manual fornecido com o CONTROLO REMOTO
COM FIOS (RC-EX3H)
Пожалуйста, обратитесь к руководству, которое
поставляется с ПРОВОДНЫМ ПУЛЬТОМ
ДИСТАНЦИОННОГО УПРАВЛЕНИЯ (RC-EX3H)
Este aire acondicionado cumple con la siguiente directiva.
Máquinas 2006/42/CE
Baja tensión 2014/35/UE
EMC 2014/30/UE
Equipos a presión 2014/68/UE
RoHS 2011/65/UE
Ecodiseño 2009/125/CE
La indicación CE sólo corresponde al área de suministro
eléctrico de 50 Hz.
Deze airconditioner voldoet aan de volgende richtlijn.
Machine 2006/42/EC
Laagspanning 2014/35/EU
EMC 2014/30/EU
Drukapparatuur 2014/68/EU
RoHS 2011/65/EU
Ecodesign 2009/125/EC
CE-markering is van toepassing op het gebied met een net-
stroom van 50 Hz.
USER'S MANUAL
ANWENDERHANDBUCH
MANUEL DE L'UTILISATEUR
MANUAL DEL PROPIETARIO
ISTRUZIONI PER L'USO
GEBRUIKERSHANDLEIDING
KULLANIM KILAVUZU
MANUAL DO UTILIZADOR
PODRĘCZNIK UŻYTKOWNIKA
Należy zapoznać się z podręcznikiem dołączonym do PRZE-
WODOWEGO ZDALNEGO STEROWANIA (RC-EX3H)
Este ar condicionado está em conformidade com as seguintes directivas.
Máquinas 2006/42/CE
Baixa tensão 2014/35/UE
EMC 2014/30/UE
Equipamentos sob pressão 2014/68/UE
RoHS 2011/65/UE
Concessão ecológica 2009/125/CE
A marca CE aplica-se à zona de fornecimento de energia a
50 Hz.
Ten klimatyzator jest zgodny z następującymi dyrektywami.
Dyrektywa maszynowa 2006/42/WE
Dyrektywa niskonapięciowa 2014/35/UE
Dyrektywa EMC 2014/30/UE
Dyrektywa o urządzeniach ciśnieniowych 2014/68/UE
Rozporządzenie RoHS 2011/65/EU
Rozporządzenie w sprawie ekoprojektu 2009/125/WE
Oznaczenie CE ma zastosowanie do systemów zasilanych
prądem o częstotliwości 50 Hz.
MCD012A001
ENGLISH
DEUTSCH
FRANÇAIS
ESPAÑOL
ITALIANO
NEDERLANDS
TÜRKÇE
PORTUGUÊS
РУССКИЙ
POLSKI
202208

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HMU140KXZE1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mitsubishi Heavy Industries HMU140KXZE1

  • Page 1 USER’S MANUAL ORIGINAL INSTRUCTIONS HYDRO MODULE UNIT (HMU) USER’S MANUAL ENGLISH HMU140KXZE1 ANWENDERHANDBUCH HMU280KXZE1 DEUTSCH MANUEL DE L’UTILISATEUR FRANÇAIS MANUAL DEL PROPIETARIO ESPAÑOL ISTRUZIONI PER L’USO ITALIANO GEBRUIKERSHANDLEIDING NEDERLANDS KULLANIM KILAVUZU TÜRKÇE MANUAL DO UTILIZADOR PORTUGUÊS РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ U РУССКИЙ...
  • Page 3: Table Of Contents

    SAFETY PRECAUTIONS Thank you very much for your purchase of hydro module unit produced by Mitsubishi Please read these marks mean danger,  Heavy Industries. Please read through this manual before using the product and use “SAFETY PRECAUTIONS” alarm, and caution. The the product appropriately according to the instructions in the manual.
  • Page 4 INSTALLATION PRECAUTIONS DANGER Do not mount where Do not make the room too Strict compliance of the flammable gas leakage cold. DANGER domestic laws must be can happen. It may be cause of Make sure to have the observed when disposing If leaked gas stagnates in the deconditioning or health installation done by your...
  • Page 5 Normally the refrigerant does Do not wash the unit with Do not clean the inside After several seasons of not leak. But if it leaks and water, nor place a vase of the indoor unit by operating, inspections contacts fire such as fan heater, with water on the unit.
  • Page 6 PRECAUTIONS FOR Do not strain the remote The quality of circulating Before repairing or RELOCATION OR REPAIRING control cord. water shall be as specified checking indoor unit, be in the DATA BOOK for hydro sure to turn off “Indoor unit A part of core wire may be cut CAUTION module unit.
  • Page 7: How To Use

    HOW TO USE< WIRED REMOTE CONTROL (RC-EX3H) > NAMES AND FUNCTIONS OF REMOTE CONTROL BUTTONS < WIRED REMOTE CONTROL (RC-EX3H) > NAMES AND FUNCTIONS OF REMOTE CONTROL BUTTONS < WIRED REMOTE CONTROL (RC-EX3H) > NAMES AND FUNCTIONS OF SECTIONS ON THE R/C (DISPLAY) * All icons are shown for the sake of explanation.
  • Page 8: How To Operate

    HOW TO OPERATE HOW TO OPERATE < WIRED REMOTE CONTROL (RC-EX3H) > < WIRED REMOTE CONTROL (RC-EX3H) > CHANGE OPERATION MODE • In order to protect both hydro module unit and outdoor unit keep the power supply on for six hours before initial ATTENTION operation.
  • Page 9: How To Perform The Timer Operation

    HOW TO PERFORM THE TIMER OPERATION < WIRED REMOTE CONTROL (RC-EX3H) > OPERATIONS ON MENU SCREENS ADMINISTRATOR SETTINGS [ADMINISTRATOR PASSWORD] Tap the Menu button on the TOP screen and select User setting  Administrator settings . Tap the Menu button on the TOP screen. Menu 16:14 (Mon) Direction...
  • Page 10: The Selection Of Timer Mode

    HOW TO PERFORM THE TIMER OPERATION < WIRED REMOTE CONTROL (RC-EX3H) > THE SELECTION OF TIMER MODE SETTING THE TIME  Clock setting ADVICE You can set and correct the current date and time. • The Clock setting must be made when the Set ON timer by clock or Set OFF timer by clock is used. Tap the Menu button on the TOP screen and select User setting ...
  • Page 11: Sleep Timer Mode

    HOW TO PERFORM THE TIMER OPERATION < WIRED REMOTE CONTROL (RC-EX3H) > SLEEP TIMER MODE ON TIMER MODE Set ON timer by hour Tap the Menu button on the TOP screen and select Energy-saving setting  When the set time elapses, the hydro module unit starts. Sleep timer A/C will stop at the set minutes later.
  • Page 12: Weekly Timer Mode

    HOW TO PERFORM THE TIMER OPERATION < WIRED REMOTE CONTROL (RC-EX3H) > Set ON timer by clock WEEKLY TIMER MODE Starts the operation of the unit at the set clock time. You can set four on timer and off timer operations for each day of the week. Tap the Menu button on the TOP screen and select Useful functions ...
  • Page 13: Confirmation Of Current Timer Setting

    HOW TO OPERATE IN SILENT MODE < WIRED REMOTE CONTROL (RC-EX3H) > SILENT MODE Select a desired temperature (at 1°C intervals) with the Weekly timer   buttons. Or tap the Auto button to select the Auto temp setting. The OU is controlled with priority on quietness. You can start/stop the silent mode control with a single tap of a button. Silent mode control Auto must be set to the switch.
  • Page 14: Inspection Display, Standby, Room Temperature And Back Up Display

    INSPECTION DISPLAY, STANDBY, ROOM TEMPERATURE AND BACK UP DISPLAY TROUBLE SHOOTING < WIRED REMOTE CONTROL (RC-EX3H) > Check the following items before requiring service. THE UNIT DOES NOT WORK AT ALL POOR COOLING WHEN THE UNIT PROTECTION STOP IS INDICATED Is the power supply switch Is there a blackout or is Is the leakage breaker...
  • Page 15: Notice

    PREPARATION OF HEATING INSTALLATION, RELOCATION, AND INSPECTION MAINTENANCE Please observe the following points in order to use the hydro module unit in a safe and comfortable manner. CASES WHEN “IN OPERATION FOR DEFROSTING” IS DISPLAYED Make sure to request your dealer for installation, and do not attempt to do by yourself. “In operation for defrosting.”...
  • Page 16: Outdoor Unit

    MAINTENANCE AND INSPECTION GUIDELINE OF MAIN PARTS OF HYDRO MODULE UNIT AND OUTDOOR UNIT This table indicates the details of regular inspection items and their intervals adjustment” or “implementation of parts replacement and repair” according (inspection interval), and the timing of parts replacement under a normal to the result of the regular inspection is indicated as the “maintenance Explanation of symbols use condition.
  • Page 17 Explanation of symbols : Conduct the cleaning and adjustment according to the inspection result : Random failure : In case of abnormality after inspection, replace or repair the corresponding part. : Wear-out failure : Conduct the periodic replacement (consumable components) outdoor [Mainly parts and built-in components]...
  • Page 18 Explanation of symbols : Conduct the cleaning and adjustment according to the inspection result : Random failure : In case of abnormality after inspection, replace or repair the corresponding part. : Wear-out failure : Conduct the periodic replacement (consumable components) Part Name Regular Inspection Preventive Maintenance*...
  • Page 19 EU DECLARATION OF CONFORMITY UK DECLARATION OF CONFORMITY MITSUBISHI HEAVY INDUSTRIES THERMAL SYSTEMS, LTD. MITSUBISHI HEAVY INDUSTRIES THERMAL SYSTEMS, LTD. 2-3, Marunouchi 3-chome, Chiyoda-ku, 2-3, Marunouchi 3-chome, Chiyoda-ku, Tokyo, 100-8332, Japan Tokyo, 100-8332, Japan declare under our sole responsibility that the apparatus referred to in this declaration declare under our sole responsibility that the apparatus referred to in this declaration conforms with the following directives.
  • Page 20 5 The Square, Stockley Park, Uxbridge, Middlesex, UB11 1ET, United Kingdom Tel : +44-333-207-4072 Fax: +44-333-207-4089 http://www.mhiae.com MHIAE SERVICES B.V. (Wholly-owned subsidiary of MITSUBISHI HEAVY INDUSTRIES AIR-CONDITIONING EUROPE, LTD.) Herikerbergweg 238, Luna ArenA, 1101 CM Amsterdam, Netherlands P.O.Box 23393 1100 DW Amsterdam, Netherlands Tel : +31-20-406-4535 http://www.mhiaeservices.com/...

This manual is also suitable for:

Hmu280kxze1

Table of Contents