w w w . h i d e w . i t i n f o @ h i d e w . i t - Air condensed air conditioner for cellars - Air conditioner for cellars with remote air condenser - Water condensed air conditioner for cellars I N S T A L L A T I O N , U S E A N D...
Page 2
CCV - CCA - CCW – Air conditioner for cellars The reproduction of this document, even partial, without HiDew written authorization, is strictly forbidden 2 - 48 Rev 03 – Installation, use and maintenance manual...
Page 3
Technical support Service, to assist you and supply the spare parts. For a quicker assistance, please contact us at the following references: HiDew S.r.l. info@hidew.it - www.hidew.it Operational Headquarter: Via dell’Artigianato, 5 – 35026 – Conselve (PD) - Italy Tel +39 049 9502511...
CCV - CCA - CCW – Air conditioner for cellars INTRODUCTION The present User Manual indicates the uses of the unit and gives instructions for transport, installation, assembling and regulation of the machine. It gives directions about maintenance, spare parts request, residual risks presence and staff education. The User Manual should be read and used in the following way: - each operator and person concerned with the use and maintenance of the unit should read it carefully and follow the instructions given;...
CCV - CCA - CCW – Air conditioner for cellars RESPONSABILITIES The unit is granted according to the contract clauses subscribed in the sales negotiation. The manufacturer is not responsible for accidents that can occur because of: - the non-following of the instructions given in this manual about the correct use, maintenance and first-starting of the machine;...
CCV - CCA - CCW – Air conditioner for cellars USES CCV, CCA and CCW units are air conditioners for cellars, thought for a use in ambients where the non-control of temperature and humidity can damage the structure and/or the products Its use is recommended within the functioning limitations indicated in this manual Place the unit where there are not explosion or fire dangers, neither in vibrating areas or in presence of electro-magnetic fields.
CCV - CCA - CCW – Air conditioner for cellars INTERVENTION AND MAINTENANCE It is useful to remember that the manual cannot substitute the suitable experience of the user; for some maintenance operations, the manual represents a reminder of the main activities for competent operators, who have attended, for instance, instructive courses promoted by the manufacturer.
CCV - CCA - CCW – Air conditioner for cellars GENERAL SAFETY RULES 1.6.1 AFETY LOTHES Operators should wear safety equipment such as gauntlet, helmet, safety glasses, safety footwear and cap for protection from the noise. 1.6.2 XTINGUISHER AND IRST Se a first aid box and a fire extinguisher near the unit.
CCV - CCA - CCW – Air conditioner for cellars PRODUCT DESCRIPTION The new CCV, CCA and CCW air conditioners are studied and developed to ensure a precise control of temperature and humidity, especially for small private cellars and other ambiences that need precise control.
CCV - CCA - CCW – Air conditioner for cellars SERIES There are three available models, according to the type of condensation: CCV 450 CCA 450 CCW 450 OPERATIONAL LIMITATIONS Proper operation is not ensured for conditions different from which indicate below.
Page 12
CCV - CCA - CCW – Air conditioner for cellars 2.4.5 F6 A FFICIENCY ECIRCULATION ILTER More efficient filters than the standard one; they increase air cleaning and holds the micro-particles of dust, which come from the external. 2.4.6 UCTION FROM THE The unit is provided with the suction placed on the back.
CCV - CCA - CCW – Air conditioner for cellars DIRECTIONS FOR DUCTS N° 6 gaskets diameter 160 mm N° 2 gaskets diameter 160 mm N° 2 connections 10 mm CCV 450 CCA 450 13 - 48 Rev 03 – Installation, use and maintenance manual...
CCV - CCA - CCW – Air conditioner for cellars N° 2 gaskets diameter 160 mm N° 2 water connections 1/2" female gas CCW 450 ELECTRICAL CIRCUITS The electrical panel is realized and wired according to the Directive EN 60 204-1. The control circuit is protected with a specific magneto-thermal switch.
CCV - CCA - CCW – Air conditioner for cellars KEYBOARD ON-OFF KEY - on the main screen it allows the turning off of the unit - on the ‘OFF’ screen it allows the turning on of the unit EXIT KEY - it allows the exit and the coming back to the main screen - if you are modifying a value, it allows to exit from the modification - on the main screen, pushing it for 4 seconds, it allows to display the software version...
CCV - CCA - CCW – Air conditioner for cellars MAIN SCREEN USE OF KEYS With the OFF key you turn off the unit Keeping pushed the EXIT key, you display the software version With the MENU key, you enter the user menu indicates the day 19:05 on the right top indicates the time 23°C indicates the temperature...
Page 17
CCV - CCA - CCW – Air conditioner for cellars On the left you find the screen 1 of the user menu, which allows to set the functioning of the unit: MANUAL or on TIME BANDS (this screen does not appear if: the unit is managed from a serial Modbus) press OK to enter in the modification phase press UP and DOWN to modify and with OK you confirm and exit from the modification phase press EXIT to exit and come back to the main screen...
Page 18
CCV - CCA - CCW – Air conditioner for cellars On the left you find the screen 6 of the user menu, which allows the setting of the language press OK to enter the modification phase press UP and DOWN to modify and with OK you confirm and exit from the modification phase press EXIT to exit and come back to the main screen press UP to come back to the previous screen press DOWN to shift to the following screen...
CCV - CCA - CCW – Air conditioner for cellars ALARMS MENU This menu is accessible only if there is an alarm on the unit and it allows to display the active alarm and, if possible, to reset it. On the left you see the screen which allows to choose whether to display the alarm or to reset it. press EXIT to exit and come back to the main screen press UP and DOWN to select what to do press OK to confirm the choice and to shift to the further screen...
CCV - CCA - CCW – Air conditioner for cellars TIME-BANDS MENU You can access this menu only if the unit is set in time-bands and it allows to program the bands which manage the on/off, the humidity and the temperature. It is fundamental to set correct date and time, go to the screen 7 of the User Menu (additional information in the previous chapters) The default values set are:...
CCV - CCA - CCW – Air conditioner for cellars 3.6.2 UIDE Selecting this guide, you have access to 5 screens which explain how to realize the time bands. USE OF KEYS Pressing UP and DOWN you scroll among the 5 screens Pressing EXIT you come back to the main screen 3.6.3 EFAULT...
Da -5 a +35 EXTERNAL CONDENSER DIMENSIONS 463 x 300 x 286 EXTERNAL CONDENSER WEIGHT CCV 450 and CCA 450 Cooling capacity is declared at the following conditions: - internal conditions: 18°C / 80% R.H and external air: 30°C CCW 450 Cooling capacity power is declared at the following conditions: - internal conditions: 18°C / 80% R.H.
CCV - CCA - CCW – Air conditioner for cellars FUNCTIONAL DIAGRAM compressor condensing fan de-hydrator filter recirculation fan moisture/liquid indicator lamination item suction external air condensing coil expulsion external air evaporating coil suction ambient air pressure transducer inlet ambient air high pressure safety switch service outlet condensation supply valve...
Page 24
CCV - CCA - CCW – Air conditioner for cellars compressor de-hydrator filter moisture/liquid indicator lamination item condensing coil evaporating coil high pressure safety switch pressure transducer service outlet evaporation temperature probe ambient air temperature probe ambient air humidity probe condensing fan recirculation fan suction external air...
CCV - CCA - CCW – Air conditioner for cellars AFTER-SALES FAILURES In the following pages you find the more frequent possible causes of block or dysfunction of the unit. The classification is made on easy-to-identify signs. When executing the operations suggested to solve the problem, be careful: an excessive self- confiance can be dangerous.
CCV - CCA - CCW – Air conditioner for cellars ORDINARY MAINTENANCE The manufacturer recommends that the periodical maintenance is done every three months. 5.2.1 LEANING UBSTITUTION OF THE ILTERS FILTERS AMBIENT AIR FILTER EXTRACTION EXTERNAL AIR FILTER (only in CCV version) AMBIENT AIR FILTER The pictures above show the unit view with the open frontal panel;...
Page 27
CCV - CCA - CCW – Air conditioner for cellars 5.2.2 AINTENANCE ABLE To ensure the performance of the unit, it is strongly suggested to make reference to the following table for maintenance done and to be done. 4° quarter 3°...
CCV - CCA - CCW – Air conditioner for cellars DISMANTLING OF THE UNIT When dismantling the unit, please take note of the following advices: - the refrigerant gas should be recovered from qualified staff and sent to the proper collection centers; - the compressors’...
CCV - CCA - CCW – Air conditioner for cellars INSTALLATION INTRODUCTION 7.1.1 NSPECTION When receiving the unit, please check it: the unit has left our factory after having been controlled; damages should be immediately protested to the forwarder and noted on the Delivery Paper before signing it. The manufacturer or his agent should be informed as soon as possible about the entity of the damage.
CCV - CCA - CCW – Air conditioner for cellars POSITIONING It is fundamental to ensure always the complete access to the unit for the ordinary/extraordinary maintenance and calibration operations. Please keep attention to the following advices when deciding the most suitable place for the installation of the unit and its connections: •...
Page 31
CCV - CCA - CCW – Air conditioner for cellars 7.2.2 CCA C ESPECT AREA OF THE XTERNAL ONDENSER The external condenser is planned for an installation from indoor to outdoor. It is fundamental to ensure complete accessibility to the external condenser and clearances for correct airflow. We recommend the installation of anti-vibrating damper feet for each fixing point, in order to avoid the transmission of noise and vibrations.
CCV - CCA - CCW – Air conditioner for cellars HYDRAULIC AND ELECTRIC CONNECTION 7.3.1 YDRAULIC ONNECTION When preparing the hydraulic connection, it is compulsory to follow the indications below and to follow the National dispositions. Do not twine the unit connections. With a key, block the connection and, with another key, fix the connecter.
Page 33
7.3.5 SUGGESTED PROTECTION INSERTED UPSTREAM Insert upstream a magneto-thermal switch or fuses, in order to protect the unit and the electric line. CCV 450 CCA 450 CCW 450 WITHOUT OPTIONS...
Page 34
CCV - CCA - CCW – Air conditioner for cellars 7.3.6 CLAMPS AND WIRING SUPPLY SUPPLY SUPPLY SUPPLY SUPPLY SUPPLY GENERIC ALARM GENERIC ALARM REMOTE ON/OFF REMOTE ON/OFF PUMP CONTACT PUMP CONTACT CLAMPS - X1 Clamps L - N - PE are for the supply; connect the neutral N, the phase on L and the ground connection on PE. CLAMPS - X3 CLAMPS 4 - 5 are for the signal of alarm on the unit;...
Page 35
CCV - CCA - CCW – Air conditioner for cellars 7.3.7 OUTDOOR UNIT WIRING 7.3.8 RS485 MODBUS CONNECTIONS [OPTIONAL] It is recommended to keep the communication cable between the board and display as far away as possible from any power cable, in order not to compromise communication between the two. Therefore, it is strictly FORBIDDEN to pass the cable with power cables.
CCV - CCA - CCW – Air conditioner for cellars Refrigerant connections (only CCA) 7.4.1 NSTRUCTIONS FOR THE EXTERNAL CONDENSER CONNECTION CCA units have an external condenser which allows to dissipate condensation heat. For all the operations on the refrigerant circuits (ducts placement, brazing of the ducts, curves and junctions, refrigerant components installation, circuit pressure, vacuum, gas charge…) rely exclusively on qualified staff, owning a valid license.
Page 37
CCV - CCA - CCW – Air conditioner for cellars 7.4.2 UPPLY LINE INSTALLATION ONDENSER ABOVE THE VAPORATOR OMPRESSOR Remote condenser (*) inclination of the supply line between 2° and 3° to avoid the Siphon h = 200 mm return of the oil to the compressor Radius=2D every 5 mts of during the stop phases highness...
Page 38
CCV - CCA - CCW – Air conditioner for cellars 7.4.1 UPPLY LINE INSTALLATION CONDENSER BELOW EVAPORATOR COMPRESSOR Compressor’s position Inclination of the supply line between 2° and 3° to avoid the return during the stop phases ERROR: here the oil can accumulate! Liquid line: no precautions.
CCV - CCA - CCW – Air conditioner for cellars FIRST STARTING First starting, calibration and configurations should be led only by qualified staff. DO NOT IMPROVISE, NON IMPROVVISARE, UNIT MALFUNCTIONING DANGER Before starting, check that all the closing panels are in their correct position and closed with their own screws (?). For the first starting follow carefully the instructions below: Check that all the hydraulic, electric and aeraulic connections are correctly installed and that all the indications on the labels and in the user manual are followed.
Page 40
CCV - CCA - CCW – Air conditioner for cellars 7.5.2 INSTALLER PARAMETERS’ MODIFICATION The installer parameters allow to modify some advanced settings of the unit. Some parameters modify in a significant way the functioning of the unit. MODIFY ONLY IF NECESSARY To access to the installer’s menu, follow the indications below: Place on the main screen by pressing EXIT if necessary Press MENU to access to the first screen of the user menu...
Page 41
CCV - CCA - CCW – Air conditioner for cellars DEHUMIDIFICATION VALUES It allows to modify the differentials which manage the dehumidification request default: differential on 3% and differential off -1% HEATING VALUES * It allows to modify the differentials which manage the heating request default: differential on -1,0°C and differential off 0,5°C HUMIDIFICATION VALUES* It allows to modify the values of the ramp that manages the requests for humidification...
Page 42
CCV - CCA - CCW – Air conditioner for cellars ALARM HISTORY Possibility to display the unit alarms’ history. In the history alarms all the alarms are memorized, with their number and day, month and year in which it occurred. DEFAULT VALUES’...
CCV - CCA - CCW – Air conditioner for cellars CCV, CCA and CCW with option air intake from behind 47 - 48 rev03 – Installation, use and maintenance manual...