York LX Series Technical Manual page 3

Split-system heat pumps
Hide thumbs Also See for LX Series:

Advertisement

Outdoor Unit
YHJD18S41S2 YHJD24S41S4 YHJD30S41S4 YHJD36S41S4 YHJD42S41S4 YHJD48S41S4 YHJD60S41S5
1,2
Required Orifice or TXV
3,4,5
Indoor Unit
AHE18B
.051/ TXV + 0
AHE24B
AHE30B
AHE36C
AHE42D
AHE48D
AHE60D
AHR18B
.051/ TXV + 0
AHR24B
AHR30B
AHR36B
AHR42C
AHR48D
AHR60D
AHV18B
.051/ TXV + 0
AHV24B
AHV30B
AHV36C
AHV42D
AHV48D
AHV60D
AV*24
.051/ TXV + 3
AV*36
AV*48
AV*60
FC/MC/PC18
.051/ TXV + 0
FC/MC/PC24
.051/ TXV + 5
FC/MC/PC30
.051/ TXV + 5
FC/MC/PC32
FC/MC/PC35
FC/MC/PC37
FC/MC/PC43
FC/MC/PC/UC48
FC/MC/PC/UC60
FC/MC62
FC64
UC18
.051/ TXV + 1
UC24
.051/ TXV + 7
UC30
.051/ TXV + 7
UC48
UC60
Some of the combinations shown in the above System Charge table require Advanced Main Air Circulating Fan indoor product. For approved coil
only matches, please see the "COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils" table.
FOOTNOTES:
1. For applications requiring a TXV use S1-1TVM*** series kit.
2. Approved orifice(s) shipped with outdoor unit.
3. Systems matched with furnaces or air handlers not equipped with blower-off delays may require blower Time Delay Kit S1-2FD06700224.
4. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
5. Refer to Cooling and Heating Performance Data tables for actual performance for specified system matches.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the outdoor unit, the smallest matched indoor unit, and 15 feet of interconnecting line tubing.
2. Verify the TXV or orifice and additional charge required for specific matched indoor unit in the system using the above table.
3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table.
4. For indoor matches requiring additional charge, the refrigerant needs to be weighed in for specific matched indoor unit and lineset length.
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + charge adder for matched indoor unit +
charge adder for line set.
Johnson Controls Unitary Products
System Charge for Various Matched Systems
.051/4F1
.054, .059/4G1
.054 / TXV + 0
.054 / TXV + 0
.063 / TXV + 0
.063 / TXV + 25 .071 / TXV + 0
.054 / TXV + 0
.063 / TXV + 0
.063 / TXV + 25 .071 / TXV + 6
.054 / TXV + 0
.054 / TXV + 0
.063 / TXV + 0
.059 / TXV + 23 .063 / TXV + 25 .071 / TXV + 6
.059 / TXV + 23 .063 / TXV + 25 .071 / TXV + 6
.059 / TXV + 0
.063 / TXV + 0
.059 / TXV + 0
.063 / TXV + 0
.059 / TXV + 23 .063 / TXV + 25 .071 / TXV + 6
.059 / TXV + 23 .063 / TXV + 25 .071 / TXV + 6
.063/4G1
.071/4H1
Additional Charge, Oz
.071 / TXV + 16
.075 / TXV + 0
.071 / TXV + 16
.075 / TXV + 0
.071 / TXV + 16
.075 / TXV + 0
.075 / TXV + 0
.075 / TXV + 0
.071 / TXV + 16
.075 / TXV + 0
.071 / TXV + 25
.075 / TXV + 2
571209-YTG-C-1012
.075/4H1
4J1
TXV + 0
TXV + 25
TXV + 0
TXV + 25
TXV + 0
TXV + 25
TXV + 0
TXV + 0
TXV + 0
TXV + 25
TXV + 11
4K1
TXV + 0
TXV + 0
TXV + 0
TXV + 0
TXV + 23
3