Contents Description Features Instructions for use Deflation Service Instructions Re-Packing Instructions Care and Maintenance Instructions Warranty Service Record...
There is only need to open the container and drop onto the water. It inflates automatically. This Life dan buoy is composed of lifebuoy, danbuoy, weight pouch, sea anchor, life light, reflective tape and lifting loop.
Instructions for use: Open the container, and the life Victim swim to inflated life dan Circle the red webbing around torso dan buoy drop onto the water. It buoy. (under armpit), then snap the inflates automatically. carabiner on red webbing. Hold life dan buoy, waiting for Pull victim to boat by webbing rescue.
Deflation 1. Turn the dust cap upside down and insert into the oral tube. 2. Hold the dust cap in place with your finger and gently squeeze all air out of the life dan buoy. 3. Replace the dust cap. If you fail to replace, dust cap this Life dan buoy will not work.
Page 6
Do not detach the inflator from the life dan buoy. Before commencing, the re-arming procedure ensure you have the correct re-arming kit with the correct size of CO2 cylinder and that the life dan buoy is dry. Keep away from fluids. Ensure the automatic cartridge in the re-arming kit is within its Replace By Date Step 1...
Page 7
Step 3 If the inflator has been manually activated, push the lever back into its slot and clip the new manual indicator in place. Step 4 Ensure the black CO2 cylinder seal is fitted correctly.
Page 8
Step 5 Ensure the CO2 cylinder cap has not been pierced and then screw it clockwise into the UML-5 inflator. Tighten up to hand tight. (There is a gross weight on the cylinder. If you have any questions about the cylinder integrity, weigh the cylinder on a small scale, such as a postage scale.
Re-Packing window lead weight bladder tube fold line 1 Cover bag Squeeze air out of the Life-Dan Buoy, place Life-Dan Buoy flat on the ground.
Page 10
fold line 4 fold line3 fold line 4 lead weight fold line 2 fold line 1 window Put the rope inside of the anchor and fold the anchor. Put the anchor and bladder into the cover bag. lead weight Ensure the lead weight face to cap of container, and window face to Ensure whole inflator is visible Close the container.
Care and Maintenance 1) Each Use: Examine the service indicator and bottom clip(if equipped) through the window panel,ensuring it is green. If the service indicator and (or) bottom clip is red, the mechanism has been fired or is incorrectly fitted. 2) Every two years: Test the life dan buoy for general leakage by orally inflating your life dan buoy until firm and let it stand overnight.
DO NOT dry-clean, iron, use a heater or tumble dry to quicken the process. Warranty: Seago Yachting warrants to the original purchaser, consumer that the products are free from defects in materials or workmanship for 5 years from the date of purchase, provided it receives normal use and care.
Service Record MODEL: DATE: SERIAL NUMBER: OWNER’S NAME: SERVICE NEXT SERVICE AUTHORISED DATE DATE FACILITY STAMP Service by professional life raft or life jacket service station at least every two years. Refer to instructions in owner’s guide.
Page 14
Deanland Business Park Golden Cross, East Sussex ENGLAND, BN27 3RP Tel: +44 (0) 1825 873567 www.seagoyachting.co.uk...
Need help?
Do you have a question about the LIFEBUOY and is the answer not in the manual?
Questions and answers