Page 3
Note This equipment is for use in a restricted access area. Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com...
Page 7
Introduction Recommended Testing To ensure ongoing functionality of AC62, it is recommended to check the following interfaces every 6 months: ● Short each input to its adjacent GND port and verify that LED illuminates. ● Use multimeter to confirm expected impedance across relay outputs.
Page 10
Installation Mounting 1/4 Use cardboard mounting template from the previous step to get a sense of the wall space AC62 will occupy. Use mounting template to drill pilot holes for the mount plate. Please Note Leave at minimum 2” clearance on the...
● Improper grounding and shielding may result in unintended product behavior. Required Network Settings An Ethernet connection with DHCP must be used to connect the AC62 to the Local Area Network (LAN). You also need to configure firewall settings to communicate with the AC62.
Page 15
Connecting a Door 1/5 The door ports’ Form C relays can be driven dry or wet. Warning AC62 is rated to power 12V locks up to 1A and 24V locks up to 500mA. Ensure power is disconnected from the None/Dry...
Page 16
● Set it to “24VDC” for 24 volt locking hardware configuration, ensure the negative of the lock goes into the COM port as shown in the diagrams below. The AC62 is rated to power 12V locks up to 1A and 24V locks up to 500mA. Fail Safe Fail Secure...
Connecting a Door 3/5 3. Connecting the Reader The AC62 is rated to power readers at 12V up to 250mA via the + (VIN) and – (GND) connection. Verkada/RS-485 readers use the top 4-port inputs while Standard Wiegand readers use the bottom 6-port inputs.
NORMALLY CLOSED (NC) NORMALLY CLOSED (NO) The REX can be configured in Verkada Command to release the lock; this is most commonly seen in electromagnetic locks. The REX unlock time can also be configured. Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com...
The AC62 expects both AUX inputs to be NORMALLY OPEN (NO). With the AC62’s AUX inputs you can hook up devices such as intercoms and panic buttons. All associated events will be logged in Command. The AUX Inputs can be programmed in Command to initiate a lockdown or unlock a door (or a set of doors).
Page 21
16 relay outputs. In other words all wet locks will be effectively dry while the FAI is triggered. Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com...
FAI is deactivated and the latching input is temporarily open. Daisy Chaining Two AC62 FAI may be daisy chained. The FAI (and latching states) from the primary AC62 will be repeated in the secondary (daisy chained) unit. Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com...
Page 23
Connect the AC62 power supply to your standard power outlet (110VAC - 240VAC). To add the AC62 to your Verkada Command account, enter the serial number printed on the AC inlet (or the order number) to the “Add Device” page: command.verkada.com/add-device...
Installation Battery backup (Optional) A 24 volt 18Ah battery can be connected to the F2 connectors located at the bottom of the AC62. You can fit one battery at the bottom-right of the AC62. We recommend and sell a 24 volt 18Ah sealed lead acid rechargeable battery.
Page 26
Appendix Support Thank you for purchasing this Verkada product. If for any reason you're experiencing issues or need assistance, please contact our 24/7 Technical Support Team immediately. Sincerely, The Verkada Team verkada.com/support Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com...