  • Page 2 ● Endurance Level/Grade: Level 1 ● Line Security Level/Grade: Level 1 ● Standby Power Level/Grade: Level 1 Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com Copyright © 2022 Verkada Inc. All rights reserved.
  • Page 3 Note This equipment is for use in a restricted access area. Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com...
  • Page 4 After connecting the AC62 to network and power, visit: verkada.com/start For detailed installation instructions, visit: verkada.com/support Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com Copyright © 2022 Verkada Inc. All rights reserved.
  • Page 5 FAI in triggered state Controller is managing doors and connected to the server Flashing Pink Identify Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com Copyright © 2022 Verkada Inc. All rights reserved.
  • Page 6 AUX 2 Ports AUX 1 Ports FAI Port Ethernet USP Signal Door Tamper Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com Copyright © 2022 Verkada Inc. All rights reserved.
  • Page 7 Introduction Recommended Testing To ensure ongoing functionality of AC62, it is recommended to check the following interfaces every 6 months: ● Short each input to its adjacent GND port and verify that LED illuminates. ● Use multimeter to confirm expected impedance across relay outputs.
  • Page 8 Lock key and flat head screwdriver Accessories Mounting Options Mounting plate and 6 screws (#12x1") Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com Copyright © 2022 Verkada Inc. All rights reserved.
  • Page 9: Installation

    Lay AC62 on a flat surface, open the door and remove the cardboard. Keep cardboard intact for next step. Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com Copyright © 2022 Verkada Inc. All rights reserved.
  • Page 10 Installation Mounting 1/4 Use cardboard mounting template from the previous step to get a sense of the wall space AC62 will occupy. Use mounting template to drill pilot holes for the mount plate. Please Note Leave at minimum 2” clearance on the...
  • Page 11 Remove the door by sliding it upwards. Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com Copyright © 2022 Verkada Inc. All rights reserved.
  • Page 12 Secure the enclosure onto the wall using the thru holes on the enclosure. Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com Copyright © 2022 Verkada Inc. All rights reserved.
  • Page 13 Reattach the door to the enclosure. Connect the grounding cable from the enclosure to the door Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com Copyright © 2022 Verkada Inc. All rights reserved.
  • Page 14: Recommended Wiring

    ● Improper grounding and shielding may result in unintended product behavior. Required Network Settings An Ethernet connection with DHCP must be used to connect the AC62 to the Local Area Network (LAN). You also need to configure firewall settings to communicate with the AC62.
  • Page 15 Connecting a Door 1/5 The door ports’ Form C relays can be driven dry or wet. Warning AC62 is rated to power 12V locks up to 1A and 24V locks up to 500mA. Ensure power is disconnected from the None/Dry...
  • Page 16 ● Set it to “24VDC” for 24 volt locking hardware configuration, ensure the negative of the lock goes into the COM port as shown in the diagrams below. The AC62 is rated to power 12V locks up to 1A and 24V locks up to 500mA. Fail Safe Fail Secure...
  • Page 17: Connecting The Reader

    Connecting a Door 3/5 3. Connecting the Reader The AC62 is rated to power readers at 12V up to 250mA via the + (VIN) and – (GND) connection. Verkada/RS-485 readers use the top 4-port inputs while Standard Wiegand readers use the bottom 6-port inputs.
  • Page 18: Connecting The Inputs

    NORMALLY CLOSED (NC) NORMALLY CLOSED (NO) The REX can be configured in Verkada Command to release the lock; this is most commonly seen in electromagnetic locks. The REX unlock time can also be configured. Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com...
  • Page 19 For safety-related applications, wire the REX directly to the mag lock. You can wire additional REX switches and sensors to the door cassette if needed. Configuration Configuration Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com Copyright © 2022 Verkada Inc. All rights reserved.
  • Page 20: Aux Inputs

    The AC62 expects both AUX inputs to be NORMALLY OPEN (NO). With the AC62’s AUX inputs you can hook up devices such as intercoms and panic buttons. All associated events will be logged in Command. The AUX Inputs can be programmed in Command to initiate a lockdown or unlock a door (or a set of doors).
  • Page 21 16 relay outputs. In other words all wet locks will be effectively dry while the FAI is triggered. Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com...
  • Page 22: Daisy Chaining

    FAI is deactivated and the latching input is temporarily open. Daisy Chaining Two AC62 FAI may be daisy chained. The FAI (and latching states) from the primary AC62 will be repeated in the secondary (daisy chained) unit. Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com...
  • Page 23 Connect the AC62 power supply to your standard power outlet (110VAC - 240VAC). To add the AC62 to your Verkada Command account, enter the serial number printed on the AC inlet (or the order number) to the “Add Device” page: command.verkada.com/add-device...
  • Page 24: Battery Backup (Optional)

    Installation Battery backup (Optional) A 24 volt 18Ah battery can be connected to the F2 connectors located at the bottom of the AC62. You can fit one battery at the bottom-right of the AC62. We recommend and sell a 24 volt 18Ah sealed lead acid rechargeable battery.
  • Page 25 Tick mark for label placement Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com Copyright © 2022 Verkada Inc. All rights reserved.
  • Page 26 Appendix Support Thank you for purchasing this Verkada product. If for any reason you're experiencing issues or need assistance, please contact our 24/7 Technical Support Team immediately. Sincerely, The Verkada Team verkada.com/support Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com...