Page 5
Flashing Blue - Controller is managing doors, but cannot reach the server Solid Blue - Controller is managing doors and connected to the server Flashing Pink - Identify Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com...
Page 8
Installation Mounting 1/4 Use cardboard piece with the mounting template, kept from the previous step, to get a sense of the space AC62 will occupy on the wall. Use mounting template to drill pilot holes for the mount plate. Use the supplied screws to install the mount plate onto the wall.
• The other end of the drain wire shouldn’t be connected to anything. Required Network Settings An Ethernet connection with DHCP must be used to connect the AC62 to the Local Area Network (LAN). You also need to configure firewall settings to communicate with the AC62.
Page 13
Ensure power is disconnected from the AC62 and locking hardware before wiring, removing or inserting cassettes, readers, locks or any other peripherals. The AC62 comes equipped with a Form C relay that can be driven dry or wet. AC41 is rated to power 12V locks up to 1A and 24V locks up to 500mA.
Page 14
• Set it to “24VDC” for 24 Volt locking hardware configuration, ensure the negative of the lock goes into the COM port as shown in the The AC62 is rated to power 12V locks up to 1A and diagrams below. 24V locks up to 500mA.
4. Connecting the Reader The AC62 is rated to power readers at 12V up to 250mA via the + (VIN) and – (GND) connection. Verkada readers use the top 4-port inputs while Standard Wiegand readers use the bottom 6-port inputs. The drain wire of the shielded cable should be secure to the nearest AC62 chassis ground.
NORMALLY CLOSED (NC). NORMALLY OPEN (NO). The REX can be configured to release the lock in Verkada command; most commonly seen in electromagnetic locks. The REX unlock time can also be configured. Verkada Inc. 405 E 4th Ave, San Mateo, CA, 94401 All specifications are subject to change without notice.
AUX inputs to be NORMALLY OPEN (NO). With the AC62’s AUX inputs you can hook up devices such as intercoms and buttons. All associated events will be logged in Command. The AUX Inputs can be programmed in Command to initiate a lockdown or unlock a door (or a set of doors).
Page 19
FAI- and FAI_P. A jumper wire must be connected across FAI+ and FAI_P. When the contact is open, this activates the FAI in the AC62 which disables 12V/24V power to all 16 relay outputs. Normally Open Input A normally open fire alarm input from an FACP should be wired across FAI+ and FAI-.
Page 20
Daisy Chaning Two AC62 FAI may be daisy chained. The FAI and latching states from the primary AC62 will be repeated in the secondary (daisy chained) unit. Verkada Inc. 405 E 4th Ave, San Mateo, CA, 94401 All specifications are subject to change without notice.
Page 21
Connect / Powering up device Connect Connect the AC62 to your network using either of the Ethernet ports located at the bottom of the controller. If you are installing multiple controllers, you can connect up to 4 additional controllers via the spare Ethernet port on each controller.
Lead Acid Rechargeable battery. Connect Connect the AC62 to your network using either of the Ethernet ports located at the bottom of the controller. If you are installing multiple controllers, you can connect up to 4 additional controllers via the spare Ethernet port on each controller.
Page 23
Appendix Support Thank you for purchasing this Verkada product. If for any reason things don’t work right, or you need assistance, please contact us immediately. verkada.com/support Sincerely, The Verkada Team Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com...