Installation Tips; Operation - NSI 2408CD Installation And Operation Manual

Cd / cr dimmer system
Table of Contents

Advertisement

2408 CD / CR DIMMER SYSTEM
Software Revision 2.0, Version C

INSTALLATION TIPS

Care should always be taken to:
1) Keep all AC wiring away from control wiring.
2) Perform a careful inspection of control circuitry for wire clippings and verification of connections.
3) We also recommend powering up and performance checks be done one unit at a time. This
can be a real time saver should problems arise thus eliminating unnecessary isolation techniques
to resolve said problem.

OPERATION

To raise lighting levels with a 400CP remote:
Press and hold the increase button of the zone desired. If the unit is in the power down state,
power will come on in 1/4 second. The 400CP will then take control of all dimmer channels
assigned to the selected zone and increase lighting levels at the programmed fade rate. Release
button .when correct lighting levels are attained.
To lower lighting levels with a 400CP remote:
Press and hold the decrease button of the zone desired. If the unit is in the power down state,
power will come on in 1!4 second. The 400CP will then take control of all dimmer channels
assigned to the selected zone and decrease lighting levels at the programmed fade rate. Release
button when correct lighting levels are attained.
To take control with a console using DMX, AMX, Microplex, or Analog control system:
Simply perform a change in the channel level from the console. The lighting channel will then
fade back to the new console level at a moderate fade rate. Once the lighting level matches the
console level, full console control will be resumed.