Toshiba TOSVERT VF-A7 Instruction Manual page 7

Control power option unit
Hide thumbs Also See for TOSVERT VF-A7:
Table of Contents

Advertisement

Turning power on
(1) Turn on the control power.
<Note> This control power option unit can be used for both 200V inverters and 400V
inverters.
(2) LED lamp by the side of the connector (CN21) of the inverter main unit and LED lamp
inside the control power option unit light and a message appears on the monitor of the
inverter and the system is ready for setting and waiting for operation.
1) LED lamp by the side of the connector (CN21) --- lights when power is supplied to the
2) LED lamp inside the option unit --- lights when power is supplied inside of the option unit.
<Note> After turning off control power supply, do not remove the connector at least for 10
minutes. This can cause electric shock.
terminal board R0 and S0 of the
inverter main unit.
Even if control power is turned off, electrical charge
remains in the capacitor of the option unit for a while.
6
E 6 5 8 1 1 3 6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tosvert vf-p7

Table of Contents