Download Print this page
Clas Ohlson SET105R Quick Start Manual
Clas Ohlson SET105R Quick Start Manual

Clas Ohlson SET105R Quick Start Manual

Advertisement

Available languages

Available languages

Quick Links

Transformer
Article no: 32-3422 • Model: SET105R
Please read the entire instruction manual be-
fore using and save it for future reference.
Description
-
Transformer for 12 V halogen bulbs.
Comes with short connection cables (15
cm) without connectors.
-
The transformer has a soft-start feature
which gradually increases the current after
it is turned on.
-
Built-in thermal sensor which cuts the
power if the transformer overheats.
-
An electronic safety circuit turns the
transformer off if the secondary coil short-
circuits, overheats or if the transformer is
used without any load. When the fault has
been rectified the transformer can be used
again.
Safety and Assembly
-
The transformer conforms to both 89/336/
EEC Directive regarding electromagnetic
compatibility and 72/23/EEC Low Voltage
Directive.
-
Permanent installation should only be
carried out by a qualified electrician.
GREAT BRITAIN For consumer contact, please visit www.clasohlson.
co.uk and click on customer service.
ENGLISH
-
For indoor use only.
-
The primary cable must be at least 0.75
mm² and the secondary cable between
0.75 mm² and 1.5 mm².
-
To prevent high frequency power supply
interference, do not place the transformer
or its cables close to other electrical
cables.
-
The transformer should be placed as
close to the halogen lights as possible.
However not closer than 30 cm because
of the heat from the lights.
-
Make sure the transformer has adequate
ventilation and the ambient temperature
does not exceed 40°C.
Specifications
Primary voltage:
Secondary voltage:
Power:
Current:
Housing temperature: 85ºC (max)
Ambient temperature: -20ºC to + 40ºC
Overheating protection: Thermal sensor
Primary cable:
Secondary cable:
230 V, 50 Hz
11.6 V~rms
35-105 W
0.46 A
H03VVH2-F 2x0.75 mm²
1-2 cables,
0.3-4.0 m long or
3 cables,
0.3-3.0 m long or
4-6 cables,
0.3-2 m long

Advertisement

loading

Summary of Contents for Clas Ohlson SET105R

  • Page 1 For indoor use only. The primary cable must be at least 0.75 mm² and the secondary cable between Article no: 32-3422 • Model: SET105R 0.75 mm² and 1.5 mm². To prevent high frequency power supply Please read the entire instruction manual be- interference, do not place the transformer fore using and save it for future reference.
  • Page 2 Transformator Primärkablen ska vara minst 0,75 mm² och sekundärkabeln mellan 0,75 mm² och 1,5 mm². Nr: 32-3422 • Modell: SET105R För att förhindra högfrekvensinkopplingar i nätet, drag inte utgångskablarna Läs igenom hela bruksanvisningen före använd- och transformatorn nära sladdar med ning och spara den sedan för framtida bruk.
  • Page 3 Transformator Primærkabelen skal være minst 0,75 mm² og sekundærkabelen mellom 0,75 mm² og 1,5 mm². Nr: 32-3422 • Modell: SET105R For å forhindre høyfrekvensinnkoblinger i nettet, dra ikke utgangskablene og Les bruksanvisningen grundig og ta vare på transformatoren nær ledninger med den til senere bruk.
  • Page 4 SUOMI Muuntaja Ensiökaapelin tulee olla vähintään 0,75 mm² ja toisiokaapelin 0,75 mm² - 1,5 mm². Nro: 32-3422 • Malli: SET105R Verkon suurtaajuuskytkentöjen välttämiseksi ulostulokaapeleita Lue käyttöohjeet ennen tuotteen käyttöönottoa ja muuntajaa ei saa vetää ja säilytä ohjeet tulevaa tarvetta varten.

This manual is also suitable for:

32-3422