Download Print this page

JVC UX-G46B Service Manual page 35

Micro component system

Advertisement

Power section
Q909
DTC114YS
Q908
DTC114YS
C908
3.3U/50
R903
3.3K(A)
BN903
R904
CON-ASSY2.0-6P
N.M
PWR
1
DETECT
IC901
C906
2
NJM78L05
MICOM 5V
47U/50
3
Out
In
INH
Gnd
4
GND
5
AC RELAY
6
DC 12V
C907
R905
4700P
33
R907
RY901
1.2K(A)
RELAY
D901
IN4001
D902
IN4001
D903
IN4001
PT902
D904
IN4001
PT-SUB(DPL-5)
L901
FILTER-AC
D905
IN4001
CN902
CON-7.92-2P
AC 230V
1
2
COMMON
F901
AC-CORD
1
1
T1.25AL 250V
AC IN
2
2
2-6
P/T PCB
BN101
CON-ASSY2.5-4P
1
AMP AC
17
2
GND
AC 230V
16
1
1
3
GND
COMMON
2
2
15
4
AMP AC
3
14
13
AC 12V
5
4
12
4
GND
5
11
3
AC 12V
10
6
2
VFD AC
9
1
VFD AC
7
8
BN102
CON-ASSY2.5-5P
P/T UNIT SINGLE VOLTAGE
* N.M : No Mount parts
Parts are safety assurance parts.
When replacing those parts make
sure to use the specified one.

Advertisement

loading

This manual is also suitable for:

Ux-g46eUx-g46enUx-g46evUx-g47e