Flexitron webdyn MTX-StarEnergy-E Hardware User's Manual

Hide thumbs Also See for webdyn MTX-StarEnergy-E:

Advertisement

Quick Links

MTX-StarEnergy-E
Hardware User Guide
www.webdyn.com

Advertisement

Table of Contents
loading

Summary of Contents for Flexitron webdyn MTX-StarEnergy-E

  • Page 1 MTX-StarEnergy-E Hardware User Guide www.webdyn.com...
  • Page 2: Table Of Contents

    6.2 LED Status Indicators ......................22 6.3 External Interfaces ........................24 6.4 Mains Power Supply Connection ..................... 25 6.5 Antenna Connection ........................ 26 6.6 SIM Card ........................... 26 contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 3 7.6 AC Mains and DC Power Input Cable Installation ..............38 7.7 Cover Cabling Space and Seal ....................39 7.8 Power on LTE Modem and Check Operation ................40 Offices & Support Contact ....................42 contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 4: General Notes

    Read it carefully before you start working with the device. The warranty will be void should damage occur due to non-compliance with these instructions for use. We cannot accept any responsibility for consequential loss. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 5: Warranty

    1.00 2021/06 First release 1.01 2021/08 Added safety instructions and AC/DC connection details 1.02 2021/10 Added packaging details 1.03 2022/06 Added Hole Plugs and modified RS232/RS485 Cable contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 6: Installation Guide

    This guide is intended to be used by qualified installers, testers and technical engineers in order to: • Install the modem properly and safely. • Understand the equipment operation. • Verify proper operation. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 7: Safety Requirements And Protection Regulations

    SAR measurement test report and declaration. • You are responsible for observing your country’s safety standards, and where applicable, the relevant wiring rules. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 8: General Precauciones

    • When the SIM card hatch is opened, the SIM card connectors lie exposed under the SIM card holder. CAUTION: Do not touch these connectors! If you do, you may release an electrical discharge that could damage the modem or the SIM card. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 9: Antenna Precautions

    SAR regulatory requirements of the countries in which they intend to operate the device and that their documentation contains the relevant SAR declaration, certification information and user guidance as appropriate. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 10: Personal Medical Devices

    MTXGTW II-S modem radiating antenna and a pacemaker, the risk of interference is limited. If the user’s application is likely to be situated in the vicinity of personnel, a suitable warning should be contained in the equipment manual to this effect. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 11: Regulatory And Type Approval Information

    Part 52: Specific conditions for Cellular Communication Mobile and portable (UE) radio and ancillary equipment; Harmonized Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 12 High temperature: +70 ± 3 Low temperature: -25 ± 3 IEC 60068-2- Test Cab: Damp heat, steady state 96h (93 ± 3% humidity) 78:2012 Temperature +55 ± 2 contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 13: Sar Requirements Specific To Portable Mobiles

    Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment Text with EEA relevance (RoHS). contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 14: Disposal Of Old Electrical And Electronic Equipment

    The recycling of materials will help to conserve natural resources. For more detailed information about the recycling of this product, please contact your local city office, household waste disposal service or the retail store where you purchased this product. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 15: General Information

    Cable Cover Sealed Screw DIN404 (into plastic bag) 199801110 Cable Cover DIN7981 Plastic Thread (into plastic bag) 140001710 Hole Plugs for void cable entries (into plastic bag) contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 16: Features

    Power consumption Power Supply Backup Internal Supercapacitor Real Time Clock Internal Supercapacitor backup Enclosure fixing Wall mounting plate and DIN mounting compliant Enclosure protection IP51 contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 17: Product Label Marking

    Label fixed on front side of LTE Modem comprises the following information: • 1. MTX logo. • 2. Product name. • 3. Part number. • 4. Power supply operating specifications. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 18: Functional Description

    Connectors for external interfaces are grouped to be accessible at a common front panel. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 19: Lte Functionality

    5.76 Mbps B1/B5/B8 WCDMA 384 kbps 384 kbps EDGE 296 kbps 236.8 kbps B3/B8 GPRS 107 kbps 85.6 kbps Following block diagram details internal connection of LTE module. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 20 Super-Capacitor requires a charger to control charging, as long as mains power input is available. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 21 Super-Capacitor charging time, on normal operation 15sec Super-Capacitor charging time, 1st time after it has been installed 4min 15sec Backup mode discharging time (depending in network connection) 20sec – 30sec contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 22: Led Status Indicators

    DATA POWER COVERAGE Power off Power on Boot failure Fast Power failure – Operation with Slow backup super-capacitor Starting router 3 blinks Sim detected and ready Slow/Fast/ON contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 23 Fast APN connection ON (4G) TCP port in listening state with TCP encapsulation disabled TCP port in listening state with TCP encapsulation enabled Ongoing data transfer Slow contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 24: External Interfaces

    • 5. RJ45 connector for RS232 / RS485 Full Duplex signals. • 6. USB type A connector only for factory configuration and testing purposes. • 7. Reset button. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 25: Mains Power Supply Connection

    (can be connected with both polarities). Accepted wires section 22 - 12 AWG ≡ 0.5mm2 – 2.5mm2. If Modem is DC powered, it cannot be simultaneously AC powered. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 26: Antenna Connection

    To insert SIM card, look at bellow picture for proper orientation. To remove SIM card, push card slightly to release socket locking mechanism and let it be ejected. SMA INTERFACE SPECIFICATIONS Impedance Type SMA Female contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 27: Reset Button

    As no use is foreseen for this interface on regular operation at customer facilities, it has to be covered with a USB Cap, in order to avoid unexpected connection of external devices. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 28: Rs232 Dce Connection

    No hardware related configuration action is needed to enable RS232 port communication. TERMINAL RS232 DCE DESCRIPTION RS232 RX Output - WAN received data is transmitted on this output Reference common signal contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 29 Input - Data received on this Input is transmitted to WAN RS232 SPECIFICATIONS Baud Rate Max. 115200 bps ESD Protection 15kV air / 15kV contact Cable length Max. 1.5m contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 30: Rs485 Connection

    Input – RS485 data received on this Input is WAN transmitted, RS485_RX+ ‘+‘ signal. Input – RS485 data received on this Input is WAN transmitted, RS485_RX- ‘-‘ signal. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 31 RS485 SPECIFICATIONS Baud Rate Max. 115200 bps Termination Internal 120R on RS485_TX+/- pair with True Fail-Safe Bias ESD Protection 15kV air / 15kV contact Cable length Max. 1.5m contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 32: Cable Adapter To Db9 Male

    6.11 Cable Adapter to DB9 Male DB9 male connector ended cable adapter is offered to connect to RJ45 connector on LTE Modem according to bellow diagram. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 33: Installation

    • Avoid direct sunlight incidence to the LTE Modem. • Keep in mind environmental specifications as bellow table. Enclosure protection IP51 Operating temperature -25ºC to +70ºC Relative humidity Maximum 98% RH at 50ºC non-condensing contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 34: Modem Wall Mounting

    Enclosure fixing Wall mounting plate and DIN mounting compliant Dimensions without plate 160mm x 100mm x 45mm Dimensions with mounting plate 175mm x 100mm x 45mm Weight 400g contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 35 | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 36 4mm diameter drill tool as both are blind holes. • Fix LTE Modem to the wall being aware to follow bellow recommendations. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 37: Sim Card Installation

    • External antenna can also be installed. Round opening on enclosure is available for cabling installation. RG174 and RG58 cable sizes can be used. Enclosure opening is a 6.5mm diameter hole. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 38: Rs232/Rs485 Cable Installation

    7.6 AC Mains and DC Power Input Cable Installation • Refer to Mains Power Supply connection chapter for more details. • Enclosure opening is a 6.5mm diameter hole. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 39: Cover Cabling Space And Seal

    • Pay attention to the 1mm diameter crossing holes. Both holes cross completely both cabling cover and main enclosure base. contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 40: Power On Lte Modem And Check Operation

    SIM undetected or incorrect PIN: verify SIM Card is properly installed; SIM Card cannot be installed with Modem LTE powered-on WAN STATUS LED 4G Network - APN connection ON Fast 3G Network - APN connection ON contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 41 No connection to APN: verify LTE Modem is properly setup DATA STATUS LED TCP port in listening state with TCP encapsulation enabled Slow Ongoing data transfer TCP port in listening state with TCP encapsulation disabled contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...
  • Page 42: Offices & Support Contact

    Av. Coronel Eduardo Galhardo 7-1ºC 1170-105 Lisbon Phone: +351.218162625 Email: comercial@lusomatrix.pt TAIWAN 5F, No. 4, Sec. 3 Yanping N. Rd. Datong Dist. Taipei City, 103027 Phone: +886.965333367 Email: contact@webdyn.com contact@webdyn.com | webdyn.com V1.03 subject to changes | Webdyn © by Flexitron Group...

Table of Contents