Download Print this page

Lab.gruppen FP+ Series FP 10000Q Specifications page 2

Fp+ series dedicated touring amplifiers
Hide thumbs Also See for FP+ Series FP 10000Q:

Advertisement

FP+ Series: Dedicated Touring Amplifiers. Voltage Peak Limiter Load vs Power Tables
Voltage Peak Limiter
VPL Setting
150 V
121 V
101 V
83 V
70 V
56 V
47 V
38 V
Voltage Peak Limiter
VPL Setting
150 V
121 V
101 V
83 V
70 V
56 V
47 V
38 V
Voltage Peak Limiter
VPL Setting
101 V
83 V
70 V
56 V
47 V
38 V
Voltage Peak Limiter
VPL Setting
101 V
83 V
70 V
56 V
47 V
38 V
i n t e r n a t i o n a L c o n t a c t • i n f o @ L a b g r u p p e n . c o m
FP 10000Q
16 !
V peak
Vrms
150
106
121
86
101
70
83
59
70
49
56
40
47
33
38
27
Output power bridged per two channels
16 !
V peak
Vrms
300
212
2485
242
172
1740
202
140
1250
166
118
140
98
112
80
94
66
76
54
FP 6000Q
Vrms
16 !
V peak
101
70
83
59
70
49
56
40
47
33
38
27
Output power bridged per two channels
V peak
Vrms
16 !
202
140
1275
166
118
140
98
112
80
94
66
76
54
L a b . g r u p p e n a b • S w e d e n
|
w w w . l a b g r u p p e n . c o m
Output power per channel (W)
Load
8 !
4 !
620
1240
2485
435
870
1740
315
625
1250
225
450
900
160
315
630
110
220
435
80
155
315
55
110
220
Load
8 !
4 !
4970
5000
3480
5000
2500
5000
905
1810
3615
630
1260
2520
435
870
1740
315
625
1250
220
440
880
Output power per channel (W)
Load
8 !
4 !
320
640
1275
215
430
860
155
305
615
100
195
390
70
140
275
45
90
180
Load
8 !
4 !
2550
3000
860
1720
3000
615
1225
2450
390
785
1570
275
550
1105
180
360
720
u S c o n t a c t • i n f o u S @ t c e L e c t r o n i c . c o m
2 !
2500
2500
2500
1805
1260
870
625
440
2 !
n.r.
n.r.
n.r.
n.r.
n.r.
n.r.
n.r.
n.r.
2 !
1500
1500
1225
785
550
360
2 !
n.r.
n.r.
n.r.
n.r.
n.r.
n.r.
Item no. VPL-FP+

Advertisement

loading