1. Foreword Thank you for choosing JI150 series fundamental form frequency inverter. The diagrams of these operating instructions are used for convenience of explanation and may be slightly different from the product due to product upgrades. Please take this manual to the end user and keep it for future maintenance use.
Total 7 frequency sources: Digital, analog voltage, multi-speed, and serial port. Run function Limit frequency, jump frequency, frequency compensation, auto-tuning, PID control Hub van Doorneweg 8 • 2171 KZ Sassenheim – NL • +31(0)252 228850 • +31(0)252 228235 • sales@euronorm.nl • euronormdrives.com...
After completing the wiring, please check it correctly and make sure that it is correct before powering it on. 8 / 24 Hub van Doorneweg 8 • 2171 KZ Sassenheim – NL • +31(0)252 228850 • +31(0)252 228235 • sales@euronorm.nl • euronormdrives.com...
7. Parameter list In JI150 series frequency inverters ,some parameters are “manufacturer reserved”, and their serial numbers are not listed in the function parameter table,which leads to the discontinuity of some parameter serial numbers in the table. For the parameters not introduced in the manual, please do not attempt to modify them to avoid causing errors.
Under keyboard control mode, the terminal can be used to stop the inverter, same as STOP key on External parking terminal 1 the keyboard. Hub van Doorneweg 8 • 2171 KZ Sassenheim – NL • +31(0)252 228850 • +31(0)252 228235 • sales@euronorm.nl • euronormdrives.com...
Current running time of arrival When the inverter starts running time is longer than the time set by F7.45, it outputs ON signal. Hub van Doorneweg 8 • 2171 KZ Sassenheim – NL • +31(0)252 228850 • +31(0)252 228235 • sales@euronorm.nl • euronormdrives.com...
Output terminal status of the first fault ● y1.29 Power-on time of the first fault ● y1.30 Running time of the first fault Hub van Doorneweg 8 • 2171 KZ Sassenheim – NL • +31(0)252 228850 • +31(0)252 228235 • sales@euronorm.nl • euronormdrives.com...
8. Fault alarm and countermeasures JI150 can provide effective protection when the equipment performance is played fully. In case of abnormal fault, the protection function will be invoked, the inverter will stop output, and the faulty relay contact of the inverter will start, and the fault code will be displayed on the display panel of the inverter.
Page 25
Reconfirm the correct motor parameters, focus on Err.51 Initial position error actual parameters is too large whether the rated current is set to too small. Hub van Doorneweg 8 • 2171 KZ Sassenheim – NL • +31(0)252 228850 • +31(0)252 228235 • sales@euronorm.nl • euronormdrives.com...