Daikin QTRON STARLITE User Manual

Security & home automation system

Advertisement

Quick Links

Security
&
Home Automation System
QTRON STARLITE
USER MANUAL
(REVISION 1.2)

Advertisement

Table of Contents
loading

Summary of Contents for Daikin QTRON STARLITE

  • Page 1 Security & Home Automation System QTRON STARLITE USER MANUAL (REVISION 1.2)
  • Page 2 QTRON Starlite User Manual Rev 1.2...
  • Page 3: Table Of Contents

    Rev 1.2 TABLE OF CONTENTS PREFACE TESTING LIMITATIONS FEATURES QTRON STARLITE SYSTEM KEYPAD OVERVIEW I ) SUMMARY OF KEYPAD OPERATION II ) ARMING MODE III ) SOUND INDICATION IV) LIGHT INDICATION V ) KEYPAD NAVIGATION KEY FUNCTION CHAPTER 1: ALARM SYSTEM OPERATION CHAPTER 2:TELEPHONY CONTROL FLOW (With Voice) 2.1 TELEPHONY CONTROL FLOW (BEEPER)
  • Page 4 QTRON Starlite User Manual Rev 1.2 3.5 TELEPHONE NUMBER CHAPTER 4: KEYPAD SETTINGS CHAPTER 5: SYSTEM CHECKING CHECK FOR SYSTEM TROUBLE 5.1 TAMPERED AND PHONE LINE LOSS ALARM INDICATION SYSTEM TESTING 5.2.1 WALK TEST 5.2.2 CMS TEST 5.2.3 SIREN TEST 5.2.4...
  • Page 5: Preface

    Hoping that you will be fully satisfied with this choice, we ensure you with our professional assistance and information on our products. This manual will explain to you on how to operate your Qtron Starlite security and home automation system. This system is made up of a control panel, keypads, IO expander module (optional), telephone voice module (optional), various sensors and detectors.
  • Page 6: Features

    QTRON Starlite User Manual Rev 1.2 FEATURES 1. 8 fully programmable zones 2. Expandable up to 8 output controls (with feedback capability) 3. Keypad lockable. 4. 1 Real time ARM/DISARM timer on Daily Basis only. 5. 2 Real time ON/OFF timer on daily basis 6.
  • Page 7: Qtron Starlite System Keypad Overview

    QTRON Starlite User Manual Rev 1.2 QTRON Starlite SYSTEM KEYPAD OVERVIEW SUMMARY OF KEYPAD OPERATION Fast Key (Press & hold for 2s) Description AUTO AUTO HOME Arming DAY Arming NIGHT NIGHT Arming FORCE FORCE Arming AUTOMATION AUTOMATION menu VIEW ALARM MEMORY menu...
  • Page 8: Arming Mode

    QTRON Starlite User Manual Rev 1.2 ARMING MODE TYPES Arming Type Information When To Use Auto home Arming To arm the system with Exit delay When user leaves the house and no one is at home. countdown in order for the user to exit the System still able to arm house.
  • Page 9: Iv) Light Indication

    Flash zone that is triggered/ open. Keypad locked **** QTRON Starlite Keypad Display’s Reference Table NOTE: : When AC power ON, LED is ON; When AC power failure, LED is OFF : When armed, LED = ON When Emergency/Fire/Panic, LED = Flash When disarmed, LED = OFF : When trouble occurs, LED is ON;...
  • Page 10: Chapter 1: Alarm System Operation

    QTRON Starlite User Manual Rev 1.2 CHAPTER 1: ALARM SYSTEM OPERATION Security System Operation Press and hold [1] for 2 second or Press [Pin] + [#] AUTO HOME ARM Press and hold [2] for 2 second DAY ARM Press and hold [3] for 2 second...
  • Page 11: Chapter 2:Telephony Control Flow (With Voice)

    QTRON Starlite User Manual Rev 1.2 CHAPTER 2:TELEPHONY CONTROL FLOW (With Voice) System Call Out: [#] Voice Menu: “Press System Voice [Master Press any 1 for Security Menu; Report and Voice PIN] + 2 for System Status; Guidance [0] to [9] 3 for Siren Control;...
  • Page 12: Telephony Control Flow (Beeper)

    QTRON Starlite User Manual Rev 1.2 2.1 TELEPHONY CONTROL FLOW (BEEPER) System Call Out: Acceptance Beeper Slow Press any Alarm/ [Master To Force Arm System Tone beeps Event PIN] + [1] + [0] + [#] [0] – [9] Tone (Continuous tone for Alarm;...
  • Page 13: System Aleart To User Through Telephone

    QTRON Starlite User Manual Rev 1.2 SYSTEM ALERT TO USER THROUGH TELEPHONE In case of any intrusion or emergency, this system will acknowledge users with an alarm report. The panel will contact the user through fixed telephone or mobile line. If the user is unable to reply the phone call, this system will call the user again.
  • Page 14: Chapter 3: User Programming

    QTRON Starlite User Manual Rev 1.2 CHAPTER 3: USER PROGRAMMING User programming can only be access when the alarm system is under disarmed or no alarm condition. To enter user programming mode, press [COM][Pin][#]. The default Master Pin is 1234. User is advice to change the Master pin once the alarm system had been handover.
  • Page 15: Add/Change User Pin

    QTRON Starlite User Manual Rev 1.2 3.1.2 ADD/CHANGE USER PIN Command Information  The keypad will sound 2 fast beeps after Press the user number (02-08) then enter the 4 digits new pin then re-enter the same pin again and press # pressing 02-08, then keypad will sound after done.
  • Page 16: Timer Setting

    QTRON Starlite User Manual Rev 1.2 3.4 TIMER SETTING 3.4.1 AUTO ARM TIMER  This allow user to set timer to auto Arm the system. Command Information  The keypad will sound 2 fast beeps after pressing Press 11 then set the auto arm timer in 24 hour format and press # after done.
  • Page 17: 4Automation(I/O) Off Timer

    QTRON Starlite User Manual Rev 1.2 3.4.4 AUTOMATION (I/O) OFF TIMER  It is to set the timer to turn OFF the outputs automatically. Command Information  The keypad will sound 2 fast beeps after pressing Press 14 then set the timer 1 to turn off the...
  • Page 18 QTRON Starlite User Manual Rev 1.2 CHAPTER 4: KEYPAD SETTINGS In order to access to the keypad setting, the system must enter user programming mode. The following are the keypad setting’s functions and how to change the setting. Functions Command...
  • Page 19 QTRON Starlite User Manual Rev 1.2 CHAPTER 5: SYSTEM CHECKING SERVICE CHECK System must be in normal or armed mode in order to view trouble. Control panel will monitor a number of possible trouble conditions. If one of these conditions occurs, the SERVICE light will turn ON and remain ON until trouble free and/or it receives clearance instruction from the users.
  • Page 20 QTRON Starlite User Manual Rev 1.2 SYSTEM TESTING Users are advised to test the system frequently. System must be tested at least once every three months. If the system is not functioning accordingly, please contact the nearest dealer for technical assistance. In order to test the alarm system, system must be on normal mode. There are5types of tests: walk test, cms test, siren test, strobe light test and battery test.
  • Page 21 Bypass Removal of one or more protection zones from the system Central Monitoring Station (CMS) Central control station to receive the alarm message from QTRON Starlite system. Chime A beep tune from the keypad to indicate sensor is activated Duress Pin...
  • Page 22 QTRON Starlite User Manual Rev 1.2 SYSTEM’S INFORMATION MASTER USER: ADDRESS: TELEPHONE NUMBER: DATE : REMARKS : Telephone Number 1 Receiver Number 1 Receiver Type User / CMS Receiver Pattern Permanent / Backup CMS Account Number 1 Telephone Number 2...
  • Page 23 QTRON Starlite User Manual Rev 1.2 Zone Settings Zone Zone Type Zone Output Description Chime Light/Interior/Instant/Delay/24 Hours Yes/No Light/Interior/Instant/Delay/24 Hours Yes/No Light/Interior/Instant/Delay/24 Hours Yes/No Light/Interior/Instant/Delay/24 Hours Yes/No Light/Interior/Instant/Delay/24 Hours Yes/No Light/Interior/Instant/Delay/24 Hours Yes/No Light/Interior/Instant/Delay/24 Hours Yes/No Light/Interior/Instant/Delay/24 Hours Yes/No Output Settings...
  • Page 24 QTRON Starlite User Manual Rev 1.2...

Table of Contents