Crystal Vision M-SAFESWITCH-2 User Manual

Ip/sdi dual channel 2 x 1 fail-safe routing switches

Advertisement

Quick Links

M-SAFESWITCH-2
and
M-SAFESWITCH-2L
IP/SDI dual channel 2 x 1 fail-safe routing
switches
Crystal Vision Ltd., Lion Technology Park, Station Road East, Whittlesford, Cambridge, CB22 4WL, England.
Tel: +44(0) 1223 497049 sales@crystalvision.tv www.crystalvision.tv

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the M-SAFESWITCH-2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Crystal Vision M-SAFESWITCH-2

  • Page 1 M-SAFESWITCH-2 M-SAFESWITCH-2L IP/SDI dual channel 2 x 1 fail-safe routing switches Crystal Vision Ltd., Lion Technology Park, Station Road East, Whittlesford, Cambridge, CB22 4WL, England. Tel: +44(0) 1223 497049 sales@crystalvision.tv www.crystalvision.tv...
  • Page 2: Table Of Contents

    Audio Status Status Delay Network Status & Statistics Flow Statistics Network In/Protect Network In pkts Safe Switch Processing A and B Sources Auto Switch Configuration Video & Network errors Audio errors Switching Modes M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 3 11 Unicast Flow Configuration 12 Basic Trouble Shooting 12.1 No input or output signals present 12.2 Errors in the IP flow’s video content 12.3 IP flows keep stopping after a few minutes 13 Specification M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 4 User interface screen shots updated to align with V2.3 MARBLE-V1 and V1.19 21/07/22 Vision 3 software releases. Added new audio switching, audio monitoring and audio mute features. Added new preset features. Updated use of flow terminology. M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 5: Introduction

    – useful for planned maintenance on the primary programme channel. Like all MARBLE-V1 video processing software apps, the M-SAFESWITCH-2 and M- SAFESWITCH-2L can be used with IP (ST 2022 or ST 2110 video), with SDI or with both IP and SDI at the same time (thereby providing gateway functionality).
  • Page 6 Flexible remote control and monitoring using frame integrated control panel, VisionPanel remote control panel, ASCII and JSON protocols, SNMP and the web browser-based VisionWeb Control • Dual slot card allowing 10 cards in Vision 3 frame M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 7: Block Diagram

    Crystal Vision Block Diagram 2 Block Diagram M-SAFESWITCH-2 N.B. M-SAFESWITCH-2L as above but with the addition of RGB legalisers on each of the outputs M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 8: Hardware Installation

    The potentiometers on the card are factory set and should not be adjusted. There are no user-selectable links. The app based MARBLE-V1 cards are intended for use only in the Crystal Vision ‘Vision’ frame range and not in older style frames such as ‘Indigo’.
  • Page 9: O Configuration

    IP address. It is, however, possible to use the same virtual interface for all input and output flows. If using SDI I/O with an analogue reference no virtual interfaces will need configuring. M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 10 Crystal Vision I/O Configuration In a fully IP environment, the following example shows how the M-SAFESWITCH-2/2L primary and protect input and output flows could be assigned to individual virtual interfaces. As previously mentioned, it is also possible to assign all flows to the same interface.
  • Page 11: Enabling Inputs & Outputs

    I/O Configuration 4.2 Enabling Inputs & Outputs By default M-SAFESWITCH-2/2L inputs and outputs are disabled. Use the Enable control within the Input and Output menus to enable them. To prevent exceeding the network interface and processing bandwidth, 3G video inputs are supported on inputs 1 and 3 only.
  • Page 12: Select I/O Protocol

    I/O Configuration 4.3 Select I/O Protocol M-SAFESWITCH-2/2L supports SDI and uncompressed video over IP protocols ST 2022 and ST 2110-20. It is possible to mix protocols between input and outputs. For example, an ST 2022 input can be output as SDI on Output 1 and ST 2110 on Output 2.
  • Page 13: Receiving An Ip Flow

    I/O Configuration 4.4 Receiving an IP Flow M-SAFESWITCH-2/2L receives ST 2022 or ST 2110-20 video over IP flows using the 10GbE network interfaces on the VR04/VR06/VR07 Vision frame rear connector. Typically Eth 1 is used for receiving and transmitting the ‘primary’ IP flows, with Eth 2 being used for the ‘protect’...
  • Page 14: Transmitting An Ip Flow

    I/O Configuration 4.5 Transmitting an IP Flow M-SAFESWITCH-2/2L transmits ST 2022 or ST 2110-20 video over IP flows using the 10GbE network interfaces on the VR04/VR06/VR07 Vision frame rear connector. Typically Eth 1 is used for receiving and transmitting the ‘primary’ IP flows, with Eth 2 being used for the ‘protect’...
  • Page 15 When transmitting ST 2110 the required payload type value should be set. The value for payload type is arbitrary and decided by the user. For example, value 100 could be used to indicate 1920x1080i 50Hz content and value 101 used to indicate 625i 50Hz content. M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 16: Status

    Red if CRC errors detected at input, otherwise off Ancillary data error LED: Red if ANC data errors detected at input, otherwise off Network error LED: Red if lost or duplicate packets are detected on primary or protect network input M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 17: Input Audio Status

    Audio silent, video black and video frozen status can be prevented from triggering until a user selectable delayed period between 1 to 120 seconds has expired. These controls are located within the ‘Defaults’ tab and are also duplicated on each of the ‘Safe Switch’ tabs. Status delay M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 18: Network Status & Statistics

    Protect %: Percentage of packets used from the ‘protected’ network input Skew: Difference in packet arrival. –ve indicates protect packets are arriving first Network In/Protect Network In pkts Lost: Number of lost packets M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 19 Crystal Vision Status Duplicate: Number of duplicate packets Min gap: Minimum gap between packets (nSec) Max gap: Maximum gap between packets (nSec) Mean gap: Mean gap between packets of a frame (nSec) M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 20: Safe Switch Processing

    Safe Switch Processing 6 Safe Switch Processing M-SAFESWITCH-2/2L features dual independent 2x1 switches. Source A to B switching can be triggered automatically based upon user configurable input fault conditions, or manually – useful for planned maintenance on the primary programme channel.
  • Page 21: Auto Switch Configuration

    The switch to Source B will occur regardless of whether or not the flow assigned to Source B contains errors. It is therefore recommended that all inputs are continuously monitored for errors, using SNMP for example. M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 22: Audio Errors

    The ‘Delay audio silent’ control allows audio to be silent for the set amount of time before triggering the switch. This is adjustable between 1 and 120 seconds and is a global setting which applies to both to switch 1 and 2. M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 23: Switching Modes

    B. If 'Delayed' restore mode is set, the switch will still automatically return to Source A after manually selecting Source B. To remain with Source B, 'Latched' mode should be selected. Switching modes M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 24: Output Routing

    Safe Switch Processing 6.4 Output Routing M-SAFESWITCH-2/2L features dual independent 2x1 switches. There are three outputs. Outputs 1 and 2 out can be configured to be either IP or SDI. Output 3 is IP only. By default outputs 1 and 3 route to the processing from Switch 1. Output 2 routes to Switch 2.
  • Page 25: Output Legalising (M-Safeswitch-2L Only)

    Constant hue mode transforms RGB to Hue Saturation Intensity colour space and reduces saturation without changing hue. M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 26: References And Output Timing

    Timing 8.1 References The M-SAFESWITCH-2/2L outputs can be locked to a PTP clock, an analogue tri-level or Black & Burst sync or the SDI input if present and selected as the flow in protocol. If the chosen reference sources are absent at power up, the outputs will freerun to an internally generated clock.
  • Page 27: Reference Configuration

    Read only text showing the MAC address of the PTP clocks Interface: Ethernet interface chosen to receive the PTP clock. The interface chosen must be configured for the same IP range and as the PTP clock M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 28: Ptp Statistics

    The output timing controls are sub-frame time based (ms and us). Status is provided for the equivalent lines and pixels delay. Output timing Output Timing Enable: Select to enable the output timing controls. Minimum possible delay applied when deselected M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 29: Frame Delay

    Read only status of the output timing in equivalent lines and pixels 8.3 Frame delay Up to ten frames of delay adjustable in one frame steps can be applied to the input and each output. Input Frame Delay Output Frame Delay M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 30: Traffic Shaping Profile

    For both SMPTE ST 2022 and ST 2110-20 protocols it is possible to ‘burst’ the packets out as fast as possible, using the ‘Burst rate limit’ control to determine the maximum bandwidth the burst traffic will limit to. Traffic Shaping Profile M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 31: Input Format, Input Loss And Test Pattern Options

    ‘On input/format loss’ function is triggered. In the example below, if the source input format is not 1920x1080i 50Hz, the output will be replaced with colour bars. Input Format and On Loss Options M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 32: Internal Test Patterns

    10.3 Audio mute Embedded audio present in SDI or ST 2022 inputs will be passed through to the outputs. Use the Audio mute controls to mute embedded audio present on the output. Audio mute M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 33: Unicast Flow Configuration

    Ethernet Interface you want to transmit to. The example below shows that rather than transmitting using a multicast address, interface 1:5 on the M-SAFESWITCH-2 is now set to transmit the flow to a downstream device with IP address 192.168.5.80.
  • Page 34 IP address, as shown in the example below, where the source address is limited to only receiving traffic from a device with IP Address 192.168.5.56. Unicast IP Address receive M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 35: Basic Trouble Shooting

    12000ns (0.012us). Larger gaps could indicate bursts in the IP packets 12.3 IP flows keep stopping after a few minutes • Check IGMP is enabled and correctly configured on the network switch M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 36: Specification

    Crystal Vision Specification 13 Specification M-SAFESWITCH-2/2L APPS RUNNING ON MARBLE-V1 MEDIA PROCESSOR MECHANICAL ‘Double slot’ Vision card 96mm x 303mm (96mm x 325mm including finger pull) Weight: 355g Power consumption: 25 Watts, plus 1 Watt for each SFP+ fitted to MARBLE-V1...
  • Page 37 These can be switched either manually (using the Switch to A and Switch to B buttons) or automatically In auto mode M-SAFESWITCH-2 will always want to be on its primary input (Source A), only switching to secondary input B if there are user-defined faults on the primary input. It is M-SAFESWITCH-2/2L User Manual R1.4...
  • Page 38 Source A once it has been clear of the monitored faults for the time set on the Restore delay slider, with the time programmable between two and 60 seconds When the Restore to A mode is set to "Latched", M-SAFESWITCH-2 will stay switched to Source B until the user manually restores it to Source A...
  • Page 39 – should the timing source at the top of the list become missing or invalid, the app will move down the list until it finds a valid timing reference source. M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 40 All ancillary data (including audio and locked Dolby E) is passed from SDI or ST 2022 input to SDI or ST 2022 output. When ST 2110 input or output is selected, all ancillary data is discarded LED INDICATION OF: Power okay M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 41 Silence group 3 channel 10 • Silence group 3 channel 11 • • Silence group 3 channel 12 Silence group 4 channel 13 • Silence group 4 channel 14 • • Silence group 4 channel 15 M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...
  • Page 42 SBB-4 smart button box connects to the frame via Ethernet and provides four programmable LCD switches (which are configured for each order). The SBB-4 uses information from VisionWeb for settings. Uses Power over Ethernet so must be used with PoE enabled switch M-SAFESWITCH-2/2L User Manual R1.4 21 July 2022...