Download Print this page
Omega Engineering HE-XT105 User Manual

Omega Engineering HE-XT105 User Manual

Advertisement

Quick Links

User' s Guide
MADE IN
Shop online at
omega.com
e-mail: info@omega.com
For latest product manuals:
omegamanual.info
HE-XT105
12 Digital DC Inputs,
12 Digital DC Outputs,
2 Analog Inputs Including
T/C & RTD (High Resolution),
2 Analog Outputs

Advertisement

loading

Summary of Contents for Omega Engineering HE-XT105

  • Page 1 User’ s Guide MADE IN Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info HE-XT105 12 Digital DC Inputs, 12 Digital DC Outputs, 2 Analog Inputs Including T/C & RTD (High Resolution), 2 Analog Outputs...
  • Page 2 FAX: +44 (0)161 777-6622 e-mail: sales@omega.co.uk It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
  • Page 3 Specifications Digital DC Inputs Digital DC Outputs Inputs per Module 12 including 4 configurable HSC inputs Outputs per Module 12 including 2 configurable PWM outputs rcing / 10 K Pull-Down Input Impedance 10 kΩ Input Current Positive Logic Negative Logic Upper Threshold 0.8 mA -1.6 mA...
  • Page 4 Panel Cut-Out and Dimensions Wiring and Jumpers Note: Max. panel thickness: 5 mm. Wire according to the type of inputs / outputs used and select the appropriate jumper option. Use Copper Conductors in Field Wiring Only, 60/75° C Wiring Specifications Location of I/O jumpers (JP) and wiring connectors •...
  • Page 5 External DIP Switch Settings (or Jumpers Settings) I/O Register Map As seen when looking at the top of the XLt unit: Refer to Registers Description Section 3 for the location of the External Jumpers. The External DIP Switches are used for termination of the RS-485 ports.
  • Page 6 Digital Filtering for Analog Inputs Safety The digital filter is updated once per conversion. It is an “IIR” running average filter When found on the product, the following symbols specify: that emulates a simple RC filter. The equivalent time constant is determined by the Filter Constant and the sum of the conversion times for the two channels.
  • Page 7 WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
  • Page 8 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers PRESSURE, STRAIN AND FORCE Transducers &...