15.
Directly connected CTs
Configure any hardwired CTs that you have connected at
step 10 in the CT Config menu. Three phase zappis will
need one CT per phase. You will need to use a harvi to
connect any other CTs you want to use (Unless you have
other zappis or eddis on each phase that you can connect
to instead).
(Press menu button > Other Settings >
Advanced > 0000 > CT Config)
At this point, refer to step 10 to see what you have
connected to CT1, CT2, CT3
NB. Leave CTINT settings set to factory default unless
advised otherwise by myenergi Technical Support.
Please read
& WiFi Module instructions for set-up, connecting your device to the
vHub
internet, enabling the built-in
Technical Support
If you experience any issues during or post set-up, please contact our technical support team by scanning the QR Code
below.
Please contact us directly for the quickest solution.
D3405 UNITED KINGDOM
16.
CTs connected using harvi
If using a harvi, once the harvi has been paired, make sure that you
have disabled the corresponding hardwired CTs on the zappi CT
Config menu (See step 15).
i.e. If the Grid CT is wired into a harvi make sure that none of the
hardwired CTs are also set to Grid.
harvi if installing in UK.
For more information on setting up harvi please refer to the full
harvi manual instructions.
and pairing to other
vHub
https://myenergi.com/manual-support/
NOTE: Do NOT wire Grid CT into
LINKED DEVICES
Readings...
TYPE:
CT1:
CT2:
CT3:
Remove Device
IMPORTANT!
One CT must be set to GRID
There must be only ONE GRID CT
If the GRID CT is connected to the harvi, make sure that
you have turned off the hardwired GRID CT
NOTE: Do NOT wire Grid CT into harvi if installing in
UK.
devices.
myenergi
HARVI
Single Phase
Grid
None
None
Rev 2.1.0 May 2022