Read this manual BEFORE using this equipment.
Failure to read and follow all safety and use information can result in death, serious personal injury, property damage, or damage to the equipment.
Keep this manual for future reference.
The antenna used for this radio must be properly installed and maintained and must provide a separation distance of at least 7.9 inches (20 cm) from all persons.
This device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
This is a safety-alert symbol. The safety-alert symbol is shown alone or used with a signal word (DANGER, WARNING, or CAUTION), a pictorial and/or a safety message to identify hazards.
When you see this symbol alone or with a signal word on your equipment or in this manual, be alert to the potential for death or serious personal injury.
This pictorial alerts you to electricity, electrocution, and shock hazards.
This symbol identifies hazards which, if not avoided, could result in death or serious injury.
This symbol identifies practices, actions, or failure to act, which could result in property damage or damage to the equipment.
Installation must be performed by qualified persons, in accordance with local codes, ANSI/NFPA 70 (NEC Article 424) and CEC Part 1 Section 62 where applicable. Prior to installation, please consult the local codes in order to understand what is acceptable. To the extent this information is not consistent with local codes, the local codes should be followed. Regardless, electrical wiring is required from a circuit breaker or other electrical circuit to the control. It is recommended that an electrician perform these installation steps. Please be aware local codes may require this product to be installed by an electrician.
The following cautions must be observed:
ALWAYS install the floor sensor included with the thermostat.
NEVER put the system into full operation until the tile or flooring installer verifies all cement materials are fully cured (typically two to four weeks after installation).
ALWAYS use insulated copper wires rated for 90°C (194°F) and 600 V minimum. Do not use aluminum.
ALWAYS wire all circuits as Class 1, electric light & power circuits.
ALWAYS mount the thermostat to a grounded electrical box.
ALWAYS seek help if a problem arises. If ever in doubt about the correct installation procedure, or if the product appears to be damaged, the factory must be contacted before proceeding with the installation.
To prevent the risk of personal injury and/or death, make sure power is not applied to the product until it is fully installed and ready for final testing. All work must be done with power turned off to the circuit being worked on.
To reduce the risk of electric shock, do not connect to a circuit operating at more than 150 V to ground.
Pull power supply wiring to the control location.
Make sure 120 VAC is supplied to 120 VAC cables and 240 VAC is supplied to 240 VAC mat or wire. Otherwise, dangerous overheating and a fire hazard could result. Do not exceed 15-amps on this control.
SunStat® R4 Relays are used when more than 15 A must be controlled by one ConnectPlus thermostat. The ConnectPlus can connect wirelessly to the R4 Relay (see Operation > Wireless Pairing). If a wired connection is desired, follow these steps.
A short or 24 VAC applied between the AWAY and COM terminals will switch the thermostat into 'Away' mode.
The ConnectPlus provides a dry contact output, rated at 30 VAC, 1 A, for second stage heat to be activated when the room temperature dwells below the setpoint. Room control mode only.
Before connecting the wires to the back of the thermostat, detach the display front from the base.
While holding the base section in one hand, with the other pull gently up holding the sides of the thermostat towards the bottom (near RESET button), pivoting away from the base.
Sensor, R4 Relay, Home Automation, and Second Stage connections are made to the terminal block by inserting the wires into the openings and tightening the screws. Three holes are provided for wire access from the back. Wires must be routed in the channel to the right of the terminal block so that the display front can be re-attached. Any low voltage wiring that passes through the inside of the electrical box must be rated at least 90°C 300 V.
Make sure the wire connections are secure by gently tugging on them. Otherwise, arcing could occur, causing dangerous overheating and a possible fire hazard.
Make sure the mortar has had time to fully cure before operating the system for more than a brief test.
A - Tap here to change the display
B - Wi-Fi Status
Tap to access settings
C - Menu
Tap to open
D - Chevrons
Tap to adjust the setpoint
Swipe left/right to change the Home Screen Setpoint/Weather/Clock
Tap pin on Weather/Clock to pin as the Home Screen on screen wakeup
![]() | Notifications | |
HOME/AWAY | ||
Away | On, Off | |
Floor Away | Off, 40°F (4.5°C) to Floor Max | |
Room Away | Off, 40°F (4.5°C) to Room Max | |
SETTINGS | ||
Temperature | ||
Units | °F, °C | |
Floor Max | 40°F to 99°F (4.5°C to 37°C) | |
Room Max | Off, 60°F to 95°F (15.5°C to 35°C) | |
Control | Floor, Room | |
Weather Compensation | On, Off | |
Warm Weather Shut Down | Off, 40°F to 99°F (4.5°C to 37°C) | |
Floor Offset | Off, -5°F to 5°F (-2.5°C to 2.5°C) | |
Room Offset | Off, -5°F to 5°F (-2.5°C to 2.5°C) | |
Date & Time | ||
24-Hour Time | On, Off | |
Set Automatically | On, Off | |
Date | ||
Time | ||
Time Zone | HT, AKT, PT, MT, CT, ET, AT, NT | |
Daylight Savings | On, Off | |
Wi-Fi | ||
Wi-Fi | On, Off | |
Network | ||
Signal Strength | ||
Services & Voice | ||
Weather | ZIP/Postal Code | |
Watts Home | Connect to mobile app | |
Voice Control | Info on setup | |
Display | ||
Language | English, Español, Français | |
Orientation | Portrait, Landscape | |
Brightness | 30% to 100% | |
Timeout | Never, 30 sec, 1 min, 2 min, 5 min | |
Night Light | Off, 30% to 100% | |
Pair Devices (# paired) | Wireless pairing mode | |
Reset | ||
Factory Reset | Delete all settings, reload factory defaults | |
Unpair Devices | Unpair wireless devices | |
Reboot Device | Reset device | |
SCHEDULE | ||
Schedule | On, Off | |
Smart Start | On, Off | |
(days) | Edit Wake/Return/Leave/Sleep settings | |
Change Days | Create new schedule | |
Usage | YEARLY, WEEKLY | |
ABOUT | ||
Model Name | ||
Model Number | ||
Software | ||
Event Log | ||
POWER | ||
Power Off | Touch display for power on option | |
Cable/Mat Voltage | 120 V, 240 V | |
Cable/Mat Current | 1 A to 15 A | |
Second Stage | Off, 2°F to 10°F (1°C to 5.5°C), 0 min to 60 min | |
Momentary Test | Test system against Cable/Mat Voltage & Current | |
Diagnostics | Voltage, Amp Draw, Sensor readings |
By default, the ConnectPlus controls the heating system to maintain the floor temperature at the setpoint of 85°F (29°C). Room temperature control can be selected in the Temperature Settings. Floor and Room maximum settings are also available to limit temperatures.
Before first using the Wi-Fi features of this product, you must accept the Terms of Use, as amended from time to time and available at https://www.watts.com/terms-of-use. If you do not accept these terms, this product can still be used without Wi-Fi features.
It is strongly recommended that a qualified, licensed electrician install the heating cables and related electrical components. If problems with the system arise, please consult the troubleshooting guide below.
Any electrical troubleshooting work should be performed with the power removed from the circuit, unless otherwise noted.
Problem | Possible Cause | Solution |
Wi-Fi connected but weather info missing | Unknown location | Enter ZIP/Postal Code Menu > Settings > Services & Voice > Weather |
Heating (orange setpoint screen), but floors do not feel warm | Setpoint too low to feel warm to the touch | Increase the setpoint |
Faulty wiring | Have the sensor and power lead wiring checked by a certified electrician | |
Display is off | Thermostat in off mode | To resume operation, touch the display for power on option |
Power off at the breaker | Check the breaker or fuse in the electrical panel supplying power to the thermostat | |
Faulty Wiring | Have the power supply wiring checked by a certified electrician | |
Heat is on before the scheduled time | Smart Start feature enabled | Floor heating will begin early to meet the scheduled temperature on time |
Memory Error | Thermostat cannot read its settings | Verify all settings or reload factory defaults Menu > Settings > Reset > Factory Reset |
Floor Sensor Error | Faulty sensor or wiring | Have the sensor resistance and wiring checked by a certified electrician |
Replace wired sensor | ||
Pair ConnectPlus Smart Sensor and accept to use as floor temperature |
Power supply | 120/240 VAC, 60 Hz, 3 W |
Maximum load | 15 A, resistive |
Maximum power | 1800 W at 120 VAC |
3600 W at 240 VAC | |
GFCI | Class A (5 mA trip) |
Dimensions | 4.73" H x 3.11" W x 1.9" D (120 x 79 x 48 mm) |
0.620" D (16 mm) from wall | |
Approvals | UL 943, UL/CSA 60730, UL 991 |
Ambient conditions | 32°F to 86°F (0°C to 30°C), < 90% RH non-condensing |
Floor Sensor | Thermistor, 10kΩ NTC type, 300 V jacketed cable, 15 ft |
Limited 3 Year Warranty
SunTouch warrants this control (the product) to be free from defect in material and workmanship for a period of (3) years from the date of original purchase from authorized dealers. During this period, SunTouch will replace the product or refund the original cost of the product at SunTouch's option, without charge, if the product is proven defective in normal use. Please return the control to your distributor to begin the warranty process.
This limited warranty does not cover shipping costs. Nor does it cover a product subjected to misuse or accidental damage. This warranty does not cover the cost of installation, diagnosis, removal or reinstallation, or any material costs or loss of use.
This limited warranty is in lieu of all other warranties, obligations, or liabilities expressed or implied by the company. In no event shall SunTouch be liable for consequential or incidental damages resulting from installation of this product. Some states or provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above exclusions or limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights that vary from state to state.
SunTouch Customer Support
USA Toll-free: (888) 432-8932
Canada Toll-free: (888) 208-8927
Latin America Tel: (52) 81-1001-8600
SunTouch.com
©2022 Watts