York LX Series Technical Manual page 35

Split system air conditioners
Hide thumbs Also See for LX Series:
Table of Contents

Advertisement

COOLING CAPACITY - With High Efficiency Motor Furnaces
UNIT
MODEL
MODEL
YCD36B23S
TM8E120C16MP11
YCD36B23S
TM8E120C16MP11
YCD36B23S
TM8E120C16MP11
YCD36B23S
TM8E120C16MP11
YCD36B23S
TM8E120C16MP11
YCD36B23S
TM8E120C16MP11
YCD36B23S
TM8E120C20MP11
YCD36B23S
TM8E120C20MP11
YCD36B23S
TM8E120C20MP11
YCD36B23S
TM8E120C20MP11
YCD36B23S
TM8E120C20MP11
YCD36B23S
TM8E120C20MP11
YCD36B23S
TM8E130D20MP11
YCD36B23S
TM8E130D20MP11
YCD36B23S
TM8E130D20MP11
YCD36B23S
TM8V060A12MP11C
YCD36B23S
TM8V060A12MP11C
YCD36B23S
TM8V060A12MP12C
YCD36B23S
TM8V060A12MP12C
YCD36B23S
TM8V080B12MP11C
YCD36B23S
TM8V080B12MP11C
YCD36B23S
TM8V080B12MP11C
YCD36B23S
TM8V080B12MP11C
YCD36B23S
TM8V080B12MP11C
YCD36B23S
TM8V080B12MP12C
YCD36B23S
TM8V080B12MP12C
YCD36B23S
TM8V080B12MP12C
YCD36B23S
TM8V080B12MP12C
YCD36B23S
TM8V080B12MP12C
YCD36B23S
TM8V080C16MP11C
YCD36B23S
TM8V080C16MP11C
YCD36B23S
TM8V080C16MP11C
YCD36B23S
TM8V080C16MP11C
YCD36B23S
TM8V080C16MP11C
YCD36B23S
TM8V080C16MP11C
YCD36B23S
TM8V080C16MP12C
YCD36B23S
TM8V080C16MP12C
YCD36B23S
TM8V080C16MP12C
YCD36B23S
TM8V080C16MP12C
YCD36B23S
TM8V080C16MP12C
YCD36B23S
TM8V080C16MP12C
YCD36B23S
TM8V100C16MP11C
YCD36B23S
TM8V100C16MP11C
YCD36B23S
TM8V100C16MP11C
YCD36B23S
TM8V100C16MP11C
YCD36B23S
TM8V100C16MP11C
YCD36B23S
TM8V100C16MP11C
YCD36B23S
TM8V100C16MP12C
YCD36B23S
TM8V100C16MP12C
YCD36B23S
TM8V100C16MP12C
YCD36B23S
TM8V100C16MP12C
YCD36B23S
TM8V100C16MP12C
YCD36B23S
TM8V100C16MP12C
Johnson Controls Ducted Systems
FURNACE
WIDTH
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
24.5
24.5
24.5
14.5
14.5
14.5
14.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
1
(Continued)
COIL
RATED
2
MODEL
CFM
CF/CM/CU36C
1125
CF/CM/CU42C
1125
CF/CM/CU48C
1125
CF/CM/CU48D
1125
CF/CM36D
1125
CF/CM42D
1125
CF/CM/CU36C
1275
CF/CM/CU42C
1275
CF/CM/CU48C
1300
CF/CM/CU48D
1300
CF/CM36D
1300
CF/CM42D
1300
CF/CM/CU48D
1300
CF/CM36D
1300
CF/CM42D
1300
CF/CM/CU36B
975
CF42B
975
CF/CM/CU36B
975
CF42B
975
CF/CM/CU36B
1000
CF/CM/CU36C
1000
CF/CM/CU42C
1000
CF/CM/CU48C
1000
CF42B
1000
CF/CM/CU36B
1000
CF/CM/CU36C
1000
CF/CM/CU42C
1000
CF/CM/CU48C
1000
CF42B
1000
CF/CM/CU36C
1050
CF/CM/CU42C
1050
CF/CM/CU48C
1050
CF/CM/CU48D
1050
CF/CM36D
1050
CF/CM42D
1050
CF/CM/CU36C
1050
CF/CM/CU42C
1050
CF/CM/CU48C
1050
CF/CM/CU48D
1050
CF/CM36D
1050
CF/CM42D
1050
CF/CM/CU36C
1050
CF/CM/CU42C
1050
CF/CM/CU48C
1050
CF/CM/CU48D
1050
CF/CM36D
1050
CF/CM42D
1050
CF/CM/CU36C
1050
CF/CM/CU42C
1050
CF/CM/CU48C
1050
CF/CM/CU48D
1050
CF/CM36D
1050
CF/CM42D
1050
5752570-YTG-C-1020
COOLING
NET MBH
SEER
TOTAL
SENS.
36.0
27.5
14.00
36.0
27.4
14.00
36.0
27.6
14.25
36.0
27.6
14.25
36.0
27.5
14.00
36.0
27.4
14.00
36.0
29.1
14.00
36.0
29.1
14.00
36.0
29.4
14.25
36.0
29.4
14.25
35.4
27.2
13.50
36.0
29.6
14.00
36.0
29.6
14.25
35.4
27.2
13.50
36.0
29.6
14.25
34.8
25.4
13.50
35.4
25.4
13.50
34.8
25.4
13.50
35.4
25.4
13.50
34.8
25.5
13.25
34.8
25.4
13.25
35.4
25.6
13.25
35.4
25.8
13.50
35.2
25.4
13.25
34.8
25.5
13.25
34.8
25.4
13.25
35.4
25.6
13.25
35.4
25.8
13.50
35.2
25.4
13.25
35.6
26.6
14.00
36.0
26.4
14.00
36.0
26.6
14.25
36.0
26.6
14.25
35.6
26.6
14.00
36.0
26.4
14.00
35.6
26.6
14.00
36.0
26.4
14.00
36.0
26.6
14.25
36.0
26.6
14.25
35.6
26.6
14.00
36.0
26.4
14.00
35.6
26.6
14.00
36.0
26.4
14.00
36.0
26.6
14.25
36.0
26.6
14.25
35.6
26.6
14.00
36.0
26.4
14.00
35.6
26.6
14.00
36.0
26.4
14.00
36.0
26.6
14.25
36.0
26.6
14.25
35.6
26.6
14.00
36.0
26.4
14.00
EER
12.00
12.00
12.25
12.00
12.00
12.00
12.00
12.00
12.00
12.00
11.50
12.00
12.25
11.75
12.25
11.75
11.75
11.75
11.75
11.50
11.50
11.50
11.75
11.50
11.50
11.50
11.50
11.75
11.50
12.00
12.00
12.25
12.25
12.00
12.00
12.00
12.00
12.25
12.25
12.00
12.00
12.00
12.00
12.25
12.25
12.00
12.00
12.00
12.00
12.25
12.25
12.00
12.00
35