Standard RAM bracket Safety information TeeJet Technologies is not responsible for damage or physical harm caused by failure to adhere to the following safety requirements. As the operator of the vehicle, you are responsible for its safe operation.
Page 5
DynaJet Flex ® Figure 3: System diagram - standard mode 98-05334-EN R2...
DynaJet Flex ® INSTALLATION – STANDARD MODE DynaJet® drivers Nozzle harnesses There will be one DynaJet driver 78-05122 per boom section with a When installing nozzle harnesses 45-05935-xx-xx always start with limit of 20 nozzles per section. section 1 and continue to the last section. •...
DynaJet Flex ® Pressure sensor interface kit DynaJet® interface The DynaJet system requires pressure sensor interface kit 90-04007 The DynaJet interface 78-05106 connects to the Sentry interface or 98-04008 to be installed. harness 45-10148: • The pressure sensor interface kit should be mounted close to The Sentry interface harness connects to the boom manifold.
TeeJet customer service representative for clarification before installation. TeeJet technologies is not responsible for misuse or incorrect installation of the system.
Page 9
DynaJet Flex ® Figure 4: System diagram - high flow mode 98-05334-EN R2...
Page 10
DynaJet Flex ® Item Part # Description Illustration 90-02887 DynaJet 7120 console 45-05900: 1.5 m Console extension cable 45-05901: 3 m 45-05902: 6 m 45-05903: 12 m 45-10177 DynaJet interface harness 78-05123 DynaJet HF interface 45-05857: 1 m CAN extension cable 45-05858: 2 m 45-05859: 4 m 45-05864: 10.5 m...
DynaJet Flex ® INITIAL STARTUP This section will explain basic setup of the values required for first-time setup of a DynaJet Flex system. When these settings are completed, initial operation and fine-tuning should be possible. To access setup menu from the work screen, touch center of the screen. 1.
DynaJet Flex ® Units Nozzle selection Sets the units to us (PSI) or metric (bar) Accesses the nozzle selection process to select which nozzle is to be used. At this time only TeeJet nozzles are supported. Figure 8: Units Figure 11: Nozzle selection Number of sections Set the number of boom sections.
DynaJet Flex ® Ready to pressure test the system 1. Ensure that current rate control system is operating at the 4. Switch the master switch ON (on rate control or other boom optimum level. Set DynaJet operating mode to manual and set section control switches) and individual sections one at a time PWM duty cycle at 100%.
DynaJet Flex ® USER SETTINGS Figure 14: Work screen - standard mode If there are questions concerning the setup of the Current droplet size PWM duty cycle Actual pressure DynaJet Flex, please contact your dealer or TeeJet customer service representative for clarification before operation. TeeJet technologies is not responsible for misuse or incorrect operation of the system.
Page 15
DynaJet Flex ® Number of nozzles (high flow mode only) Fine gain Set the number of nozzle locations for each boom section. Allows the control system to make minor adjustments when close to Range is 1 to 120. the target, with the goal of stable pressures and minimal overshoot of target.
DynaJet Flex system. Do not adjustments to pressure regulation. Once coarse gain has alter these settings unless directed by TeeJet Technologies support brought pressure near target; coarse gain off and fine gain will personnel.
DynaJet Flex ® DYNAJET® NOZZLE SELECTION Selection of the proper spray nozzle for use with the DynaJet system is much like selecting the spray nozzle for a traditional spraying operation. Along with the extra application flexibility, DynaJet brings a few other nozzle-related considerations that will be summarized below. 1.
DynaJet Flex ® Nozzle selection example These columns show flow rates at various These columns show droplet sizes pressures. The Delta P represents pressure loss for different styles of spray nozzle at Just like a normal nozzle chart, these columns show rates through the DynaJet solenoid valve, and the given pressures.
DynaJet Flex ® 55295 E-CHEMSAVER® MAINTENANCE INSTRUCTIONS The 55295 e-ChemSaver is a solenoid-actuated shutoff compatible with a wide range of TeeJet nozzle bodies equipped with a diaphragm check valve. It can be used for end-of-boom nozzles as well as individual nozzle shutoff and PWM controls. The valve is normally closed and opens when the solenoid is energized.