Ventilation fan

Advertisement

ASSEMBLY INSTRUCTIONS
6. INSTALL ROUND DUCTWORK
Connect the round ductwork (not included) to the damper/duct connector, and run
the ductwork to a roof or wall cap (not included).
Using tape (not included), secure all the ductwork connections so that they are air
tight.The ducting from this fan to the outside of building has a strong effect on the air
flow, noise and energy use of the fan. Use the shortest, straightest duct routing
possible for best performance, and avoid installing the fan with smaller ducts than
recommended. Insulation around the ducts can reduce energy loss and inhibit mold
growth. Fans installed with existing ducts may not achieve their rated air flow.
CONNECT ELECTRICAL WIRING
Run 120V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the
wiring plate. Refer to the wiring diagram, and connect the wires as shown.
SWITCH I
SWITCH II
BLK
WHT
LINE
GRD
IN
SWITCH BOX
INSTALL GRILLE
Install ceiling material to complete the ceiling construction. Then, cut around the fan
housing.
To attach the grille assembly to the fan housing, pinch the grille springs on the sides
of the grille assembly, and position the grille into the housing with the grille springs in
the appropriate slots. Push the grille assembly towards the ceiling to secure.
SERVICE PARTS
Duct Collar w/damper x 1
WARNING: Ensure that the fan is switched off from the supply mains before replacing.
WARRANTY
QuFresh warrants this product to be free from defects in materials and workmanship for a period of one year from the date of purchase. Warranty does
not apply to product which fails due to abuse, misuse, incorrect installation or improper maintenance. During the one-year warranty period, QuFresh will
repair or replace, at its option, any product or part which has a factory defect in workmanship or materials.
The foregoing shall constitute our sole and exclusive warranty and our sole and exclusive liability, and is in lieu of any other warranties, whether written,
oral, implied or statutory. Under no circumstances will QuFresh be liable for incidental or consequential damages occurring in connection with the use or
performance of the product or other indirect damages with respect to loss of profits, revenue or property or cost of removal, installation or reinstallation.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long
an implied warranty lasts, so the above exclusions may not apply to you.
This warranty gives you specific legal rights and you may have other rights which vary from state to state and province to province.
BRN
FAN
BLK
WHT
GRD
UNIT
Grill x 1
BLACK (BLK)
GROUND (GRD)
SWITCH I
SWITCH II
SWITCH BOX
POWER SUPPLY
120V AC
4
WHITE (WHT)
BROWN (BRN)
WIRE
UNIT
PANEL
FAN
RECEPTACLE
Blower assy x 1