DOC DESC: Model 851 User Manual SEPTEMBER2022. REVISION: 04 COPYRIGHT Copyright 2014 - 2022 Applied Physics Systems Incorporated. All Rights Reserved. The contents of this manual may not be reprinted in part or whole without permission. The contents of this manual are subject to change without notice.
(such as sandstones and limestones), which are generally less radioactive than nonporous strata (such as shales). The Model 851 gamma sensor can be used as either a standalone system or in conjunction with Model 850 directional sensors: •...
DOC PN: 260-0922 DOC DESC: Model 851 User Manual SEPTEMBER2022. REVISION: 04 2 - SYSTEM SPECIFICATIONS This section describes the system specification for the Model 851 Gamma Sensor. Table 1. Model 851 Gamma Sensor Specifications Electrical Input Voltage Range +15 V to +30 V...
SEPTEMBER2022. REVISION: 04 3 - MECHANICAL FEATURES A drawing of the Model 851 Sensor is shown in Figure 1. When used in pulser or EM MWD systems, usually the Model 851 is mechanically connected directly to a Model 850 directional sensor and mounted in a cylindrical pressure barrel. An overlap mechanical connection using four 8-32 stainless steel screws is used to attach the Model 851 to the Model 850 directional sensor.
Not used Communication with the Model 851 is accomplished via the TTL-level serial communications lines shown in Table 2. The Model 851 can be connected to a PC for testing if a TTL-to-RS232 conversion box is inserted in the communication lines between the Model 851 and PC.
9600 using 8-bit data words with one stop bit and no parity bit. An easy method of communicating with the Model 851 is to use a PC running a terminal emulator program such as Windows HyperTerminal or ProComm. When...
ASCII data request commands • Configuration commands To send a data request command to the 851 system, enter the command token <Ctrl/F> (pressing the Ctrl key and the f key simultaneously) followed by one of the keyboard commands listed in Table 3. Press Enter to send the command.
DOC PN: 260-0922 DOC DESC: Model 851 User Manual SEPTEMBER2022. REVISION: 04 Table 3. Model 851 Data Request Commands Keyboard Hex Command Command Result Command 0x30 Send 851 identity data (see Section 6.1.1 for more information) 0x31 Send binary count data in binary format (see Section 6.1.2 for more information)
DOC PN: 260-0922 DOC DESC: Model 851 User Manual SEPTEMBER2022. REVISION: 04 6.1.1 - ID COMMAND (KEYBOARD COMMAND 0, 0X30 HEX) The data in this command is the ASCII string "01Gamma 004" which identifies the unit. Example of a 0x30 response: 06 30 30 31 47 61 6D 61 20 30 30 34 0A 58 A7 06 04 Table 4 explains the contents of this sample data response packet.
DOC PN: 260-0922 DOC DESC: Model 851 User Manual SEPTEMBER2022. REVISION: 04 Example of a 0x31 response: 06 31 00 02 57 AD 00 00 01 D2 01 01 BB 19 06 04 The table below explains the contents of this response: Table 5.
DOC PN: 260-0922 DOC DESC: Model 851 User Manual SEPTEMBER2022. REVISION: 04 commands or set to a user defined time by using the wa command (see Section 6.3 for an explanation of these commands). An example of the binary command...
273 so the rate is 273/10.2=26.8 cps. When the ASCII rate command is received the 851 sensor responds by sending the time and number of counts since the last ASCII rate command. The time and count values are then zeroed so that time and count accumulation can restart.
Enter key. The Model 851 system has 22 configuration commands. Many of these commands should only be used during the calibration of the 851 system. See Appendix A for a complete list of configuration commands. The table below contains the...
These factors tend to reduce the count rate recorded by the 851 sensor from the true borehole formation count rate. The true borehole count rate must be determined; to do so, correct the Model 851 count rate for the following factors: •...
DOC PN: 260-0922 DOC DESC: Model 851 User Manual SEPTEMBER2022. REVISION: 04 greater. Generally the drill collar will produce the largest correction factor. These correction factors are described in more detail below. 7.1 - PRESSURE BARREL CORRECTION (PB CORRECTION) The following two graphs show pressure barrel correction factors using inch and centimeter units.
DOC PN: 260-0922 DOC DESC: Model 851 User Manual SEPTEMBER2022. REVISION: 04 Figure 4. Pressure Barrel Correction Factors in Centimeters If a pressure barrel is manufactured with a metal other than beryllium copper (density 8.2 gram/cm³) then the PB correction factor should be multiplied by the ratio of the density of the new metal divided by the density of beryllium copper.
Page 21
DOC PN: 260-0922 DOC DESC: Model 851 User Manual SEPTEMBER2022. REVISION: 04 Collar ID (cm), cid 2. Collar OD (cm), cod 3. Bit diameter (cm), bit 4. Mud density (gram/cm), md 5. Collar density (gram/cm), cd The BF is given by the following equation: BF=(7 + (md * (cid-4.445)/2)) + (cd*(cod-cid)/2) +(md*(bit-cod)/2)
DOC DESC: Model 851 User Manual SEPTEMBER2022. REVISION: 04 8 - NET SYSTEMS The Applied Physics Systems .NET protocol is based on a polled protocol and is implemented by means of a two-wire serial data link, which is connected in parallel to all auxiliary sensors.
DOC PN: 260-0922 DOC DESC: Model 851 User Manual SEPTEMBER2022. REVISION: 04 8.1 - NET PACKET DESCRIPTION Each NET packet containing data is a short string of bytes, with the following format: <Token> <Command> <data1> <data2>…<dataN> <CRCL> <CRCH> <token> <Eot>...
DOC PN: 260-0922 DOC DESC: Model 851 User Manual SEPTEMBER2022. REVISION: 04 <0x01> <0x73> <0x06> <0x06> <0x19> <0x06> <0x06> <0x06> <0x06> <0x56> Note that the double token becomes four tokens, each pair in the transmitted string representing one token in the original message.
An example of a command response from the Model 851gamma sensor is shown below. The data request command sent by the NET master (usually a directional sensor) to the 851 system is two bytes: <06> <0x31>. The response is of the form: <0x06> <0x31> <Time> <Count> <mx> <my> <CRC> <0x06><0x04>...
Page 26
DOC PN: 260-0922 DOC DESC: Model 851 User Manual SEPTEMBER2022. REVISION: 04 The same routine can be used to check the CRC. Again, start with the CRC=0, and update the CRC with each byte received. After the last data byte, the received CRC itself is used to update the CRC being computed.
DOC DESC: Model 851 User Manual SEPTEMBER2022. REVISION: 04 A - MODEL 851 CONFIGURATION COMMAND REFERENCE A complete listing of the Model 851 configuration commands is shown in Table 11 below. Table 11. Model 851 Configuration Commands Keyboard Command Result...
Page 29
DOC PN: 260-0922 DOC DESC: Model 851 User Manual SEPTEMBER2022. REVISION: 04 There are two Help commands, ch and wh. Below are samples of the Help output: • Configuration Command Help With Config Parameter, Command: 'contrl+f''c''x''parameter' (contrl+f means hold down control key and type f key)