Warmsource-E does not exceed 90ºF (32ºC) during operation. Warmboard Comfort System (WCS) MUST be installed by a licensed general contractor, heating professional or plumber. Failure to use a properly licensed installer, failure to use the...
While every project is different, this list can be a While every project is different, this list can be a are pre-commissioned, temperatures are pre-set, helpful when working with Warmboard-S and WCS. helpful when working with Warmboard-R and WCS. and network devices are pre-configured; everything is plug-and-play.
PLUMBING & MECHANICAL 1.800.556.0595 for assistance Included, Pre-Plumbed WCS Design Drawings The following components are pre-plumbed Our WCS Design Drawings list all the necessary inside the Warmsource-E unit: plumbing and mechanical materials. Reference this document regularly. Before proceeding, make sure Automatic air vent all boiler components are pre-plumbed per the Electro Boiler Manual, including:...
WARMSOURCE-E PREPARATION WARMBOARD COMFORT SYSTEM // ELECTRIC Install Location Minimum Clearances Before installing Warmsource-E, it’s important This illustration shows the recommended minimum to consider its location. Like all electric boilers, dimensions for the Warmsource-E mechanical room. Warmsource-E does make a small amount of noise,...
WARMSOURCE-E INSTALLATION WARMBOARD COMFORT SYSTEM // ELECTRIC Securing Warmsource-E Double check code clearances and minimum clearance dimensions (pg.4) To secure Warmsource-E to the wall, install two, 2" x 4" x 25" wood sleepers to the wall studs, then fasten the unit into place (Warmsource-E...
FILLING & PURGING 1.800.556.0595 for assistance Propylene Glycol To fill Warmsource-E and the manifold 1 loops Once the system is plumbed and pressure tested with with water (city or well supply), lift the fast fill lever air (T&M Installation Guide), the next step is to fill the In some situations, it may be necessary to add on the pressure reducing valve E system with water and purge the air in the lines.
CONSTRUCTION MODE WARMBOARD COMFORT SYSTEM // ELECTRIC Step 6: Return to each manifold and adjust the flow Once the system is filled properly with water, rates of each loop put Warmsource-E in “Construction Mode”, an operating state that supplies heat to the structure...
Refer to the WCS Design Drawings as needed and those displayed in your WCS Design Drawings. Controls Warmboard Controls consist of the following: 120 VAC thermostats (one per heating zone) 120 VAC Manifold Controller (one per manifold) 24 volt solenoid valve actuators (one per loop)
THERMOSTATS WARMBOARD COMFORT SYSTEM // ELECTRIC Thermostat Installation Warmboard Comfort System offers 3 different types of thermostats: Every thermostat MUST be installed in the location Heating specified in the WCS Design Drawings. Failure to Controls the heat in one zone of the house do so will cause the system to behave inaccurately.
AIR CONDITIONING 1.800.556.0595 for assistance AC Installation Warmboard thermostats offer single-stage air conditioning. Connecting an AC system to WCS is very similar to wiring a 24v thermostat from an AC unit, just follow the steps below. Remove the front cover from Warmsource-E Locate terminal connection “AC1/Fan”...
(Manifold Controllers, actuators, thermostats) Next, tap the button in the lower right corner Match the specifications in the Warmboard Design and choose “Tutorial” to familiarize yourself with Once these steps have been completed sequentially, Drawings for each loop and zone to ensure the the controls proceed to the next steps.
Page 14
Failure to stringently adhere to any of the recommended procedures of this installation guide and/or any other Warmboard document related to this product shall release Warmboard of all liability with respect to this product or the use thereof. For complete warranty information please call 1.800.556.0595 or visit warmboard.com...
Need help?
Do you have a question about the COMFORT SYSTEM and is the answer not in the manual?
Questions and answers