MATALA VersiFlow Series Instruction And Maintenance Manual

MATALA VersiFlow Series Instruction And Maintenance Manual

Advertisement

VersiFlow Series
High Flow Multi-Purpose "Versatile " Pump
V-3200
V-3900
V-4700
V-5600
Instruction and Maintenance Manual
1/5HP 150W / Discharge 2"
1/3HP 250W / Discharge 2"
1/2HP 400W / Discharge 2"
1HP 750W / Discharge 2"
Matala
-1-
"Make water alive"
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VersiFlow Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MATALA VersiFlow Series

  • Page 1 VersiFlow Series High Flow Multi-Purpose "Versatile " Pump V-3200 1/5HP 150W / Discharge 2” V-3900 1/3HP 250W / Discharge 2” V-4700 1/2HP 400W / Discharge 2” V-5600 1HP 750W / Discharge 2” Instruction and Maintenance Manual Matala ® “Make water alive”...
  • Page 2: Table Of Contents

    Introduction Thank you for selecting the VersiFlow Series High Flow Multi-Purpose “ Versatile” Pump. This instruction manual explains the product operations and gives important precautions regarding its safe use. In order to use the product to maximum benefit, be sure to read the instructions thoroughly and follow them carefully.
  • Page 3: Prior To Operation

    Prior to Operation Check the following points upon receipt of your pump: Is the pump exactly what you ordered? Check nameplate. It is especially important that you check whether the pump is to be used with 50 or 60 Hz. Has any damage occurred during shipment? Are any bolts or nuts loose? Have all necessary accessories been supplied? (For a list of standard accessories see Construction.)
  • Page 4: Installation

    4. A permanent ground connection from pump to the grounding bar at the service panel is mandatory, Matala Pump sump pumps come with a grounding conductor and a grounding-type attachment plug. Do not connect pump to a power supply until permanently grounded. For maximum safety, connect pump to a circuit equipped with a Ground Fault Circuit Interrupter device when you position the pump's grounding wire.
  • Page 5: Electrical Wiring

    THIS WARRANTY DOES NOT COVER DAMAGE DUE TO LIGHTNING OR OTHER CONDITIONS BEYOND THE CONTROL OF Matala Pump. LABOR & COSTS : Matala Pump shall in no event be liable for the cost of field labor to other charges incurred by any customer in removing and/or reaffixing any Matala Pump product, parts or component.
  • Page 6: Troubleshooting

    Troubleshooting Problems Possible Causes * Line circuit breaker is off, or fuse is burned or loosed. * Water level in sump has not reached turn-on level as indicated Pump dose not in installation drawing. run and hums * Pump cord is not making contact in receptacle. * Float (optional) is stuck.

This manual is also suitable for:

Versiflow v-3200Versiflow v-3900Versiflow v-4700Versiflow v-5600