MATALA GeyserHi-Flow Series Instruction And Maintenance Manual

MATALA GeyserHi-Flow Series Instruction And Maintenance Manual

Waterfall pump

Advertisement

GeyserHi-Flow Series
 GHF-9000
 GHF-13000
 GHF-18000
Instruction and Maintenance Manual
Introduction
Thank you for selecting the GeyserHi-Flow Series Waterfall Pump.
This instruction manual explains the product operations and gives important
precautions regarding its safe use. In order to use the product to maximum benefit, be
sure to read the instructions thoroughly and follow them carefully.
To avoid accident, do not use the pump in any way other than as described in this
instruction manual especially when you see
manual, keep it nearby as a reference in case questions arise during use.
If this instruction manual should become lost or damaged, ask your nearest dealer or
representative for another copy.
Waterfall Pump
1HP 750W / Discharge 3"
1-1/2HP 1125W / Discharge 3"
2HP 1500W / Discharge 3"
! WARNING
. After reading this instruction
Matala
"Make water alive"
-1-
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GeyserHi-Flow Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MATALA GeyserHi-Flow Series

  • Page 1 2HP 1500W / Discharge 3” Instruction and Maintenance Manual Introduction Thank you for selecting the GeyserHi-Flow Series Waterfall Pump. This instruction manual explains the product operations and gives important precautions regarding its safe use. In order to use the product to maximum benefit, be sure to read the instructions thoroughly and follow them carefully.
  • Page 2: Table Of Contents

    Contents ___________  Construction and Parts List…………... 2  Prior to Operation ………………………. 3  Specification …………………………….. 3  Installation ……………………………….. 4  Electrical Wiring …..……… …………… 5  Guarantee …………… ……………...… 5  Troubleshooting ……………………….. Construction and Parts List Description Material Q'ty...
  • Page 3: Prior To Operation

    Prior to Operation Check the following points upon receipt of your pump:  Is the pump exactly what you ordered? Check nameplate. It is especially important that you check whether the pump is to be used with 50 or 60 Hz. ...
  • Page 4: Installation

    4. A permanent ground connection from pump to the grounding bar at the service panel is mandatory, Matala Pump sump pumps come with a grounding conductor and a grounding-type attachment plug. Do not connect pump to a power supply until permanently grounded. For maximum safety, connect pump to a circuit equipped with a Ground Fault Circuit Interrupter device when you position the pump's grounding wire.
  • Page 5: Electrical Wiring

    THIS WARRANTY DOES NOT COVER DAMAGE DUE TO LIGHTNING OR OTHER CONDITIONS BEYOND THE CONTROL OF Matala Pump. LABOR & COSTS : Matala Pump shall in no event be liable for the cost of field labor to other charges incurred by any customer in removing and/or reaffixing any Matala Pump product, parts or component.
  • Page 6: Troubleshooting

    Troubleshooting Problems Possible Causes * Line circuit breaker is off, or fuse is burned or loosed. * Water level in sump has not reached turn-on level as indicated Pump dose not in installation drawing on the carton. run and hums * Pump cord is not making contact in receptacle.