  • Page 1 MD65xx Image Barcode Scanner User Manual Version: MD65xx_UM_EN_V1.1.1...
  • Page 2 Warning: Ensure that the optional DC adapter works at +5V, especially for the RS-232 interface cable. NOTICE: 1. All software, including firmware, furnished to the user is on a licensed basis. 2. The right is reserved to make changes to any software or product to improve reliability, function, or design.
  • Page 3: Table Of Contents

    Contents Technical specifications ............................1 Cable connector pin-outs descriptions........................ 2 Default setting for each barcode .......................... 3 Dimensions ................................5 Parts of the scanner .............................. 6 Introduction to installation ............................. 7 Programming instruction ............................9 Operate the scanner by receiving command via UART ................. 10 Interface selection ..............................
  • Page 4 UK/Plessey................................58 China Post ................................59 GS1 DataBar (GS1 DataBar Truncated) ......................60 GS1 DataBar Limited ............................61 GS1 DataBar Expanded ............................. 62 China Finance ..............................63 PDF417 ................................. 65 MicroPDF417 ................................ 66 QR Code ................................67 Data Matrix ................................68 Han Xin Code ...............................
  • Page 5: Technical Specifications

    Technical specifications Table 1-1 Technical specifications Input voltage 5 VDC ± 0.25V Power 1.60W (working); 0.40W (standby) Current 320mA (working); 80mA (standby) Image size 752 × 480 pixels Scanning angle ± 60° , ± 40° , ± 42° (Skew, Pitch, Roll) UPC-A, UPC-E, UPC-E1, EAN-13, EAN-8, ISBN (Bookland EAN), ISSN, Code 39, Code 39 full ASCII, Code 32, Trioptic Code 39, Interleaved 2 of 5, Industrial 2 of 5, Matrix 2 of 5, Codabar (NW7), Code 128, UCC/EAN 128,...
  • Page 6: Cable Connector Pin-Outs Descriptions

    Cable connector pin-outs descriptions Cable connector interface pin-outs The pin-outs descriptions in Table 1 apply to the cable connector on the scanner and are for reference only. Table 1-2 Cable connector pin-outs descriptions RS232 Keyboard (PS2) Power (+5V) Power (+5V) Power (+5V) +3.3V ( for interface auto Ground (for interface auto...
  • Page 7: Default Setting For Each Barcode

    Default setting for each barcode Table 2 Default setting for each barcode Min. code Read Check digit Check digit Proprietary Code type length enable verification transmission code ID code ID √ √ √ UPC-A (12) √ √ √ UPC-E √ √...
  • Page 8 Min. code Read Check digit Check digit Proprietary Code type length enable verification transmission code ID code ID √ PDF417 √ MicroPDF417 √ DataMatrix √ QR code √ Han Xin Code √ Aztec Code Note: The settings for ISBN/ISSN and EAN-13 must be the same except the code ID. Fixed-length barcodes.
  • Page 9: Dimensions

    Dimensions...
  • Page 10: Parts Of The Scanner

    Parts of the scanner Figure 1 ① Exit window ② LED ③ Trigger ④ Cable interface port...
  • Page 11: Introduction To Installation

    Introduction to installation Note: If any of the below operation is incorrect, turn off the power immediately and check the scanner for any improper connections. Go through all steps again. Installation - keyboard wedge 1. Switch off the host and unplug the keyboard connector. 2.
  • Page 12 Installation - USB The scanner attaches directly to a USB host, and is powered by it. No additional power supply is required. Plug the series A connector in the USB host, or an available port of the terminal. Windows will automatically detect the USB device. Figure 5...
  • Page 13: Programming Instruction

    Programming instruction Important notes: 1. During the process of programming, LED is lighting to indicate the programming correctness. LED will go off if any incorrect programming operation performed. 2. After each successful programming, LED will go off and the scanner will beep twice. 3.
  • Page 14: Operate The Scanner By Receiving Command Via Uart

    Operate the scanner by receiving command via UART Note: 1- The information in this chapter is provided for the scanner with RS232 cable or USB cable. 2- If the scanner is with USB cable, the setting of USB device type must be set as “USB virtual COM”. Please refer to the chapter of “USB interface”.
  • Page 15: Interface Selection

    Interface selection This scanner supports interfaces such as keyboard wedge, RS-232 serial wedge, and USB interface. In most of the cases, simply selecting an appropriate cable provided by the manufacturer will work for a specific interface. Interface selection: Auto detection- By setting this function, the scanner will automatically detect the keyboard wedge, RS-232 or USB interface for user.
  • Page 16: Keyboard Wedge Interface

    Keyboard wedge interface Keyboard type: As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. Keyboard layout: The scanner supports different national keyboard layouts. Clock period: According to the PS2 protocol, the clock is provided by the device, e.g. keyboard or scanner, with the period between 60us to 100us.
  • Page 17 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry IBM AT, PS/2 Keyboard type Apple Mac compatibles Turkish F Turkish Q French Italian Spanish Keyboard layout Slovak Denmark Japanese German Belgian Russian Character encoding system Refer to chapter of “Handheld scan & some global settings” 60us 70us Clock period...
  • Page 18 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry 200us 10ms Delay-after-compound-key 20ms 40ms 80ms Alphabetic key Numeric key Numeric keypad Alt+ keypad Disable Power-on simulation Enable 10ms Inter-character delay 20ms 40ms 80ms Inter-byte delay...
  • Page 19 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Disable Caps Lock reversion Enable Disable Caps Lock override Enable...
  • Page 20: Rs-232 Interface

    RS-232 interface Flow control: None-The communication only uses TxD and RxD signals without any hardware or software handshaking protocol. RTS/CTS- If the scanner wants to send the barcode data to host computer, it will issue the RTS signal first, wait for the CTS signal from the host computer, and then perform the normal data communication. If there is no replied CTS signal from the host computer after the timeout duration, the scanner will issue an error indication.
  • Page 21 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry 80ms 00-99 Response delay 00-99 (100ms) 1200 2400 4800 Baud rate 9600 19200 38400 57600 115200 None Parity bit Even 8 bits Data bit 7 bits One bit Stop bit Two bits...
  • Page 22: Usb Interface

    USB interface USB device type: HID keyboard– By setting, the scanner is used as a USB HID keyboard emulation device. keyboard layout setting follows the setting of keyboard layout in the chapter of Keyboard wedge. USB virtual COM– By setting, the scanner emulate a regular RS232-based COM port. If a Microsoft Windows PC is connected to the scanner, a driver is required to install on the connected PC.
  • Page 23 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry French Italian Spanish Slovak Denmark Japanese German Belgian Russian Character encoding system Refer to chapter of “Handheld scan & some global settings” 10ms Inter-character delay 20ms 40ms 60ms Alphabetic key Numeric key Numeric keypad Alt+ keypad...
  • Page 24: Hand-Held Scan & Some Global Settings

    Hand-held scan & some global settings Scanning mode: Good-read off-The trigger button must be pressed once to activate scanning. The light source of scanner stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed.
  • Page 25 Printable character only- If this option is selected, the scanner will output the printable characters only, i.e. in ASCII from 20H to 7EH. Alphanumeric character only- If this option is selected, the scanner will output the alphanumeric characters only, i.e. “A”-“Z”, “a”-“z”, “0”-“9”. Decoder optimization: If it is enabled, the scanner will optimize the decoder with error correction.
  • Page 26 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Global min. code length for 1D 01-99 01-99 symbol 00-66 Global G1-G6 string selection 00-66 Disable Element amendment Enable None Character output restraint Printable character only Alphanumeric character only Disable Decoder optimization Enable Data output delay in...
  • Page 27: Indication

    Indication Power on alert: After power-on the scanner will generate an alert signal to indicate a successful self-test. LED indication: After each successful reading, the LED above the scanner will light up to indicate a good barcode reading. Beeper indication: After each successful reading, the scanner will beep to indicate a good barcode reading, and its beep tone duration is adjustable.
  • Page 28: Decode Illumination And Decode Aiming Pattern

    Decode illumination and decode aiming pattern Decode illumination mode: Enable illumination causes the scanner to turn on the illumination to aid decoding. Disable illumination to turn off illumination for the scanner during decoding. Better quality images could be obtained with illumination support. The effectiveness of the illumination decreases as the distance to the target increases.
  • Page 29: Dpm, Multiple Symbols, Structured Append, Etc. Read Setting

    DPM, Multiple symbols, Structured append, etc. read setting 2D symbols read: A global setting of 2D symbols readability. DPM format read: By setting Enable, the scanner can read 2D symbols in DPM (Direct Park Marking) format. Some barcodes in DPM format are shown below. Multiple symbols &...
  • Page 30 Vertical centering read: By setting Enable, the scanner reads only the barcode centered by the aimer in vertical direction. However, the scanner will read either one of two barcodes which are positioned horizontally. See example below.
  • Page 31 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Follow respective 2D symbol setting All 2D OFF All 2D ON Only PDF417 ON 2D symbols read Only QR code ON Only Data Matrix ON Only MaxiCode ON Only Aztec Code ON Only Han Xin Code ON Disable DPM format read...
  • Page 32 Note: The instruction of calibrating the aimer in vertical centering direction. Scan the barcode on this page. The scanner will give three musical short beeps to indicate entering calibration mode. Press the trigger of the scanner while maintaining the distance of about 15cm between the exit window of the scanner and this paper.
  • Page 33: Upc-A

    UPC-A Read: Format System character Data digits (10 digits) Check digit Check digit verification: The check digit is optional. Check digit trans.: By setting Enable, check digit will be transmitted. Code ID setting: Code ID is a one-or-two-character string used to represent the symbol upon a succeeding reading.
  • Page 34 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry 00-66 Insert group selection 00-66 None 2 digits Supplement digits 5 digits 2 or 5 digits None Truncate leading zeros Truncation/Expansion Expand to EAN-13 Truncate system character Add country code...
  • Page 35: Upc-E

    UPC-E Read: Format System character “0” Data digits (6 digits) Check digits Check digit verification: The check digit is optional and made as the sum of the numerical value of the data digits. Check digit trans.: By setting Enable, check digit will be transmitted. Code ID setting: Refer to Code ID setting of UPC-A.
  • Page 36 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry None 2 digits Supplement digits 5 digits 2 or 5 digits None Truncate leading zeros Truncation/Expansion Expand to EAN-13 Expand to UPC-A Truncate system character...
  • Page 37: Upc-E1

    UPC-E1 Read: Format Leading zero “1” Following 5 data digits Check digits Check digit verification: The check digit is optional and made as the sum of the numerical value of the data digits. Check digit trans.: By setting Enable, check digit will be transmitted. Code ID setting: Refer to Code ID setting of UPC-A.
  • Page 38 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry 2 digits 5 digits 2 or 5 digits None Truncate leading zeros Truncation/Expansion Expand to EAN-13 Expand to UPC-A Truncate system character...
  • Page 39: Ean-13 (Isbn/Issn)

    EAN-13 (ISBN/ISSN) Read: Format Data digits (12 digits) Check digit Check digit verification: The check digit is optional and made as the sum of the numerical value of the data digits. Check digit transmission: By setting Enable, check digit will be transmitted. EAN-13 code ID setting: Refer to Code ID setting of UPC-A.
  • Page 40 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Disable Read Enable Disable Check digit verification Enable Disable Check digit transmission Enable 00-FF 00-FF EAN-13 code ID setting (ASCII) <A>* 00-66 Insert group selection 00-66 None 2 digits Supplement digits 5 digits 2 or 5 digits Disable...
  • Page 41: Ean-8

    EAN-8 Read: Format Data digits (7 digits) Check digit Check digit verification: The check digit is optional and made as the sum of the numerical value of the data digits. Check digit trans.: By setting Enable, check digit will be transmitted. Code ID setting: Refer to Code ID setting of UPC-A.
  • Page 42 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Disable Read Enable Disable Check digit verification Enable Disable Check digit trans. Enable 00-FF Code ID setting 00-FF (ASCII) <C>* 00-66 Insert group selection 00-66 None 2 digits Supplement digits 5 digits 2 or 5 digits None...
  • Page 43: Code 39 (Code 32, Trioptic Code 39)

    Code 39 (Code 32, Trioptic Code 39) Read: Format ⋆ Data digits (variable) Check digit (optional) ⋆ Check digit verification: The check digit is optional and made as the sum module 43 of the numerical value of the data digits. Check digit transmission: By setting Enable, check digit will be transmitted.
  • Page 44 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Disable Read Enable Disable Check digit verification Enable Disable Check digit transmission Enable 00-99 Max. code length 00-99 00-99 Min. code length 00-99 00-FF Code ID setting 00-FF (ASCII) <M>* 00-66 Insert group selection 00-66...
  • Page 45 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Enable Disable Code 32 Prefix “A” transmission Enable Disable Trioptic Code 39 read Enable Trioptic Code 39 Start/End Disable transmission Enable...
  • Page 46: Interleaved 2 Of 5

    Interleaved 2 of 5 Read: Format Data digits (Variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 10 of the numerical values of all data digits. There are two optional check digit algorithms: the specified Uniform Symbol Specification (USS) and the Optical Product Code Council (OPCC).
  • Page 47 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Disable Read Enable Disable Check digit verification OPCC Disable Check digit transmission Enable 00-99 Max. code length 00-99 00-99 Min. code length 00-99 00-FF Code ID setting 00-FF (ASCII) <I>* 00-66 Insert group selection 00-66...
  • Page 48: Industrial 2 Of 5

    Industrial 2 of 5 Read: Format Data digits (variable) Max./Min. code length: Refer to Max./Min. code length of Code 39. Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A. Multiple-scan setting Single-scan setting Option bar code...
  • Page 49: Matrix 2 Of 5

    Matrix 2 of 5 Read: Format Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 10 of the numerical values of all data digits. Check digit transmission: By setting Enable, check digit will be transmitted. Max./Min.
  • Page 50: Codabar

    Codabar Read: Format Start Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 16 of the numerical values of all data digits. Check digit transmission: By setting Enable, check digit will be transmitted. Max./Min.
  • Page 51 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry 00-66 Insert group selection 00-66 ABCD/ABCD Start/End type abcd/abcd ABCD/TN⋆E abcd/tn⋆e Disable Start/End transmission Enable Disable Start/End character equality Enable...
  • Page 52: Code 128

    Code 128 Read: Format Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 103 of all data digits. Check digit transmission: By setting Enable, check digit will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code 39. Code ID setting: Refer to Code ID setting of UPC-A.
  • Page 53 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Disable Read Enable Disable Check digit verification Enable Disable Check digit transmission Reserved 00-99 Max. code length 00-99 00-99 Min. code length 00-99 00-FF Code ID setting 00-FF (ASCII) <K>* 00-66 Insert group selection 00-66...
  • Page 54: Ucc/Ean 128

    UCC/EAN 128 Read: Format Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 103 of all data digits. Check digit transmission: By setting Enable, check digit will be transmitted. Max. /Min. code length: Refer to Max./Min. code length of Code 39. Code ID setting: Refer to Code ID setting of UPC-A.
  • Page 55 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Read Disable Enable Check digit verification Disable Enable Check digit transmission Disable Reserved Max. code length 00-99 00-99 Min. code length 00-99 00-99 Code ID setting 00-FF 00-FF (ASCII) <K>* Insert group selection 00-66 00-66...
  • Page 56: Isbt 128

    ISBT 128 Read: Format “=” or “&” Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 103 of all data digits. Check digit transmission: By setting Enable, check digit will be transmitted. Max./Min.
  • Page 57: Code 93

    Code 93 Read: Format Data digits (variable) 2 check digits (optional) Check digit verification: The check digit is made as the sum module 47 of the numerical values of all data digits. Check digit transmission: By setting Enable, check digit will be transmitted. Max./Min.
  • Page 58: Code 11

    Code 11 Read: Format Data digits (variable) Check digit 1 (optional ) Check digit 2 (optional) Check digit verification: The check digit is presented as the sum module 11 of all data digits. Check digit transmission: By setting Enable, check digit 1 and check digit 2 will be transmitted upon your selected check digit verification method.
  • Page 59 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Disable Read Enable Disable One digit Check digit verification Reserved Reserved Disable Check digit transmission Enable 00-99 Max. code length 00-99 00-99 Min. code length 00-99 00-FF Code ID setting 00-FF (ASCII) <V>*...
  • Page 60: Msi/Plessey

    MSI/Plessey Read: Format Data digits (variable) Check digit 1 (optional) Check digit 2 (optional) Check digit verification: The MSI/Plessey has one or two optional check digits. There are three methods of verifying check digits, i.e. Mod10, Mod10/10 and Mod 11/10. The check digit 1 and check digit 2 will be calculated as the sum module 10 or 11 of the data digits.
  • Page 61 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Disable Read Enable Disable Check digit verification 1 digit (mod 10) Reserved Reserved Disable Check digit transmission Enable 00-99 Max. code length 00-99 00-99 Min. code length 00-99 00-FF Code ID setting 00-FF (ASCII) <O>*...
  • Page 62: Uk/Plessey

    UK/Plessey Read: Format Data digits (variable) 2 check digits (optional) Check digit verification: The UK/Plessey has one or two optional check digits. The check digit 1 and check digit 2 will be calculated as the sum module 10 or 11 of the data digits. Check digit transmission: By setting Enable, check digit will be transmitted.
  • Page 63: China Post

    China Post Read: Format 11 Data digits Max. /Min. code length: Refer to Max./Min. code length of Code 39. The code length of China Post is Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A. Multiple-scan setting Single-scan setting Option bar code...
  • Page 64: Gs1 Databar (Gs1 Databar Truncated)

    GS1 DataBar (GS1 DataBar Truncated) GS1 DataBar Truncated is structured and encoded the same as the standard GS1 DataBar format, except its height is reduced to a 13 modules minimum; while GS1 DataBar should have a height greater than or equal to 33 modules. Read: Format 16 Data digits...
  • Page 65: Gs1 Databar Limited

    GS1 DataBar Limited Read: Format 16 Data digits Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A. Conversion: Refer to Conversion of GS1 DataBar (GS1 DataBar Truncated). Multiple-scan setting Single-scan setting Option bar code Option...
  • Page 66: Gs1 Databar Expanded

    GS1 DataBar Expanded Read: Format Data characters (variable) Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A. Conversion: UCC/EAN 128- Refer to Code ID transmission of String transmission, ]Cm will be identified as AIM ID. Multiple-scan setting Single-scan setting Option bar code...
  • Page 67: China Finance

    China Finance Note: This type of barcode is not Omni-directionally decodable. The encodable character set includes numeric 0 to 9. Among the symbol of 0 to 9, 0 and 2, 4 and 9, 5 and 8, 6 and 7, have the symmetrical pattern;...
  • Page 68 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Only 6 converted to B Only 7 converted to C Only 8 converted to D Only 9 converted to E Disable Assigned to 0 Assigned to 5(A) Assigned to 6(B) Assigned to 7(C) Leading character assignment Assigned to 8(D)
  • Page 69: Pdf417

    PDF417 Read: Format Data characters (variable) Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Disable Read Enable...
  • Page 70: Micropdf417

    MicroPDF417 Read: Format Data characters (variable) Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Disable Read Enable...
  • Page 71: Qr Code

    QR Code Read: Format Data characters (variable) Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Disable Read Enable...
  • Page 72: Data Matrix

    Data Matrix Read: Format Data characters (variable) Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Disable Read Enable...
  • Page 73: Han Xin Code

    Han Xin Code Read: Format Data characters (variable) Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Disable Read Enable...
  • Page 74: Aztec Code

    Aztec Code Read: Format Data characters (variable) Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Disable Read Enable...
  • Page 75: G1-G6 & Fn1 Substitution String Setting

    G1-G6 & FN1 substitution string setting Format of barcode data transmission Prefix Code name Preamble Code ID Code length Code data Code ID Postamble Suffix Suffix string setting: The <enter > key is represented in different ASCII when it is applied by different OS. For a Windows/DOS OS, <enter>...
  • Page 76 Testing barcode: FN1 substitution string setting: The FN1 character (0x1D) in an UCC/EAN128 barcode, or a Code 128 barcode, or a GS1 DataBar barcode can be substituted with a defined string. Truncate leading G5 string setting: By setting, a defined leading character or string can be truncated. Also a single character can be un-defined.
  • Page 77 Testing barcode: Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Prefix string setting 0-22 characters 00-FF None 0-22 characters 00-FF Suffix string setting <ENTER> 0D0A* 0-22 characters 00-FF Preamble string setting None 0-22 characters 00-FF Postamble string setting None Insert G1 string setting 0-22 characters...
  • Page 78 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry <SP> A un-defined character Truncate leading G5 string setting 1-22 defined characters 01-7F <0> Once Repeat of a G5 character setting Defined times 01-22 Un-defined times (All) A un-defined character Truncate ending G6 string setting 1-22 defined characters 01-7F...
  • Page 79: G1-G4 String Position & Code Id Position

    G1-G4 string position & Code ID position Format of barcode data transmission Prefix Code name Preamble Code ID Code length Code data Code ID Postamble Suffix Insert G1/G2/G3/G4 string position: The scanner offers 4 positions to insert strings among the symbol. In case of the insertion position is greater than the length of the symbol, the insertion of string is not effective.
  • Page 80: String Transmission

    String transmission Note: The information in this chapter is closely related to the chapter of String setting. Format of barcode data transmission Prefix Code name Preamble Code ID Code length Code data Code ID Postamble Suffix Prefix transmission: By setting Enable, prefix will be appended before the data transmitted. Suffix transmission: By setting Enable, suffix will be appended after the data is transmitted.
  • Page 81 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Prefix transmission Disable Enable Disable Suffix transmission Enable Disable Code name transmission Enable Preamble transmission Disable Enable Disable Postamble transmission Enable Disable Code ID transmission Proprietary ID AIM ID Code length transmission Disable Enable Disable...
  • Page 82 Multiple-scan setting Single-scan setting Option bar code Option Alpha. entry Keyboard wedge/USB RS-232 Keyboard wedge / USB / RS-232 All-non-printable-character string Disable transmission with string setting Enable Transmit the first N data characters only 01-99 Transmit the last N data characters only 01-99...
  • Page 83: Test Chart

    Test Chart UPC-A UPC-E EAN-8 EAN-13 Code 39 Code 32 A908765439 Code 128 Interleaved 2 of 5 Industrial 2 of 5 (Default setting: Read disable) Matrix 2 of 5 Code 93...
  • Page 84 Test Chart (Continued) UCC/EAN 128 Code 11 (Default setting: Read disable) MSI/Plessey (Default setting: Read disable) UK/Plessey ISBN/ISSN China Post GS1 DataBar (GS1 DataBar Truncated) GS1 DataBar Limited GS1 DataBar Expanded...
  • Page 85 Test Chart (Continued) PDF417 12=890ab-+%xyz MicroPDF417 23+-mdo QR code 1234567890ABCD-+()&*%^@#$!XYZ Data Matrix 123890abc-+=&*%^!mdo...
  • Page 86 Maintenance Cleaning the exit window is the only maintenance required. A dirty window may affect scanning accuracy. Do not allow any abrasive material to touch the window. Remove any dirt particles with a damp cloth. Wipe the window using a tissue moistened with water. Do not spray water or other cleaning liquids directly into the window.
  • Page 87: Ascii Table

    ASCII Table for keyboard wedge for RS-232 Null Down Left Right PgUp PgDn Home Enter Insert Ctrl+ Delete Alt+ Notes: The 2nd and the 3rd columns above are used for keyboard wedge only. “ & „ < > Example: ASCII “A” = “41”.
  • Page 88: Barcode Representing Non-Printable Character

    Barcode representing non-printable character Notes to make the following barcode: 1. According to different barcode printing software, the method of printing following barcode is different. 2. If using CODESOFT software, firstly read the information through “Help→Index→Code128→Special input syntax”. Also refer to ASCII table. For example, if we wish to make “F1” barcode, select “code128”, then select “CODE A”...
  • Page 89: Return Default Parameters & Others

    Return default parameters & others WARNING: Default value initialization If you wish to return the scanner to all the factory default settings, scan the barcode above. Firmware version list If you wish to display the firmware version, scan the barcode above.
  • Page 90: Configuration Alphanumeric Entry Barcode

    Configuration alphanumeric entry barcode...