The 2916P Keypad Indoor/Outdoor Keypad is a surface-mount digital
keyless entry system designed for access control applications. The backlit
keys are bright and easy-to-read. A heavy cast vandal resistant housing
design with mounting plate allows the 2916P to be mounted on a rugged
surface or on a standard single-gang electrical box.
The 2916P has a capacity of 500 users. Users can be assigned to use 4 to
6 digit PIN codes and/or HID 125kHz proximity access credentials. An
authenticated access can be programmed to activate one or both of the
relay outputs.
The timed "anti-passback" feature prevents using the same credentials
twice before a programmed waiting period has elapsed.
Two long lasting solid state LED indicators show the status of the system.
The left bi-color indicator lights red to indicate power, then green when a
relay is active (access grant, etc.). The right indicator flashes yellow to
indicate that the keypad is in programming mode.
An internal sounder can be programmed to beep each time a key is
pressed or when an output is activated. An internal jumper sets the
sounder volume high or low.
The SENSE input can be configured two ways through programming .
When configured for "Door Sense", the input is wired to a normally closed
door position switch to detect when the door is opened or closed. Forced
entry or door ajar situations can then be detected. The "Auto-relock" feature
can also be used to turn off the Main Relay output immediately when the
door is closed after access has been granted to prevent "tailgating".
When the SENSE input is configured for "Inhibit", the input can be wired to
a normally open "service" switch or automatic timer that will disable access
while the switch is closed.
The REQUEST-TO-EXIT input can be wired to a normally open pushbutton
to provide codeless activation of the Main Relay, Auxiliary Relay, Output #3
or Output #4 (programmable).
The ALARM SHUNT signal is available when access is granted. This
signal can be programmed to activate any of the relays or solid state
outputs to shunt alarm contacts on the access door/gate preventing the
triggering of an alarm when an authorized access occurs.
The 2916P is powered from a 12 or 24V AC or DC source. The non-volatile
EEPROM memory retains entry codes and programming when power is
removed. An internal jumper is provided to reset the master code. The
Main Relay has a 5 Amp capacity. The Auxiliary Relay has a 2 Amp
capacity. Two solid state outputs, capable of sinking 100 mA to common
are programmable for alarm shunting, or to signal forced entry, door ajar,
keypad lockout, request-to-exit, and keypad active conditions.
Rev 6, Rev Date: 5/29/19
INSTALLATION INSTRUCTIONS
2916P Keypad
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995
2916P Proximity Keypad
Installation Instructions
Features
Keypad programmable
500 user codes
3 User Modes
PIN or Card
Card Only
Card and PIN
4 to 6 digit user codes
4 independent outputs
4 independent timers
2 Form C relay contacts
2 solid state open collector outputs
Program entry codes to activate one or
two relays
Disable input
Door sense input
Request-to-exit/Reception input
Keypad tamper lockout
Timed anti-passback
Anti-tailgate
Two LED status indicators
Tactile key feel
Audible code entry verification
12V or 24V, AC or DC operation
SPECIFICATIONS
Mechanical
Dimensions: 3.00" W x 5.75" H x 1.375" D
(1.4375" wall projection)
Electrical
Input Voltage: 12/24 Volts AC or DC
Operating Current: 30 mA typical, 150 mA max
Output Ratings
Main Relay: Form "C" 5 Amps @ 28 Volts max
Auxiliary Relay: Form "C" 2 Amp @ 28 Volts max
Type: Solid state outputs (Outputs #3 & #4)
Short-to-common 100 mA @ 24 VDC maximum
Environmental
Temperature: -4°F to 140°F (-20°C to 60°C)
Humidity: 5% to 95% non-condensing
I-EA00130
Page 1 of 8

Advertisement

Table of Contents
loading

Summary of Contents for hager 2916P

  • Page 1 2916P to be mounted on a rugged surface or on a standard single-gang electrical box. The 2916P has a capacity of 500 users. Users can be assigned to use 4 to 6 digit PIN codes and/or HID 125kHz proximity access credentials. An authenticated access can be programmed to activate one or both of the relay outputs.
  • Page 2 QuickStart Programming You must first enter programming mode to perform any function. The yellow indicator will blink slowly showing that the 2916P is in programming mode. Use the option codes to program each function. After the new data entry is complete for each function , the yellow indicator will flash quickly while the data is being stored and the green indicator will light briefly if the programming has been accepted.
  • Page 3: Keypad Wiring

    See fig. 5 for wiring examples using the solid Fig. 5 Using Solid State Outputs state outputs. Always visit www.hagerco.com for the latest Installation Instructions Page 3 of 8 Rev 6, Rev Date: 5/29/19 HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995...
  • Page 4: Factory Defaults

    Note: Leading zeros (zeros before the code number, i.e.0001) do not yellow indicator will flash rapidly while the keypad is waiting for need to be entered when programming a new code. The 2916P will user input data. The green indicator will light if the data is internally add any zeros to fill digits determined by the entry code length accepted.
  • Page 5 Output=Output to Activate (0-4) 1=Main Relay; 2 = Auxiliary Relay; 3=Output #3; 4=Output #4; The yellow indicator will flash quickly while the 2916P erases the 0=No Output / Lockout Disable user from memory. The green indicator will light when the code is erased.
  • Page 6: Resetting Keypad

    Sound=1 for Yes, =0 for No THE MASTER PROGRAMMING CODE IS NOW 123456. Always visit www.hagerco.com for the latest Installation Instructions Page 6 of 8 Rev 6, Rev Date: 5/29/19 HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995...
  • Page 7: Surface Mount

    MOUNTING TO SINGLE GANG RECESSED OUTLET BOX Mount at slots Always visit www.hagerco.com for the latest Installation Instructions Page 7 of 8 Rev 6, Rev Date: 5/29/19 HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995...
  • Page 8 Part #2-679-0669 4" POST MOUNT (WITH SHROUD) 4" Mount at holes Always visit www.hagerco.com for the latest Installation Instructions Page 8 of 8 Rev 6, Rev Date: 5/29/19 HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995...

Table of Contents